IBM System x3500M5-5464D2A



File chi tiết
Product ID: 5464D2A

Original description: x3500 M5, Xeon 8C E5-2630v3 85W 2.4GHz/1866MHz/20MB, 16GB, O/Bay HS 2.5in SATA/SAS, SR M1215 (ServeRAID 0, 1, 10), DVD-ROM, 550W p/s, Tower 5U, Keyboard, Mouse, Warranty 36 months.



Kho: Đặt hàng

Giá sản phẩm: 62.900.000 VNĐ

* Giá trên chưa bao gồm VAT *

Số lượng  



Components
Specification
Form factor
Tower or 5U Rack.
Processor
Xeon 8C E5-2630v3 85W 2.4GHz/1866MHz/20MB/ Up to two 18-core Intel Xeon processors E5-2600 v3 series
Cache
Up to 45 MB per processor
Memory (Max)
16GB TruDDR4 Memory (1Rx4, 1.2V) PC4-17000 CL15 2133MHz LP RDIMM/ Up to 1.5 TB with 64 GB* TruDDR4 Memory LRDIMMs.
Disk drive bays
Up to 32 2.5-inch hot-swap hard disk drives (HDDs) or solid-state drives (SSDs), or up to 12 3.5-inch hot-swap HDDs or 6 3.5-inch simple-swap HDDs, or a combination of up to 16 2.5-inch hot-swap HDDs/SSDs with up to 6 3.5-inch hot-swap HDDs
Maximum internal storage
72 TB with 12x 6TB 3.5-inch NL SAS or NL SATA hot-swap HDDs
51.2 TB with 32x 1.6TB 2.5-inch SAS hot-swap SSDs
38.4 TB with 32x 1.2TB 2.5-inch SAS hot-swap HDDs
36 TB with 6x 6TB 3.5-inch NL SAS or NL SATA simple-swap HDDs
Intermix of SAS and SATA is supported.
RAID Support
IBM ServeRAID M1215 RAID/ 12 Gbps hardware dual RAID adapters -0, -1, -10 with optional RAID-5, -50, -6, -60 upgrades
Optical drive bays
Two half-height 5.25-inch bays for optical or tape drives. Supports DVD-ROM or Multiburner.
Tape drive bays
Two half-height 5.25-inch bays for optical or tape drives. Support for one RDX internal USB tape drive.
Network interfaces
Quad-port Gigabit Ethernet and single-port IMM standard; optional 10 GbE PCIe adapters available
PCI Expansion slots
Up to seven PCIe 3.0 expansion slots; support for up to two 300 W GPUs
Power supply
1/2 PS Redundant 550 W AC/ hot-swap redundant 550 W/750 W/900 W, 80 PLUS Platinum or 750 W 80 PLUS Titanium
Hot-swap parts
Hard drives, power supplies, and fans
Systems management
IMM2 with dedicated management port (optional remote presence); Predictive Failure Analysis, Diagnostic LEDs, light path diagnostics, IBM Systems Director and IBM Systems Director Active Energy Manager
Security features
Power-on password, administrator's password, two TPMs: On the IMM2.1 (TPM 1.2) and on the host (TPM 1.2/2.0). Lockable front bezel.
Operating systems supported
Microsoft Windows Server , Red Hat Enterprise Linux, SUSE Linux Enterprise, VMware vSphere - (Optional USB Key or SD Media Adapter*)
Limited warranty
3-year customer replaceable unit and onsite limited warranty, next business day 9x5, service upgrades available

Introduction


The Lenovo System x3500 M5 server provides outstanding performance for your business-critical applications. Its energy-efficient design supports more cores, memory, and data capacity in a scalable Tower or 5U Rack package that is easy to service and manage. With more computing power per watt and the latest Intel Xeon E5-2600 v3 processors, you can reduce costs while maintaining speed and availability.

Suggested use: business-critical workloads, cloud computing, virtualization, virtual desktop, big data, analytics, SAP applications, database management, point of sale

Figure 1 shows the System x3500 M5.


Figure 1. The Lenovo System x3500 M5

Did you know?

The x3500 M5 offers a flexible, scalable design and simple upgrade path to 32 HDDs, with up to seven PCIe 3.0 slots and up to 1.5 TB of memory. The onboard Ethernet solution provides four standard integrated Gigabit Ethernet ports without occupying PCIe slots. Comprehensive systems management tools with the next-generation Integrated Management Module II make it easy to deploy, integrate, service, and manage.

Key features

A high-performance dual-socket tower server, the Lenovo System x3500 M5 can deliver the scalability, reliable performance, and optimized efficiency for your business-critical applications. Start with the basics and upgrade as your business changes without jeopardizing existing investments. Virtualizing the PC infrastructure into one server can provide access to a powerful server with abundant storage space, while significantly reducing IT costs.

Scalability and performance

The x3500 M5 offers the following features to boost performance, improve scalability, and reduce costs:

  • Improves productivity by offering superior system performance with up to two processors (each with up to 18 cores), up to 45 MB of L3 cache, and up to 9.6 GT/s QPI interconnect links.
  • Supports up to two processors, 36 cores, and 72 threads maximize the concurrent execution of multi-threaded applications.
  • Intelligent and adaptive system performance with energy efficient Intel Turbo Boost Technology allows CPU cores to run at maximum speeds during peak workloads by temporarily going beyond processor thermal design power (TDP).
  • Intel Hyper-Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core, up to two threads per core.
  • Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads.
  • Intel Advanced Vector Extensions 2.0 (AVX 2.0) enable acceleration of enterprise-class workloads, including databases, and enterprise resource planning.
  • Up to 2133 MHz memory speeds with two DIMMs per channel that are running at 2133 MHz to help maximize system performance.
  • Up to 1.5 TB of memory capacity with 64 GB load-reduced DIMMs, or LRDIMMs (support for 64 GB LRDIMMs is planned for a later date).
  • The 12 Gbps SAS internal storage connectivity doubles the data transfer rate compared to 6 Gb SAS solutions to maximize performance of storage I/O-intensive applications.
  • Up to 32 drive bays with internal backup and optical drive at the same time provide a flexible and scalable all-in-one platform to meet increasing demands.
  • Flexible and scalable internal storage configurations provide for up to 72 TB of storage capacity.
  • The use of solid-state drives (SSDs) instead of or along with traditional spinning hard disk drives (HDDs) can significantly improve I/O performance. An SSD can support up to 100 times more I/O operations per second (IOPS) than a typical HDD.
  • The server has four integrated Gigabit Ethernet ports.
  • The server offers up to seven PCI Express (PCIe) 3.0 I/O expansion slots.
  • With Intel Integrated I/O Technology, the PCI Express 3.0 controller is integrated into the Intel Xeon processor E5 family. This integration helps to dramatically reduce I/O latency and increase overall system performance.
  • Support for up to two NVIDIA Quadro graphics processing units (GPUs) to maximize computing power.


Availability and serviceability

The x3500 M5 provides the following features to simplify serviceability and increase system uptime:

  • The server offers Chipkill, memory mirroring, and memory rank sparing for redundancy in the event of a non-correctable memory failure.
  • Tool-less cover removal provides easy access to upgrades and serviceable parts, such as CPU, memory, and adapter cards.
  • Offers hot-swap drives that support RAID redundancy for data protection and greater system uptime.
  • Supports the ability to have redundant hot-swap power supplies and redundant hot-swap fans to provide availability for business-critical applications.
  • The optional light path diagnostics panel and individual light path LEDs quickly lead the technician to failed (or failing) components. This feature simplifies servicing, speeds up problem resolution, and helps improve system availability.
  • Predictive Failure Analysis (PFA) detects when system components (processors, VRMs, memory, disks, fans, and power supplies) operate outside of standard thresholds and generates proactive alerts in advance of possible failure, which increases uptime.
  • SSDs offer significantly better reliability than traditional mechanical HDDs for greater uptime.
  • Built-in Integrated Management Module II (IMM2.1) continuously monitors system parameters, triggers alerts, and performs recovery actions if there is a failure to minimize downtime.
  • Built-in diagnostics by using Dynamic Systems Analysis (DSA) Preboot speeds up troubleshooting tasks to reduce service time.
  • Three-year customer replaceable unit and onsite limited warranty; next business day 9x5. Optional service upgrades available.


Manageability and security

The following powerful systems management features simplify local and remote management of the x3500 M5:

  • The server includes an IMM2.1 to monitor server availability and perform remote management.
  • Integrated industry-standard Unified Extensible Firmware Interface (UEFI) enables improved setup, configuration, and updates and simplifies error handling.
  • Two integrated Trusted Platform Modules (TPMs) enable advanced cryptographic functionality, such as digital signatures and remote attestation.
  • System x Trusted Platform Assurance, an exclusive set of System x security features and practices, establishes a foolproof security foundation for workloads by delivering firmware that is securely built, tested, digitally signed, and verified before running.
  • The server offers enterprise-class data protection with optional self-encrypting drives and simple, centralized key management through IBM Security Key Lifecycle Management.
  • Industry-standard AES NI support offers faster, stronger encryption.
  • IBM Systems Director offers comprehensive systems management tools that help to increase uptime, reduce costs, and improve productivity through advanced server management capabilities.
  • Intel Execute Disable Bit functionality can help prevent certain classes of malicious buffer overflow attacks when combined with a supporting operating system.
  • Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, which allows an application to run in its own isolated space that is protected from all other software running on a system.


Energy efficiency

The x3500 M5 offers the following energy-efficiency features to save energy, reduce operational costs, increase energy availability, and contribute to the green environment:

  • Energy-efficient planar components help lower operational costs.
  • High-efficiency power supplies with 80 PLUS Platinum and Titanium certifications.
  • Intel Intelligent Power Capability powers individual processor elements on and off as needed to reduce power draw.
  • The Intel Xeon processor E5-2600 v3 product families offer significantly better performance over the previous generation while fitting into the same thermal design power (TDP) limits.
  • Intel Intelligent Power Capability powers individual processor elements on and off as needed to reduce power draw.
  • Low-voltage Intel Xeon processors draw less energy to satisfy demands of power and thermally constrained data centers and telecommunication environments.
  • Low-voltage 1.2 V DDR4 memory DIMMs use up to 20% less energy compared to 1.35 V DDR3 DIMMs.
  • SSDs use as much as 80% less power than traditional spinning 2.5-inch HDDs.
  • The server uses hexagonal ventilation holes, which is a part of Calibrated Vectored Cooling™ technology. Hexagonal holes can be grouped more densely than round holes, which provides more efficient airflow through the system.
  • IBM Systems Director Active Energy Manager™ provides advanced data center power notification and management to help achieve lower heat output and reduced cooling needs.

 

Locations of key components and connectors

The following figure shows the front of the server.


Figure 2. Front view of the System x3500 M5

The following figure shows the rear of the server.


Figure 3. Rear view of the System x3500 M5

The following figure shows the locations of key components inside the server.


Figure 4. Inside view of the System x3500 M5

Standard specifications

The following table lists the standard specifications.

Table 1. Standard specifications

Components Specification
Machine type 5464
Form factor Tower or 5U Rack.
Processor Up to two Intel Xeon processor E5-2600 v3 product family CPUs with 18 cores (2.8 GHz core speeds); or 14 cores (2.6 GHz), 12 cores (up to 2.6 GHz), 10 cores (2.3 GHz), 8 cores (up to 3.2 GHz), 6 cores (up to 2.4 GHz), 4 cores (3.0 GHz)
Two QPI links up to 9.6 GT/s each. Up to 2133 MHz memory speed. Up to 45 MB L3 cache.
Chipset Intel C612.
Memory Up to 24 DIMM sockets (12 DIMMs per processor). RDIMMs and LRDIMMs are supported. Memory types cannot be intermixed. Memory speed up to 2133 MHz.
Memory maximums With RDIMMs: Up to 384 GB with 24x 16 GB RDIMMs and two processors
With LRDIMMs: Up to 1.5 TB with 24x 64 GB LRDIMMs and two processors
Memory protection ECC, Chipkill (for x4-based memory DIMMs), memory mirroring, and memory rank sparing
Disk drive bays Available configurations:
  • Up to 32x 2.5-inch hot-swap SAS/SATA HDDs
  • Up to 12x 3.5-inch hot-swap SAS/SATA HDDs or SSDs
  • Up to 6x 3.5-inch hot-swap HDDs + 16x 2.5-inch hot-swap drives HDDs/SSDs
  • Up to 6x 3.5-inch simple-swap SATA HDDs
Additional drive bays for the above configurations:
  • Two 5.25-inch drive bays for optical drives
Maximum internal storage
  • 72 TB with 12x 6TB 3.5-inch NL SAS or NL SATA hot-swap HDDs
  • 51.2 TB with 32x 1.6TB 2.5-inch SAS hot-swap SSDs
  • 38.4 TB with 32x 1.2TB 2.5-inch SAS hot-swap HDDs
  • 36 TB with 6x 6TB 3.5-inch NL SAS or NL SATA simple-swap HDDs
  • Intermix of SAS and SATA is supported.
Storage controller
  • Onboard 6 Gb SATA: no RAID support
  • 12 Gb SAS/SATA RAID: RAID 0, 1, 10 with M1215 or M5210. Optional upgrade to RAID 5, 50 is available for M1215. Optional upgrade to RAID 5, 50 is available for M5210 (zero-cache; 1 GB non-backed cache; 1 GB, 2 GB or 4 GB flash-backed cache). Optional upgrade to RAID 6, 60 is available for M5210 with memory cache upgrades.
  • 12 Gb SAS/SATA non-RAID: N2215 HBA
Optical drive bays Two half-height 5.25-inch bays for optical or tape drives. Supports DVD-ROM or Multiburner.
Tape drive bays Two half-height 5.25-inch bays for optical or tape drives. Support for one RDX internal USB tape drive.
Network interfaces Four integrated Gigabit Ethernet 1000BASE-T ports (RJ-45) based on Broadcom BCM5719 controller
PCI Expansion slots Up to seven slots with two processors and four slots when one CPU is installed. All slots are PCIe 3.0 slots:
  • Slot 1: PCIe 3.0 x8 (x8 wired); full-height, half-length
  • Slot 2: PCIe 3.0 x16 (x8 wired); full-height, full-length
  • Slot 3: PCIe 3.0 x16 (x16 wired); full-height, full-length
  • Slot 4: PCIe 3.0 x8 (x8 wired); full-height, full-length
  • Slot 5: PCIe 3.0 x8 (x8 wired); full-height, half-length (requires second processor)
  • Slot 6: PCIe 3.0 x16 (x16 wired); full-height, full-length (requires second processor)
  • Slot 7: PCIe 3.0 x16 (x16 wired) full-height, full-length (requires second processor)
Slots 3 and 6 support double-wide GPUs
Ports
  • Front: Two USB 2.0 ports
  • Rear: Four USB ports (two USB 2.0, two USB 3.0), one DB-15 video, one RJ-45 systems management, four RJ-45 GbE network ports, optional serial port.
  • Internal: Two internal USB 3.0 ports (for embedded hypervisor and internal tape drive). Optional SD Media Adapter.
Cooling Calibrated Vectored Cooling with up to four hot-swap fans (two fans shipped standard on single processor models and four fans shipped on dual processor models). For single-processor models, optional Redundant Cooling Kit provides two extra fans for N+1 redundancy.
Power supply Up to two redundant hot-swap 550 W, 750 W or 900 W High Efficiency Platinum AC power supplies, or 750 W High Efficiency Titanium AC power supplies.
Hot-swap parts Hard drives, power supplies, and fans
Systems management UEFI, IMM2.1 that is based on Renesas SH7758, Predictive Failure Analysis, light path diagnostics panel on the front of the server with optional upgrade kit, Automatic Server Restart, ToolsCenter, Systems Director and Active Energy Manager. Optional IMM Advanced Upgrade software feature for remote presence.
Security features Power-on password, administrator's password, two TPMs: On the IMM2.1 (TPM 1.2) and on the host (TPM 1.2/2.0). Lockable front bezel.
Video Matrox G200eR2 with 16 MB memory integrated into the IMM2.1. Maximum resolution is 1600x1200 at 75 Hz with 16 M colors.
Operating systems supported Microsoft Windows Server 2012 R2, 2012 and 2008 R2, Red Hat Enterprise Linux 6 and 7, SUSE Linux Enterprise Server 11, VMware vSphere (ESXi) 5.1 and 5.5.
Limited warranty Three-year customer-replaceable unit and onsite limited warranty with 9x5/NBD.
Service and support Optional service upgrades are available through Lenovo: 4-hour or 2-hour response time, 8-hour fix time, 1-year or 2-year warranty extension, remote technical support for Lenovo hardware and selected Lenovo and third-party (Microsoft, Linux, VMware) software.
Dimensions Tower: Width: 218 mm (8.6 in), depth: 720 mm (28.3 in), height: 440 mm (17.25 in).
With rack conversion kit: Width: 423 mm (16.6 in), depth: 706 mm (27.8 in), height: 218 mm (8.6 in )
Weight Tower: 45.5 kg (100.3 lb) fully configured, 30.8 kg (67.9 lb) minimum configuration
With rack conversion kit: 44.2 kg (97.4 lb) fully configured, 29.5 kg (65 lb) minimum configuration


The x3500 M5 servers are shipped with the following items:

  • Statement of Limited Warranty
  • Important Notices
  • Registration flyer
  • Documentation CD that contains the Installation and User's Guide
  • One 2.8 m C13 line cord (country-specific)


Notes:

  • Rack models include a rail kit but do not include a cable management arm. Order the CMA separately by using part number 00KC334.
  • EMEA models do not contain line cord. It must be purchased separately.

Standard models

The following table lists the standard models.

Table 2. Standard models

MTM* Intel Xeon processors†
(two maximum)
Memory RAID Drive bays
(std / max)
Drives Slots
(std /

max)
GbE Optical Power
supply
(std / max)
Tower models
5464-
A2x
1x E5-2603 v3 6C 1.6GHz
15MB 1600MHz 85W
1x 8 GB M1215 8x 2.5-inch
HS / 32
Open 4 / 7 4 DVD 1x 550 W
HS / 2
5464-
B2x
1x E5-2609 v3 6C 1.9GHz
15MB 1600MHz 85W
1x 8 GB M1215 8x 2.5-inch
HS / 32
Open 4 / 7 4 DVD 1x 550 W
HS / 2
5464-
C2x
1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W
1x 16 GB M1215 8x 2.5-inch
HS / 32
Open 4 / 7 4 DVD 1x 550 W
HS / 2
5464-
C4x
1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W
1x 16 GB M1215 6x 3.5-inch
HS / 12
Open 4 / 7 4 DVD 1x 550 W
HS / 2
5464-
D2x
1x E5-2630 v3 8C 2.4GHz
20MB 1866MHz 85W
1x 16 GB M1215 8x 2.5-inch
HS / 32
Open 4 / 7 4 DVD 1x 550 W
HS / 2
5464-
G2x
1x E5-2650 v3 10C 2.3GHz
25MB 2133MHz 105W
1x 16 GB M5210 1GB
Flash
8x 2.-inch
HS / 32
Open 4 / 7 4 DVD 1x 750 W
HS / 2
5464-
H2x
1x E5-2670 v3 12C 2.3GHz
30MB 2133MHz 120W
1x 16 GB M5210 2GB
Flash
8x 2.5-inch
HS / 32
Open 4 / 7 4 DVD 1x 900 W
HS / 2
5464-
J2x
1x E5-2680 v3 12C 2.5GHz
30MB 2133MHz 120W
1x 16 GB M5210 2GB
Flash
8x 2.5-inch
HS / 32
Open 4 / 7 4 DVD 1x 900 W
HS / 2
Rack models
5464-
C3x
1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W
1x 16 GB M1215 6x 3.5-inch
HS / 12
Open 4 / 7 4 DVD 1x 550 W
HS / 2
5464-
G3x
1x E5-2650 v3 10C 2.3GHz
25MB 2133MHz 105W
1x 16 GB M5210 1GB
Flash
8x 2.5-inch
HS / 32
Open 4 / 7 4 DVD 1x 750 W
HS / 2

* x in the Machine Type Model (MTM) represents a country-specific letter (for example, the EMEA MTM is 7983-A5G, and the US MTM is 7383-A5U). Ask a Lenovo representative for specific information.
† Processor detail: Processor quantity and model, cores, core speed, L3 cache, memory speed, TDP.

Refer to the Specifications section for information about standard features of the server.

TopSeller and Express models

The following table lists the express models.

Table 3. Express models

MTM**
Form
factor
Intel Xeon processors†
(two maximum)
Memory RAID Drive
bays
(std / max)
Drives Slots
(std /

max)
Optical Power
supply
(2 max)
United States and Canada
5464-EAU
Tower
1x E5-2609 v3 6C 1.9GHz
15MB 1600MHz 85W
1x 8 GB M1215 6x 3.5-inch
HS / 12
Open 4 / 7 Multi-
burner
1x 550W
5464-EBU
Tower
1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W
1x 16 GB M5120 6x 3.5-inch
HS / 12
Open 4 / 7 Multi-
burner
1x 750W
5464-ECU
Tower
1x E5-2640 v3 8C 2.6GHz
20MB 1866MHz 90W
1x 16 GB M5120 8x 2.5-inch
HS / 32
Open 4 / 7 Multi-
burner
1x 750W
5464-EDU
Tower
2x E5-2609 v3 6C 1.9GHz
15MB 1600MHz 85W
2x 16 GB M5120 2GB
Flash
6x 3.5-inch
HS / 12
Open 4 / 7 Multi-
burner
2x 550W
5464-EEU
Tower
2x E5-2640 v3 8C 2.6GHz
20MB 1866MHz 90W
2x 16 GB M5120 2GB
Flash
8x 2.5-inch
HS / 32
Open 4 / 7 Multi-
burner
2x 750W
Europe, Middle East & Africa (EMEA)
5464-E1G
Tower
1x E5-2603 v3 6C 1.6GHz
15MB 1600MHz 85W
M1215 +
RAID 5/50
8x 2.5-inch
HS / 32
Open 4 / 7 Multi-
burner
1x 550W
5464-E2G
Tower
1x E5-2609 v3 6C 1.9GHz
15MB 1600MHz 85W
1x 8 GB M1215 +
RAID 5/50
6x 3.5-inch
HS / 12
Open 4 / 7 Multi-
burner
1x 550W
5464-E3G
Tower
1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W
1x 8 GB M5120 1GB
No backup
8x 2.5-inch
HS / 32
Open 4 / 7 Multi-
burner
2x 550W
5464-E4G
Tower
1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W
1x 8 GB M5120 1GB
Flash
8x 2.5-inch
HS / 32
3x 300GB
10K SAS
4 / 7 Multi-
burner
2x 750W
5464-E5G
Tower
1x E5-2640 v3 8C 2.6GHz
20MB 1866MHz 90W
1x 16 GB M5120 2GB
Flash
8x 2.5-inch
HS / 32
Open 4 / 7 Multi-
burner
2x 750W
Latin America & Brazil
5464-EFx
Tower
1x E5-2609 v3 6C 1.9GHz
15MB 1600MHz 85W
1x 8 GB M5120 1GB
Flash+Cap
8x 2.5-inch
HS / 32
Open 4 / 7 DVD 1x 550W
5464-EGx
Tower
1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W
1x 16 GB M5120 1GB
Flash
8x 2.5-inch
HS / 32
Open 4 / 7 DVD 1x 550W
5464-EHx
Tower
1x E5-2650 v3 10C 2.3GHz
25MB 2133MHz 105W
1x 16 GB M5120 1GB
Flash
8x 2.5-inch
HS / 32
Open 4 / 7 DVD 1x 750W
Japan
5464-E6J
Tower
1x E5-2603 v3 6C 1.6GHz
15MB 1600MHz 85W
1x 8 GB M5120 1GB
Flash
8x 2.5-inch
HS / 32
Open 4 / 7 DVD 1x 550W
5464-E7J
Tower
1x E5-2609 v3 6C 1.9GHz
15MB 1600MHz 85W
1x 8 GB M5120 1GB
Flash
8x 2.5-inch
HS / 32
Open 4 / 7 DVD 1x 550W
Australia & New Zealand
5464-EIM
Tower
1x E5-2609 v3 6C 1.9GHz
15MB 1600MHz 85W
1x 8 GB M1215 +
RAID 5/50
6x 3.5-inch
HS / 12
Open 4 / 7 Multi-
burner
1x 550W
5464-EJM
Tower
1x E5-2609 v3 6C 1.9GHz
15MB 1600MHz 85W
1x 8 GB M1215 +
RAID 5/50
8x 2.5-inch
HS / 32
Open 4 / 7 Multi-
burner
1x 550W
5464-EKM
Tower
1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W
2x 8 GB M5120 1GB
Flash+Cap
8x 2.5-inch
HS / 32
Open 4 / 7 Multi-
burner
1x 550W
5464-ELM
Tower
1x E5-2640 v3 8C 2.6GHz
20MB 1866MHz 90W
2x 8 GB M5120 1GB
Flash+Cap
8x 2.5-inch
HS / 32
Open 4 / 7 Multi-
burner
1x 750W

** MTM = Machine Type Model
† Processor detail: Processor quantity and model, number of cores, core speed, L3 cache, memory speed, TDP.

Table 4. TopSeller Models

MTM**
Form
factor
Intel Xeon processors†
(two maximum)
Memory RAID Drive
bays
(std / max)
Drives Slots
(std /

max)
Optical Power
supply
(2 max)
United States and Canada
5464-NAY
Tower
1x E5-2603 v3 6C 1.6GHz
15MB 1600MHz 85W
1x 8 GB M1215 6x 3.5-inch
HS / 12
Open 4 / 7 Open 1x 550W
5464-NBY
Tower
1x E5-2609 v3 6C 1.9GHz
15MB 1600MHz 85W
1x 8 GB M1215 8x 2.5-inch
HS / 32
Open 4 / 7 Open 1x 550W
5464-NCY
Tower
1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W
1x 16 GB M1215 8x 2.5-inch
HS / 32
Open 4 / 7 Open 1x 550W
5464-NDY
Tower
1x E5-2630 v3 8C 2.4GHz
20MB 1866MHz 85W
1x 16 GB M5120 8x 2.5-inch
HS / 32
Open 4 / 7 Open 1x 550W
5464-NEY
Tower
1x E5-2630 v3 8C 2.4GHz
20MB 1866MHz 85W
1x 16 GB M5120 6x 3.5-inch
HS / 12
Open 4 / 7 Open 1x 550W
5464-NFY
Tower
1x E5-2650 v3 10C 2.3GHz
25MB 2133MHz 105W
1x 16 GB M5120 8x 2.5-inch
HS / 32
Open 4 / 7 Open 1x 750W
Europe, Middle East, and Africa (EMEA)
5464-K1G 1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W
1x 16 GB M5210 2GB
Flash
8x 2.5-inch
HS / 32
Open 4 / 7 Multi-
burner
1x 550W

 

Processor options

The x3500 M5 supports the processor options that are listed in the following table. The server supports up to two processors. This table shows which server models feature each processor as standard. If there is no corresponding where-used model for a particular processor, this processor is available through CTO only.

Table 5. Processor options

Part
number
Feature
codes*
Description Standard models
where used
81Y7113 A5C8 / A5MP Intel Xeon E5-2603 v3 6C 1.6GHz 15MB 1600MHz 85W A2x
81Y7114 A5C9 / A5MQ Intel Xeon E5-2609 v3 6C 1.9GHz 15MB 1600MHz 85W B2x
81Y7115 A5CA / A5MR Intel Xeon E5-2620 v3 6C 2.4GHz 15MB 1866MHz 85W C2x, C3x, C4x
00MU332 ASLW / ASLZ Intel Xeon E5-2623 v3 4C 3.0GHz 10MB 1866MHz 105W -
81Y7116 A5CB / A5MS Intel Xeon E5-2630 v3 8C 2.4GHz 20MB 1866MHz 85W D2x
00KG052 ARZK / ARZL Intel Xeon E5-2630L v3 8C 1.8GHz 20MB 1866MHz 55W -
81Y7117 A5CC / A5MT Intel Xeon E5-2640 v3 8C 2.6GHz 20MB 1866MHz 90W -
81Y7118 A5CD / A5MU Intel Xeon E5-2650 v3 10C 2.3GHz 25MB 2133MHz 105W G2x, G3x
81Y7121 A5CG / A5MX Intel Xeon E5-2650L v3 12C 1.8GHz 30MB 2133MHz 65W -
00MU330 ASLU / ASLX Intel Xeon E5-2660 v3 12C 2.3GHz 30MB 2133MHz 105W -
00MU331 ASLV / ASLY Intel Xeon E5-2667 v3 8C 3.2GHz 20MB 2133MHz 135W -
81Y7119 A5CE / A5MV Intel Xeon E5-2670 v3 12C 2.3GHz 30MB 2133MHz 120W H2x
81Y7120 A5CF / A5MW Intel Xeon E5-2680 v3 12C 2.5GHz 30MB 2133MHz 120W J2x
00KG038 ARYU / ARYX Intel Xeon E5-2690 v3 12C 2.6GHz 30MB 2133MHz 135W -
00KG039 ARYV / ARYY Intel Xeon E5-2697 v3 14C 2.6GHz 35MB 2133MHz 145W -
00KG040 ARYW / ARYZ Intel Xeon E5-2699 v3 18C 2.8GHz 45MB 2133MHz 145W -

* The first feature code is for the first processor; the second feature code is for the second processor.

Memory options

The System x3500 M5 supports TruDDR4 memory. TruDDR Memory uses the highest quality components that are sourced from Tier 1 DRAM suppliers and only memory that meets our strict requirements is selected. It is compatibility tested and tuned on every System x server to maximize performance and reliability. TruDDR4 Memory has a unique signature programmed into the DIMM that enables System x servers to verify whether the installed memory is qualified or supported. Because TruDDR4 Memory is authenticated, certain extended memory performance features can be enabled to extend performance over industry standards. From a service and support standpoint, System x memory automatically assumes the system's warranty, and service and support provided worldwide.

The following table lists the available memory options for the x3500 M5 server.

Table 6. Memory options

Part number Feature code Description Maximum supported Standard models
where used
RDIMMs - 2133 MHz
46W0784 A5B6 4GB TruDDR4 Memory (1Rx8, 1.2V) PC4-17000 CL15 2133MHz LP RDIMM 24 (12 per CPU) -
46W0788 A5B5 8GB TruDDR4 Memory (1Rx4, 1.2V) PC4-17000 CL15 2133MHz LP RDIMM 24 (12 per CPU) A2x, B2x
46W0792 A5B8 8GB TruDDR4 Memory (2Rx8, 1.2V) PC4-17000 CL15 2133MHz LP RDIMM 24 (12 per CPU)
46W0796 A5B7 16GB TruDDR4 Memory (2Rx4, 1.2V) PC4-17000 CL15 2133MHz LP RDIMM 24 (12 per CPU) All other models
LRDIMMs - 2133 MHz
46W0800 A5B9 32GB TruDDR4 Memory (4Rx4, 1.2V) PC417000 CL15 2133MHz LP LRDIMM 24 (12 per CPU) -
95Y4812* A5UK 64GB TruDDR4 Memory (4Rx4,1.2V) PC4-17000 CL15 2133MHz LP LRDIMM 24 (12 per CPU) -

* Support for 64 GB LRDIMMs is planned for a later date.

The server supports up to 12 DIMMs when one processor is installed and up to 24 DIMMs when two processors are installed. Each processor has four memory channels; there are three DIMMs per channel.

The following rules apply when the memory configuration is selected:

  • The server supports RDIMMs and LRDIMMs.
  • Mixing types of memory (RDIMMs and LRDIMMs) is not supported.
  • The maximum quantity of DIMMs that can be installed in the server depends on the number of processors.
  • All DIMMs in the server operate at the same speed, which is determined as the lowest value of the following factors:
    • Memory speed that is supported by the specific processor.
    • Lowest of maximum operating speeds for selected memory configuration that depends on quantity of DIMMs per channel, as shown under "Maximum operating speed" section in the following table.


The following memory protection technologies are supported:

  • ECC
  • Chipkill (for x4-based memory DIMMs)
  • Memory mirroring
  • Memory rank sparing


Chipkill works only in independent channel mode (the default is operational mode) and supports only x4-based memory DIMMs.

If memory mirroring is used, DIMMs must be installed in pairs (a minimum of one pair per each processor). Both DIMMs in a pair must be identical in type and size.

If memory rank sparing is used, a minimum of one quad-rank LRDIMM or two single-rank or dual-rank RDIMMs must be installed per populated channel (the DIMMs do not need to be identical). In rank sparing mode, one rank of a DIMM in each populated channel is reserved as spare memory. The size of a rank varies, depending on the DIMMs installed.

Chipkill, memory mirroring, and memory rank sparing modes are mutually exclusive. Only one operational memory mode can be enabled on a server, and it is a system-wide setting.

The following table shows the characteristics of the supported DIMMs. Tables cells that are highlighted with a gray background indicate when the number of DIMMs per channel still allows the DIMMs to operate at a rated speed.

Table 7. Maximum memory speeds

DIMM specification
RDIMM
LRDIMM
Rank
Single rank
Dual rank
Quad rank
Part numbers
46W0784 (4 GB)
46W0788 (8 GB)
46W0792 (8 GB)
46W0796 (16 GB)
46W0800 (32 GB)
95Y4812 (64 GB)*
Rated speed
2133 MHz
2133 MHz
2133 MHz
2133 MHz
Rated voltage
1.2 V
1.2 V
1.2 V
1.2 V
Maximum quantity supported**
24
24
24
24
Maximum DIMM capacity
8 GB
8 GB
16 GB
64 GB
Maximum memory capacity
192 GB
192 GB
384 GB
1.5 TB
Maximum memory at rated speed
64 GB
64 GB
256 GB
512 GB
Maximum operating speed
1 DIMM per channel
2133 MHz
2133 MHz
2133 MHz
2133 MHz
2 DIMMs per channel
2133 MHz
2133 MHz
2133 MHz
2133 MHz
3 DIMMs per channel
1600 MHz
1600 MHz
1600 MHz
1866 MHz

* Support for 64 GB LRDIMMs is planned for a later date.
** The maximum quantity that is supported is shown for two processors installed.

Internal storage

The internal drive bays of the x3500 M5 are shown in the following figure.


Figure 5. Internal drive bays

The System x3500 M5 server supports the following internal storage configurations:

  • Configurations with 2.5-inch hot-swap drives:
    • 8x 2.5-inch hot-swap drives (1 RAID adapter)
    • 16x 2.5-inch hot-swap drives (1 RAID adapter)
    • 16x 2.5-inch hot-swap drives (2 RAID adapters)
    • 24x 2.5-inch hot-swap drives (1 RAID adapter)
    • 24x 2.5-inch hot-swap drives (2 RAID adapters)
    • 32x 2.5-inch hot-swap drives (1 RAID adapter)
    • 32x 2.5-inch hot-swap drives (2 RAID adapters)
  • Configurations with 3.5-inch hot-swap drives:
    • 6x 3.5-inch hot-swap hard disk drives (1 RAID adapter)
    • 12x 3.5-inch hot-swap hard disk drives (2 RAID adapters)
  • Configurations with 2.5-inch and 3.5-inch hot-swap drives: 6x 3.5-inch hot-swap hard disk drives + 16x 2.5-inch hot-swap drives (2 RAID adapters)
  • Configurations with 3.5-inch simple-swap drives:
    • 6x 3.5-inch simple-swap hard disk drives (6 Gb SATA onboard connectors)
    • 6x 3.5-inch simple-swap hard disk drives (1 adapter)
    •  
    Note: A configuration of 12 simple-swap drives is not supported.


The following drive type mixing rules apply:

  • Hot-swap SATA HDDs and hot-swap SAS HDDs can be intermixed on the same backplane , but cannot be intermixed in the same RAID array.
  • Hot-swap SATA HDDs and hot-swap SAS HDDs can be intermixed with SSDs on the same backplane, but SAS nor SATA HDDs can be configured with SSDs within the same RAID array.



Backplanes

The following table lists the available backplanes for the x3500 M5. Standard models ship with one 8x 2.5-inch hot-swap backplane or one 6x 3.5-inch hot-swap backplane, as listed.

Table 8. Internal storage backplane (configure to order)

Feature
code
Name Models
where used
Maximum
supported
A5D4 System x3500 M5 2.5-inch Hot Swap SAS:
  • 8x 2.5-inch hot-swap drives
  • Connect to 1 adapter (2 ports) or 2 adapters (1 port each)
  • Supported by M5210, M1215, or N2215
All other
standard
models
2
A5N5 System x3500 M5 2.5-inch Hot Swap SAS 8-16:
  • 8x 2.5-inch hot-swap drives
  • Includes a SAS expander
  • Connects to backplane A5D4 to support up to 16 drives per port
  • Supported by M5210, M1215, or N2215
- 2
A5D5 System x3500 M5 3.5-inch Hot Swap SAS:
  • 6x 3.5-inch hot-swap drives
  • Supported by M5210, M1215, or N2215
C3x, C4x 2
A5UM System x3500 M5 3.5-inch Simple Swap:
  • 6x 3.5-inch simple-swap drives
  • Connections to onboard SATA ports
- 1
A5D2 System x3500 M5 3.5-inch Simple Swap:
  • 6x 3.5-inch simple-swap drives
  • Connections to RAID controller
- 1


The following table list the available hot-swap drive bay upgrades.

Table 9. Drive bay upgrade options

Option
part number
Name
00AL540 8x 2.5-inch Hot-Swap SAS/SATA Upgrade Kit for 16 or 24 HDDs:
  • For existing configurations with 8x or 16x 2.5-inch bays
  • Adds 8x 2.5-inch hot-swap drives
  • Backplane Includes a SAS expander
  • Same backplane as feature A5N5
00AL541 8x 2.5-inch Hot-Swap SAS/SATA Upgrade Kit for 32 HDDs:
  • For existing configurations with 24x 2.5-inch bays
  • Adds 8x 2.5-inch hot-swap drives
  • Same backplane as feature A5D4
00AL542 6x 3.5-inch Hot-Swap SAS/SATA Upgrade Kit for 12 HDDs:
  • For existing configurations with 6x 3.5-inch drives
  • Adds 6x 3.5-inch hot-swap drives
  • Same backplane as feature A5D5
00AL543 6x 3.5-inch Hot-Swap SAS/SATA Upgrade Kit for 22 HDDs (Intermix):
  • For existing configurations with 16x 2.5-inch drives
  • Adds 6x 3.5-inch hot-swap drives
  • Same backplane as feature A5D5
00AL544 8x 2.5-inch Hot-Swap SAS/SATA Upgrade Kit for 14 HDDs (Intermix):
  • For existing configurations with 6x 3.5-inch drives
  • Adds 8x 2.5-inch hot-swap drives
  • Same backplane as feature A5D4
00KG037 8x 2.5-inch Hot-Swap SAS/SATA Upgrade Kit for 22 HDDs (Intermix):
  • For existing configurations with 6x 3.5-inch and 8x 2.5-inch drives
  • Adds 8x 2.5-inch hot-swap drives
  • Same backplane as feature A5N5
00AL539 SAS cable option for Dual RAID array (RAID adapter not included):
  • For configurations with two RAID cards
  • Only needed when upgrading from 8x 2.5-inch drives to 16, 24 or 32 drives, as shown in Figure 7.
  • Connects second adapter to backplane


Drive bay configurations

The following figure shows how models with eight 2.5-inch drive bays can be upgraded to a total of 32 drive bays. In such configurations, all drives are connected to one RAID controller. Supported adapters are the ServeRAID M5210, ServeRAID M1215, and N2215 host bus adapter.


Figure 6. Configurations of 2.5-inch drives with one RAID adapter

The following figure shows how models with eight 2.5-inch drive bays can be upgraded to a total of 32 drive bays that use two RAID controller for added performance. Supported adapters are the ServeRAID M5210, ServeRAID M1215, and N2215 host bus adapter.


Figure 7. Configurations of 2.5-inch drives with two RAID adapters

The following figure shows how models with six 3.5-inch hot-swap drive bays can be upgraded to 12 drive bays. Such a configuration requires two RAID controllers. Supported adapters are the ServeRAID M5210, ServeRAID M1215, and N2215 host bus adapter.


Figure 8. Configurations of 3.5-inch drives

For configure-to-order configurations, the server also supports simple-swap 3.5-inch drives. The simple-swap drives can be connected to the 6 Gb SATA ports on the system board of the server or to a RAID controller. Only six 3.5-inch drives are supported; a configuration of 12 simple-swap drives is not supported.


Figure 9. Simple-swap 3.5-inch drives

The server also supports combinations of 2.5-inch drive bays (up to 16) and 3.5-inch drive bays (6 bays). The upgrade path from models with 2.5-inch drives is shown in the following figure. The 3.5-inch drives must be connected to a separate RAID adapter.


Figure 10. Combinations of 2.5-inch and 3.5-inch drive bays from a 2.5-inch base

The following figure shows the upgrade path from models with 3.5-inch drives.


Figure 11. Combinations of 2.5-inch and 3.5-inch drive bays from a 3.5-inch base

Controllers for internal storage

The following table lists the RAID controllers and additional options that are used for internal disk storage of the x3500 M5 server.

Table 10. RAID controllers and HBAs for internal storage

Part
number
Feature
code
Description Maximum
supported
Standard models
where used
12 Gb Controllers
46C9114 A45W ServeRAID M1215 SAS/SATA Controller 2 A2x, B2x, C2x,
C3x, C4x, D2x
46C9110 A3YZ ServeRAID M5210 SAS/SATA Controller 2 G2x, G3x, H2x, J2x
47C8675 A3YY N2215 SAS/SATA HBA 2 -
Hardware upgrades for the M5210
47C8656 A3Z0 ServeRAID M5200 Series 1GB Cache/RAID 5 Upgrade 2 -
47C8660 A3Z1 ServeRAID M5200 Series 1GB Flash/RAID 5 Upgrade 2 G2x, G3x
47C8664 A3Z2 ServeRAID M5200 Series 2GB Flash/RAID 5 Upgrade 2 H2x, J2x
47C8668 A3Z3 ServeRAID M5200 Series 4GB Flash/RAID 5 Upgrade 2 -
Feature on Demand upgrades for the M1215†
00AE930 A5H5 ServeRAID M1200 Zero Cache/RAID 5 Upgrade 1† -
Feature on Demand upgrades for the M5210†
47C8708 A3Z6 ServeRAID M5200 Series Zero Cache/RAID 5 Upgrade 1† -
47C8706 A3Z5 ServeRAID M5200 Series RAID 6 Upgrade 1†* -
47C8710 A3Z7 ServeRAID M5200 Series Performance Accelerator 1†* -
47C8712 A3Z8 ServeRAID M5200 Series SSD Caching Enabler 1†* -

* Requires cache memory upgrade (47C8656, 47C8660, 47C8664 or 47C8668).
† Features on Demand (FoD) upgrades for ServeRAID adapters are applied system-wide; that is, one FoD upgrade is required to activate the feature on all RAID controllers of the same type installed in the server.

The ServeRAID M1215 SAS/SATA Controller has the following specifications:

  • Eight internal 12 Gbps SAS/SATA ports
  • Up to 12 Gbps throughput per port
  • Two internal mini-SAS HD connectors (SFF-8643)
  • Supports connections to SAS/SATA HDDs and SSDs
  • LSI SAS3008 12 Gbps RAID on Chip (ROC) controller
  • Support for RAID levels 0, 1, and 10 standard; support for RAID 5, 50 with optional FoD upgrade
  • Zero Controller Cache, no battery/flash backup
  • Optional support for self-encrypting drives (SEDs) with MegaRAID SafeStore (with RAID 5 upgrade)
  • Fixed stripe size of 64 KB


The ServeRAID M5210 SAS/SATA Controller has the following specifications:

  • Eight internal 12 Gbps SAS/SATA ports
  • Up to 12 Gbps throughput per port
  • Two x4 HD mini-SAS internal connectors (SFF-8643)
  • Supports connections to SAS/SATA HDDs and SSDs and SAS Expanders
  • Supports RAID 0, 1, and 10
  • Supports RAID 5 and 50 with optional M5200 Series RAID 5 upgrades
  • Supports RAID 6 and 60 with the optional M5200 Series RAID 6 upgrade
  • Optional support for self-encrypting drives (SEDs) with MegaRAID SafeStore (with RAID 5 upgrade)
  • Supports 1 GB non-backed cache or 1 GB, 2 GB or 4 GB flash-backed cache
  • PCIe 3.0 x8 host interface
  • Based on the LSI SAS3108 12 Gbps ROC controller


The N2215 SAS/SATA HBA has the following specifications:

  • Eight internal 12 Gbps SAS/SATA ports
  • Up to 12 Gbps throughput per port
  • Two x4 HD mini-SAS internal connectors (SFF-8643)
  • Supports connections to SAS/SATA HDDs and SSDs
  • Optimized for SSD performance
  • No RAID support
  • PCIe 3.0 x8 host interface
  • Based on the LSI SAS3008 12 Gbps controller


For more information, see the list of Lenovo Press Product Guides in the RAID adapters category at this website:
http://lenovopress.com/systemx/raid

Internal drive options

The following table lists hard drive options for internal disk storage of the x3500 M5 server.

Table 11. Drive options for internal disk storage

Part number Feature code Description Maximum supported
3.5-inch hot-swap HDDs - 12 Gbps NL SAS
00FN188 A5VP 2TB 7.2K 12Gbps NL SAS 3.5-inch G2HS 512e HDD 12
00FN208 A5VQ 4TB 7.2K 12Gbps NL SAS 3.5-inch G2HS 512e HDD 12
00FN228 A5VR 6TB 7.2K 12Gbps NL SAS 3.5-inch G2HS 512e HDD 12
3.5-inch hot-swap SEDs - 12 Gbps NL SAS
00FN238 A5VS 2TB 7.2K 12Gbps NL SAS 3.5-inch G2HS 512e SED 12
00FN248 A5VT 4TB 7.2K 12Gbps NL SAS 3.5-inch G2HS 512e SED 12
00FN258 A5VU 6TB 7.2K 12Gbps NL SAS 3.5-inch G2HS 512e SED 12
3.5-inch hot-swap HDDs - 12 Gbps NL SATA
81Y9794 A22T 2TB 7.2K 6Gbps NL SATA 3.5-inch G2HS HDD 12
81Y9798 A22S 3TB 7.2K 6Gbps NL SATA 3.5-inch G2HS HDD 12
49Y6002 A3W9 4TB 7.2K 6Gbps NL SATA 3.5-inch G2HS HDD 12
3.5-inch hot-swap HDDs - 6 Gbps NL SATA
00FN113 A5VD 2TB 7.2K 6Gbps NL SATA 3.5-inch G2HS 512e HDD 12
00FN128 A5VF 3TB 7.2K 6Gbps NL SATA 3.5-inch G2HS 512e HDD 12
00FN143 A5VH 4TB 7.2K 6Gbps NL SATA 3.5-inch G2HS 512e HDD 12
00FN158 A5VK 5TB 7.2K 6Gbps NL SATA 3.5-inch G2HS 512e HDD 12
00FN173 A5VM 6TB 7.2K 6Gbps NL SATA 3.5-inch G2HS 512e HDD 12
3.5-inch simple-swap HDDs - 6 Gbps NL SATA
00FN118 A5VE 2TB 7.2K 6Gbps NL SATA 3.5-inch G2SS 512e HDD 6
00FN133 A5VG 3TB 7.2K 6Gbps NL SATA 3.5-inch G2SS 512e HDD 6
00FN148 A5VJ 4TB 7.2K 6Gbps NL SATA 3.5-inch G2SS 512e HDD 6
00FN163 A5VL 5TB 7.2K 6Gbps NL SATA 3.5-inch G2SS 512e HDD 6
00FN178 A5VN 6TB 7.2K 6Gbps NL SATA 3.5-inch G2SS 512e HDD 6
81Y9810 A22W 2TB 7.2K 6Gbps NL SATA 3.5-inch G2SS HDD 6
81Y9814 A22V 3TB 7.2K 6Gbps NL SATA 3.5-inch G2SS HDD 6
49Y6012 A3WA 4TB 7.2K 6Gbps NL SATA 3.5-inch G2SS HDD 6
2.5-inch hot-swap 15K HDDs - 12 Gbps SAS
00AJ081 A4TR 300GB 15K 6Gbps SAS 2.5-inch G3HS HDD 32
00AJ126 A4TS 600GB 15K 6Gbps SAS 2.5-inch G3HS HDD 32
00NA221 ASBB 300GB 15K 12Gbps SAS 2.5" G3HS 512e HDD 32
00NA231 ASBD 600GB 15K 12Gbps SAS 2.5" G3HS 512e HDD 32
2.5-inch hot-swap 10K HDDs - 12 Gbps SAS
00NA241 ASBF 600GB 10K 12Gbps SAS 2.5" G3HS 512e HDD 32
00NA251 ASBH 900GB 10K 12Gbps SAS 2.5" G3HS 512e HDD 32
00NA261 ASBK 1.2TB 10K 12Gbps SAS 2.5" G3HS 512e HDD 32
00NA271 ASBM 1.8TB 10K 12Gbps SAS 2.5" G3HS 512e HDD 32
2.5-inch hot-swap 15K HDDs - 12 Gbps SAS self-encyrpting drive (SED)
00NA281 ASBP 300GB 15K 12Gbps SAS 2.5" G3HS 512e SED 32
00NA286 ASBQ 600GB 15K 12Gbps SAS 2.5" G3HS 512e SED 32
2.5-inch hot-swap 10K HDDs - 12 Gbps SAS SED
00NA291 ASBR 600GB 10K 12Gbps SAS 2.5" G3HS 512e SED 32
00NA296 ASBS 900GB 10K 12Gbps SAS 2.5" G3HS 512e SED 32
00NA301 ASBT 1.2TB 10K 12Gbps SAS 2.5" G3HS 512e SED 32
00NA306 ASBU 1.8TB 10K 12Gbps SAS 2.5" G3HS 512e SED 32
2.5-inch hot-swap 15K HDDs - 12 Gbps SAS-SSD Hybrid
00NA311 ASBV 300GB 15K 12Gbps SAS 2.5" G3HS 512e Hybrid 32
00NA321 ASBX 600GB 15K 12Gbps SAS 2.5" G3HS 512e Hybrid 32
2.5-inch hot-swap SSDs - 12 Gbps SAS - Enterprise Capacity
00NA671 ASW6 3.84TB 6Gb SAS Enterprise Capacity G3HS MLC SSD 32
2.5-inch hot-swap SSDs - 12 Gbps SAS - Enterprise
00FN379 AS7C 200GB 12G SAS 2.5-inch MLC G3HS Enterprise SSD 32
00FN389 AS7E 400GB 12G SAS 2.5-inch MLC G3HS Enterprise SSD 32
00FN399 AS7G 800GB 12G SAS 2.5-inch MLC G3HS Enterprise SSD 32
00FN409 AS7J 1.6TB 12G SAS 2.5-inch MLC G3HS Enterprise SSD 32
2.5-inch hot-swap SSDs - 12 Gbps SAS SED - Enterprise
00FN419 AS7L 400GB SED 12G SAS 2.5-inch MLC G3HS Enterprise SSD 32
00FN424 AS7M 800GB SED 12G SAS 2.5-inch MLC G3HS Enterprise SSD 32
2.5-inch hot-swap 10K HDDs - 6 Gbps SAS
00AJ096 A4TL 300GB 10K 6Gbps SAS 2.5-inch G3HS HDD 32
00AJ091 A4TM 600GB 10K 6Gbps SAS 2.5-inch G3HS HDD 32
00AJ071 A4TN 900GB 10K 6Gbps SAS 2.5-inch G3HS HDD 32
00AJ146 A4TP 1.2TB 10K 6Gbps SAS 2.5-inch G3HS HDD 32
2.5-inch hot-swap HDDs - 6 Gbps NL SAS
00AJ086 A4TU 1TB 7.2K 6Gbps NL SAS 2.5-inch G3HS HDD 32
00AJ121 A4TT 500GB 7.2K 6Gbps NL SAS 2.5-inch G3HS HDD 32
2.5-inch hot-swap HDDs - 6 Gbps NL SATA
00AJ136 A4TW 500GB 7.2K 6Gbps NL SATA 2.5-inch G3HS HDD 32
00AJ141 A4TX 1TB 7.2K 6Gbps NL SATA 2.5-inch G3HS HDD 32
2.5-inch hot-swap SSDs - 6 Gbps SAS - Enterprise
00AJ217 A4UC 800GB SAS 2.5-inch MLC G3HS Enterprise SSD 32
2.5-inch hot-swap SSDs - 6 Gbps SATA SSDs - Enterprise
00AJ161 A4U4 S3700 400GB SATA 2.5-inch MLC G3HS Enterprise SSD 32
2.5-inch hot-swap SSDs - 6 Gbps SATA - Enterprise Value
00AJ405 A579 480GB SATA 2.5-inch MLC G3HS Enterprise Value SSD 32
2.5-inch hot-swap SSDs - 6 Gbps SATA - Entry
00FN347 AS0J 960GB SATA 2.5-inch MLC G3HS Entry SSD 32

 

Internal backup units

The server supports the internal backup unit options that are listed in the following table.

Table 12. Internal tape drives

Part
number
Feature
code
Description Maximum
supported
Drives
- A2U7 RDX 3 Internal USB Drive 1
00D2786 A2VE RDX Internal USB 3.0 Dock with 320 GB Cartridge (includes USB cable) 1
00D2787 A2VF RDX Internal USB 3.0 Dock with 500 GB Cartridge (includes USB cable) 1
00D2788 A2VG RDX Internal USB 3.0 Dock with 1 TB Cartridge (includes USB cable) 1
49Y9898 5345 Half High LTO Gen 5 Internal SAS Tape Drive* 2
00D8924 A3S3 Half High LTO Ultrium Gen 6 Internal SAS Tape Drive* 2
Media
46W6589 A3S6 LTO Ultrium Gen 6 Single Media (2.6 TB native capacity)
46C5367 5708 RDX 320GB Cartridge
46C5368 5709 RDX 500GB Cartridge
81Y3647 A1VL RDX 1TB Cartridge

* Supported with the N2215 SAS/SATA HBA; also requires 12Gb SAS Cable for LTO Tape drive, SBB 00MV226, feature code ASTU

USB devices are attached to the internal USB connector. For option part number orders, the USB cable is included with the RDX drive. For CTO, use feature code 9266.

For more information, see the list of Product Guide, RDX USB 3.0 Disk Backup Solution, which is available at this website:
http://lenovopress.com/tips0894

Optical drives

The server supports the optical drive options that are listed in the following table.

Table 13. Optical drives

Part number Feature
code
Description Maximum
supported
Standard models
where used
None* 4154 Half-High SATA DVD-ROM 2 All standard models
81Y6404 4155 Half-High SATA Multiburner 2 -

* This option is available via CTO only or is already installed in standard models.

The two half-high drives in the table can be installed in any open 5.25-inch drive bay.

The Half-High SATA DVD-ROM drive supports the following media and speeds for reading:

  • CD-ROM 48X
  • CD-DA (DAE) 40X
  • CD-R 48X
  • CD-RW 40X
  • DVD-ROM (single layer) 16X
  • DVD-ROM (dual layer) 12X
  • DVD-R (4.7 GB) 16X
  • DVD-R DL 12X
  • DVD+R 16X
  • DVD+R DL 12X
  • DVD-RW (4.7 GB) 12X
  • DVD+RW 12X
  • DVD-RAM (4.7/9.4 GB) 6X

The Half-High SATA multiburner drive supports the same media and speeds for reading as HH DVD-ROM. In addition, this drive supports the following media and speeds for writing:

  • CD-R 24X
  • CD-RW 4X
  • High Speed CD-RW 10X
  • Ultra Speed CD-RW 16X
  • DVD-R 8X
  • DVD-R DL 8X
  • DVD+R 8X
  • DVD+R DL 8X
  • DVD-RW 6X
  • DVD+RW 8X
  • DVD-RAM 3X

 

I/O expansion options

The server supports up to seven PCIe 3.0 slots: Four slots (1 - 4) when one CPU is installed or seven slots when two CPUs are installed. The following slot form factors are available:

  • Slot 1: PCIe 3.0 x8 (x8 wired); full-height, half-length
  • Slot 2: PCIe 3.0 x16 (x8 wired); full-height, full-length
  • Slot 3: PCIe 3.0 x16 (x16 wired); full-height, full-length
  • Slot 4: PCIe 3.0 x8 (x8 wired); full-height, full-length
  • Slot 5: PCIe 3.0 x8 (x8 wired); full-height, half-length (requires second processor)
  • Slot 6: PCIe 3.0 x16 (x16 wired); full-height, full-length (requires second processor)
  • Slot 7: PCIe 3.0 x16 (x16 wired) full-height, full-length (requires second processor)


Slots 3 and 6 support double-wide GPUs

The COM Port Bracket, part number 00KC332, is used for making an external serial port available at the rear of the server. This option includes the bracket and the cable. The COM Port option is mounted in one of the PCIe slots and that PCIe slot cannot be used. The following table lists the PCIe slot options.

Table 14. System x3500 M5 COM Port Kit ordering information

Part number Feature
code
Description Maximum
supported
00KC332 ARZ0 System x3500 M5 COM Port Kit 1

 

Network adapters

The x3550 M5 supports four integrated Gigabit Ethernet ports with the following features:

  • A Broadcom BCM5719 chip
  • Four Gigabit Ethernet ports
  • NIC Teaming (load balancing and failover)
  • Ethernet features:
    • Compliant with 1 Gb Ethernet IEEE 802.3, 802.3u, and 802.3ab PHY specifications
    • Integrated PHY for 10/100/1000 Mbps for multispeed, full, and half-duplex auto-negotiation
    • Automatic MDI crossover
    • IEEE 802.3x-compliant flow control support
    • IEEE 1588 protocol and 802.1AS time synchronization implementation
    • IEEE802.3az - Energy Efficient Ethernet (EEE)
  • I/O Virtualization features:
    • I/O Virtualization support for VMware NetQueue and Microsoft virtual machine queue (VMQ)
    • Function Level Reset (FLR)
    • IEEE 802.1q Virtual Local Area Network (VLAN) tagging support
  • Stateless offload and performance features:
    • TCP, IP, and User Datagram Protocol (UDP) checksum offload
    • TCP segmentation offload (TCO)
    • Large Send Offload (LSO)
    • Receive Side Scaling (RSS) and Transmit Side Scaling (TSS)
    • Message Signal Interrupt (MSI) and Message Signal Interrupt Extension (MSI-X) support
    • Support for jumbo frames up to 9600 bytes


The following table lists other supported network adapters.

Table 15. Network adapters

Part number Feature
code
Description Maximum
supported
(1 CPU / 2 CPUs)
40 Gb Ethernet
00D9550 A3PN Mellanox ConnectX-3 40GbE / FDR IB VPI Adapter* 4 / 7
10 Gb Ethernet
44T1370 A5GZ Broadcom NetXtreme 2x10GbE BaseT Adapter 4 / 7
94Y5180 A4Z6 Broadcom NetXtreme Dual Port 10GbE SFP+ Adapter* 4 / 7
00JY830 A5UU Emulex VFA5 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW* 4 / 7
None AS3M Emulex VFA5 2x10 GbE SFP+ Integrated Adapter* 1 / 1
00JY820 A5UT Emulex VFA5 2x10 GbE SFP+ PCIe Adapter* 4 / 7
00JY824 A5UV Emulex VFA5 FCoE/iSCSI SW for PCIe Adapter for System x (FoD)
(Features on Demand upgrade for 00JY820 and feature code AS3M)
4 / 7
49Y7960 A2EC Intel X520 Dual Port 10GbE SFP+ Adapter* 4 / 7
49Y7970 A2ED Intel X540-T2 Dual Port 10GBaseT Adapter 4 / 7
81Y3520 AS73 Intel X710 2x10GbE SFP+ Adapter* 4 / 7
00D9690 A3PM Mellanox ConnectX-3 10 GbE Adapter* 4 / 7
90Y4600 A3MR QLogic 8200 Dual Port 10GbE SFP+ VFA* 4 / 7
00Y5624 A3MT QLogic 8200 VFA FCoE/iSCSI License for System x (FoD)
(Features on Demand upgrade for 90Y4600)
4 / 7
47C9977 A522 Solarflare SFN7122F 2x10GbE SFP+ Flareon Ultra* 4 / 7
1 Gb Ethernet
42C1780 2995 Broadcom NetXtreme 2xGbE BaseT Adapter 4 / 7
90Y9370 A2V4 Broadcom NetXtreme I Dual Port GbE Adapter 4 / 7
90Y9352 A2V3 Broadcom NetXtreme I Quad Port GbE Adapter 4 / 7
49Y4230 5767 Intel Ethernet Dual Port Server Adapter I340-T2 4 / 7
49Y4240 5768 Intel Ethernet Quad Port Server Adapter I340-T4 4 / 7
00AG510 A56L Intel I350-T2 2xGbE BaseT Adapter 4 / 7
00AG520 A56M Intel I350-T4 4xGbE BaseT Adapter 4 / 7

* Require SFP+ optical transceivers or DAC cables that must be purchased separately.

For more information, see the list of Lenovo Press Product Guides in the Networking adapters category at:
http://lenovopress.com/systemx/networkadapters

Storage host bus adapters

The following table lists storage HBAs that are supported by the x3500 M5 server.

Table 16. Storage adapters

Part number Feature
code
Description Maximum
supported
(1 CPU / 2 CPUs)
16 Gb Fibre Channel
81Y1668 A2XU Brocade 16Gb FC Single-port HBA for System x 4 / 7
81Y1662 A2W6 Emulex 16Gb FC Dual-port HBA for System x 4 / 7
81Y1655 A2W5 Emulex 16Gb FC Single-port HBA for System x 4 / 7
00Y3341 A3KX QLogic 16Gb FC Dual-port HBA for System x 4 / 7
00Y3337 A3KW QLogic 16Gb FC Single-port HBA for System x 4 / 7
8 Gb Fibre Channel
46M6050 3591 Brocade 8Gb FC Dual-port HBA for System x 4 / 7
46M6049 3589 Brocade 8Gb FC Single-port HBA for System x 4 / 7
42D0494 3581 Emulex 8Gb FC Dual-port HBA for System x 4 / 7
42D0485 3580 Emulex 8Gb FC Single-port HBA for System x 4 / 7
42D0510 3579 QLogic 8Gb FC Dual-port HBA for System x 4 / 7
42D0501 3578 QLogic 8Gb FC Single-port HBA for System x 4 / 7
SAS
46M0907 5982 6 Gb SAS HBA Controller 4 / 7
00AE912 A5M0 N2225 SAS/SATA HBA for System x 4 / 7
00AE916 A5M1 N2226 SAS/SATA HBA for System x 4 / 7


For more information, see the list of Lenovo Press Product Guides in the Host bus adapters category at this website:
http://lenovopress.com/systemx/hba

PCIe SSD adapters

The server currently does not support High IOPS SSD adapters.

GPU adapters

The x3500 M5 server supports graphics processing units (GPUs) that are listed in the following table. Up to two GPUs are supported, depending on the number of processors that are installed in a server.

Table 17. GPU adapters

Part number Feature code Description Maximum supported
(1 CPU / 2 CPUs)
00FP672 A3YV NVIDIA Quadro K6000 1 / 2

The following other rules apply:

  • If two GPUs are installed, they must be identical
  • The first GPU is installed in slot 3; the second GPU is installed in slot 6 and requires the second processor to be installed.
  • The number of GPUs that can be installed depends on the type of power supply that is installed and the type and number of other components that are installed. For more information,see the Power Supply section.
  • If a NVIDIA card is installed, the maximum memory that can be installed is 1 TB.

 

Power supplies and redundant cooling

The server supports up to two redundant power supplies. Standard models come with one or two power supplies (depending on the model).

The server also comes standard with two (for models with one processor installed) or four (for models with two processors installed) hot-swap cooling fans. For models with only one processor, an optional Redundant Cooling Kit provides N+1 cooling redundancy. The following table lists the power supplies and redundant cooling upgrade options.

Table 18. Power supplies

Part number Feature code Description Maximum
supported
Standard models
where used
00AL533 A5MY System x 550W High Effiency Platinum AC Power Supply 2 A2x, B2x, C2x, C3x, C4x, D2x
00AL534 A5MZ System x 750W High Efficiency Platinum AC Power Supply 2 G2x, G3x
00AL536 A5N0 System x 900W High Efficency Platinum AC Power Supply 2 H2x, J2x
00AL535 A5N1 System x 750W High Efficiency Titanium AC Power Supply 2 -
None* A5CH System x 550W High Efficency Platinum AC Fixed Power Supply 1 -
00AL537 A5D6 System x3500 M5 Redundant Cooling Kit 1 -

* CTO only
The following table shows the combinations supported.

Table 19. Supported configurations

Power supply 550 W (A) 550 W (B) 750 W (A) 750 W (B) 900 W (1A) 900 W (2A) 900 W (2B) 900 W (2C) 900 W (2D) 900 W (2E)
Maximum processors 1 2, max 90W 1 2 1 2 2 2 2, max 135W 2, max 90W
Memory maximums (mutually exclusive)
    RDIMMs
No limit No limit No limit No limit No limit No limit No limit No limit No limit 12
    LRDIMMs
0 0 0 0 0 12 0 No limit 0 0
Drive maximums (mutually exclusive)
    3.5-inch drives only
No limit 6 No limit No limit No limit No limit 6 6 No limit 6
    2.5-inch drives only
16 8 16 16 No limit 24 8 8 No limit 8
    Intermix 3.5-in and 2.5-in drives
6x 3.5 + 8x 2.5 No 6x 3.5 + 8x 2.5 6x 3.5 + 8x 2.5 No limit No limit 0 0 No limit 0
PCIe adapters (non-GPU)* No limit No limit No limit No limit No limit No limit No limit No limit No limit 2
Maximum GPUs 0 0 1 0 1 0 1 0 0 2

* GPUs use two PCIe slots; therefore, if a GPU is installed, the number of non-GPU adapters that are installed is reduced by two.

AC power supply options ships without a line cord, it must be purchased separately. Country-specific line cords and rack cables can be ordered if needed, as listed in the following table.

Table 20. Power cables

Part number Feature code Description
Rack power cables
39Y7932 6263 4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
39Y7937 6201 1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
39Y7938 6204 IEC309 C20 to C13 rack jumper cable
Country-specific power cords
39Y7917 6212 European 10A line C13 to CEE 7/7 (2.8M)
39Y7918 6213 Denmark 10A line C13 to DK2-5A (2.8M)
39Y7919 6216 Switzerland 10A line C13 to SEV 1011 (2.8M)
39Y7920 6218 Israel 10A line C13 to SI 32 (2.8M)
39Y7921 6217 Italy 10A line C13 to CEE 7/7 (2.8M)
39Y7922 6214 South Africa 10A line C13 to SABS 164/1 (2.8M)
39Y7923 6215 United Kingdom 10A line C13 to BS 1363 (2.8M)
39Y7924 6211 Australia/NZ 10A line C13 to SAA-AS C112 (2.8M)
39Y7925 6219 Korea 7A line C13 to KETI 15A/250V (2.8M)
39Y7927 6269 India 6A line C13 to Fig 68 (2.8M)
39Y7928 6210 China 6A line C13 to GB 2099.1 (2.8M)
39Y7929 6223 Brazil 10A line C13 to NBR 6147 (2.8M)
39Y7930 6222 Argentina 10A line C13 to IRAM 2063 (2.8M)
39Y7931 6207 Power Cable - C13 / NEMA 5-15P 14ft
00CG265 A53E Power Cord Taiwan AC plug 10A/250V, 2.8M; OPT
00CG267 A53F Power Cord Taiwan AC plug 15A/125V; 2.8M; OPT
46M2592 A1RF 10A/250V C13 to NEMA 6-15P 2.8m line cord
46M2593 A1RE Japan 10A/100V C13 to JIS C-8303 2.8m line cord

 

Integrated virtualization

The server supports the VMware vSphere (ESXi) hypervisor on one or two SD cards with the optional SD Media Adapter for System x. This adapter is in a dedicated connector on the system board, as shown in the following figure.


Figure 12. SD Media Adapter with one SD Card installed

When only one SD card is installed in the adapter, you can create up to 16 volumes, each of which is presented to UEFI as a bootable device. When two SD Media cards are inserted, volumes can be mirrored (RAID 1) across both cards, up to a total of eight mirrored volumes. The use of mirrored volumes improves system availability because the server remains operational, even if one SD card fails. The RAID functionality is handled internally by the SD Media Adapter.

The following table shows the available options. The table also indicates whether the option includes the SD Media RAID Adapter and how many SD cards are included.

Table 21. Virtualization options

Part number Feature
code
Description Includes
Adapter
SD Cards
Included
00ML706 A5TJ SD Media Adapter for Systems x
(Option 00ML706 includes 2 blank 32GB SD cards)
Yes 2*
00ML700 AS2V Blank 32GB SD Media for System x No 2
None** AS4B RAID Adapter for SD Media w/ VMware ESXi 5.1 U2 (2 SD Media, RAIDed) Yes 2
None** ASCG RAID Adapter for SD Media w/ VMware ESXi 5.1 U2 (1 SD Media) Yes 1

* Option 00ML706 includes two 32GB SD cards; however, for CTO orders, feature code A5TJ does not include SD media and the 32GB cards and VMware vSphere preload must be selected separately.
** CTO only.

Systems management

The server contains IMM2.1, which provides advanced service-processor control, monitoring, and an alerting function. If an environmental condition exceeds a threshold or if a system component fails, the IMM2.1 lights LEDs to help you diagnose the problem, records the error in the event log, and alerts you to the problem. Optionally, the IMM2.1 also provides a virtual presence capability for remote server management capabilities.

The IMM provides remote server management through the following industry-standard interfaces:

  • Intelligent Platform Management Interface (IPMI) Version 2.0
  • Simple Network Management Protocol (SNMP) Version 3
  • Common Information Model (CIM)
  • Web browser


The optional Integrated Management Module Advanced Upgrade is required for enabling remote presence and blue-screen capture features. The remote presence feature provides the following functions:

  • Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel colors, regardless of the system state
  • Remotely accessing the server by using the keyboard and mouse from a remote client
  • Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote client, and mapping ISO and diskette image files as virtual drives that are available for use by the server
  • Uploading a diskette image to the IMM memory and mapping it to the server as a virtual drive


The blue-screen capture feature captures the video display contents before the IMM restarts the server when the IMM detects an operating-system hang condition. A system administrator can use the blue-screen capture to assist in determining the cause of the hang condition. The following table lists the remote management option.

Table 22. Remote management option

Part number Feature code Description Maximum
supported
90Y3901 A1ML Integrated Management Module Advanced Upgrade 1


All standard models include basic light path diagnostics, which include system LEDs on the front of the server (see the following figure) and LEDs near the monitored components (for example, the DIMM error LED on the system board). The server also offers an optional upgrade to supply another array of light path diagnostic LEDs on the front of the chassis.

The following table lists the ordering information for the light path diagnostics panel upgrade kit.

Table 23. Remote management option

Part number Feature code Description Maximum
supported
00AL566 A5N3 System x3500 M5 Lightpath Upgrade Kit 1


The following figure shows the meaning of each LED.


Figure 13. System LEDs and the optional light path diagnostics panel

Note: The light path diagnostics panel upgrade kit supplies the array of LEDs that is mounted in a bracket that is installed inside the server, as shown in the following figure. The light path diagnostics indicators are still visible on the front of the server, even if the upgrade kit is not installed.


Figure 14. System x3500 M5 Lightpath Upgrade Kit

IBM Security Key Lifecycle Manager for System x SEDs - FoD (SKLM - FoD) is an optional feature, which is available in System x environments that centralizes, simplifies, and automates the data encryption key management process to help minimize risk and reduce operational costs. SKLM - FoD offers a simple and robust solution for key storage, key serving, and key lifecycle management for self-encrypting drives (SEDs) in local and distributed System x environments. The FoD upgrade can be configured with the ServeRAID M5210 and M1215 RAID controllers paired with SEDs. The following table lists SKLM-FoD part numbers.

Table 24. Security Key Lifecycle Manager - FoD part numbers

Part number Feature code Description Maximum supported
United States, Canada, Asia Pacific and Japan
00D9998 A5U1 IBM SKLM for System x w/SEDs - FoD per Install w/1Yr S&S 1
00D9999 AS6C IBM SKLM for System x w/SEDs - FoD per Install w/3Yr S&S 1
Latin America, Europe, Middle East and Africa
00FP648 A5U1 IBM SKLM for System x w/SEDs - FoD per Install w/1Yr S&S 1
00FP649 AS6C IBM SKLM for System x w/SEDs - FoD per Install w/3Yr S&S 1

 

Supported operating systems

The server supports the following operating systems:

  • Microsoft Windows Server 2012 R2
  • Microsoft Windows Server 2008 R2
  • Microsoft Windows Server 2012
  • SUSE LINUX Enterprise Server 11 for AMD64/EM64T
  • SUSE LINUX Enterprise Server 11 with Xen for AMD64/EM64T
  • Red Hat Enterprise Linux 6 Server x64 Edition
  • Red Hat Enterprise Linux 7
  • SUSE Enterprise Linux Server (SLES) 12
  • SUSE Linux Enterprise Server 12 with XEN
  • VMware vSphere 5.5 (ESXi)
  • VMware vSphere 5.1 (ESXi)


Some operating systems might have support delayed until 60 or 90 days after general availability. For more information about the supported specific versions and service levels and any other prerequisites. see the following ServerProven® website :
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml

Physical and electrical specifications

The server features the following dimensions and weight (approximate):

  • Tower:
    • Width: 218 mm (8.6 in)
    • Depth: 720 mm (28.3 in)
    • Height: 440 mm (17.25 in)
    • Weight fully configured: 45.5 kg (100.3 lb)
    • Weight minimum configuration: 30.8 kg (67.9 lb)
  • With rack conversion kit:
    • Width: 423 mm (16.6 in)
    • Depth: 706 mm (27.8 in)
    • Height: 218 mm (8.6 in )
    • Weight fully configured: 44.2 kg (97.4 lb)
    • Weight minimum configuration: 29.5 kg (65 lb) minimum configuration


The server features the following supported environment:

  • Design to ASHRAE Class A3, ambient of 36 °C to 40 °C (96.8 °F to 104 °F), with relaxed support:
    • Supports cloud-like workload with no performance degradation acceptable (Turbo-Off).
    • Under no circumstance can any combination of worst-case workload and configuration result in system shutdown or design exposure at 40 °C.
    • The worst-case workload (like Linpack, Turbo-On) might have performance degradation.
  • Air temperature:
    • Server on: 5 - 40 °C (41 to 104 °F); altitude: 0 - 950 m (3,100 ft)
    • Server on: 5 - 28 °C (41 - 82 °F); altitude: 915 m (3,000 ft) - 3050 m (10,000 ft)
    • Server off (with standby power): 5 - 45 °C (41 - 113 °F)
    • Storage: 1 - 60 °C (34 - 140 °F)
    • Shipping: -40 - 60 °C (-40 - 140 °F)
  • Humidity: 8 - 85%, Max. Dew Point 24 °C
  • Electrical:
    • Models with 900 W AC power supplies:
      • 100 - 127 (nominal) V ac; 50 Hz or 60 Hz; 10.3 A
      • 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 5.0 A
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.15 kVA
        • Maximum configuration: 1.194 kVA
    • Models with 750 W Platinum AC power supplies:
      • 100 - 127 (nominal) V ac; 50 Hz or 60 Hz; 8.6 A
      • 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 4.2 A
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.15 kVA
        • Maximum configuration: 1.015 kVA
    • Models with 750 W Titanium AC power supplies:
      • 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 4.2 A
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.15 kVA
        • Maximum configuration: 0.965 kVA
    • Models with 550 W AC power supplies:
      • 100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 6.5 A
      • 200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 3.3 A
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.16 kVA
        • Maximum configuration: 0.732 kVA
  • BTU output:
      • Base configuration: 2931 Btu/hr (859 watts)
      • Maximum configuration: 4043 Btu/hr (1185 watts)
  • Acoustical noise emissions:
    • Sound power, idling: 6.0 bels
    • Sound power, operating: 6.0 bels

 

Warranty options

The Lenovo System x3500 M5 has a three-year warranty with 24x7 standard call center support and 9x5 Next Business Day onsite coverage. Also available are Lenovo Services warranty maintenance upgrades and post-warranty maintenance agreements, with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.

Lenovo warranty service upgrade offerings are country-specific. Not all warranty service upgrades are available in every country. For more information about Lenovo warranty service upgrade offerings that are available in your country, visit the Lenovo Services website:

https://www-304.ibm.com/sales/gss/download/spst/servicepac/extProductSelectorWWW.do

The following table explains warranty service definitions in more detail.

Table 25. Warranty service definitions

Term Description
On-site service A service technician will arrive at the client’s location for equipment service.
24x7x2 hour A service technician is scheduled to arrive at the client’s location within two hours after remote problem determination is completed. Lenovo provides service around the clock, every day, including Lenovo holidays.
24x7x4 hour A service technician is scheduled to arrive at the client’s location within four hours after remote problem determination is completed. Lenovo provides service around the clock, every day, including Lenovo holidays.
9x5x4 hour A service technician is scheduled to arrive at the client’s location within four business hours after remote problem determination is completed. Lenovo provides service 8:00 am - 5:00 pm in the client's local time zone, Monday-Friday, excluding Lenovo holidays. For example, if a customer reports an incident at 3:00 pm on Friday, the technician will arrive by 10:00 am the following Monday.
9x5 next business day A service technician is scheduled to arrive at the client’s location on the business day after remote problem determination is completed. Lenovo provides service 8:00 am - 5:00 pm in the client's local time zone, Monday - Friday, excluding Lenovo holidays. Calls received after 4:00 pm local time require an extra business day for service dispatch. Next business day service is not guaranteed.
Committed Repair Problems receive priority handling so that repairs are completed within the committed time of 6, 8, or 24 hours. Lenovo provides service 24 hours/day, every day, including Lenovo holidays.


The following Lenovo warranty service upgrades are available:

  • Warranty and maintenance service upgrades:
    • Three, four, or five years of 9x5 or 24x7 service coverage
    • Onsite response from next business day to 2 or 4 hours
    • Committed repair service
    • Warranty extension of up to 5 years
    • Post warranty extensions
  • Committed Repair Service

    Committed Repair Services enhances the level of Warranty Service Upgrade or Post Warranty/Maintenance Service offering associated with the selected systems. Offerings vary and are available in select countries.

    • Priority handling to meet defined time frames to restore the failing machine to good working condition
    • Committed repair service levels are measured within the following coverage hours:
      • 24x7x6: Service performed 24 hours per day, 7 days per week, within 6 hours
      • 24x7x8: Service performed 24 hours per day, 7 days per week, within 8 hours
      • 24x7x24: Service performed 24 hours per day, 7 days per week, within 24 hours
  • Hard Drive Retention

    Lenovo’s Hard Drive Retention service is a multi-drive hard drive retention offering that ensures your data is always under your control, regardless of the number of hard drives that are installed in your Lenovo server. In the unlikely event of a hard drive failure, you retain possession of your hard drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The Hard Drive Retention service can be purchased in convenient bundles with our warranty upgrades and extensions.

  • Microcode Support

    Keeping microcode current helps prevent hardware failures and security exposure. There are two levels of service: analysis of the installed base and analysis and update where required. Offerings vary by country and can be bundled with other warranty upgrades and extensions.

  • Remote Technical Support Services (RTS)

    RTS provides comprehensive technical call center support for covered servers, storage, operating systems, and applications. Providing a single source for support of hardware and software issues, RTS can reduce problem resolution time, decreasing the cost to address technical problems and increasing uptime. Offerings are available for Windows, Linux, IBM Systems Director, VMware, Microsoft business applications, and Lenovo System x storage devices, and IBM OEM storage devices.

 

Regulatory compliance

The server conforms to the following standards:

  • FCC - Verified to comply with Part 15 of the FCC Rules, Class A
  • Canada ICES-003, issue 5, Class A
  • UL/IEC 60950-1
  • CSA C22.2 No. 60950-1-07
  • NOM-019
  • Argentina IEC60950-1
  • Japan VCCI, Class A
  • IEC-60950-1 (CB Certificate and CB Test Report)
  • Australia/New Zealand AS/NZS CISPR 22:2006, Class A; AS/NZS 60950.1
  • Taiwan BSMI CNS13438, Class A ;CNS14336-1
  • GB9254 Class A, GB17625.1
  • China CCC GB4943.1
  • Korea KN22, Class A; KN24

 

External disk storage expansion

The server supports attachment to external storage expansion enclosures, such as the EXP2500 series, by using the ServeRAID M5225 SAS/SATA Controller. The server can also be attached to supported external storage systems by using a supported HBA. For more information, see the following table.

Table 26. RAID controllers and options for external disk storage expansion

Part number Feature code Description Maximum supported Standard models where used
12 Gb RAID controllers
00AE938 A5ND ServeRAID M5225-2GB SAS/SATA Controller 4 -
Feature on Demand (FoD) upgrades for the M5225
47C8706 A3Z5 ServeRAID M5200 Series RAID 6 Upgrade 1* -
47C8710 A3Z7 ServeRAID M5200 Series Performance Accelerator 1* -
47C8712 A3Z8 ServeRAID M5200 Series SSD Caching Enabler 1* -

* One FoD upgrade for the M5225 activates the feature on all M5225 controllers that are installed in a server.

The ServeRAID M5225 SAS/SATA Controller has the following specifications:

  • Eight external 12 Gbps SAS/SATA ports
  • Supports 12, 6, and 3 Gb/s SAS and 6 and 3 Gb/s SATA data transfer rates
  • Two external x4 mini-SAS HD connectors (SFF-8644)
  • Supports 2 GB flash-backed cache (standard)
  • Supports RAID levels 0, 1, 5, 10, and 50 (standard)
  • Supports RAID 6 and 60 with the optional M5200 Series RAID 6 Upgrade
  • Supports optional M5200 Series Performance Accelerator and SSD Caching upgrades
  • PCIe x8 Gen 3 host interface
  • Based on the LSI SAS3108 12 Gbps ROC controller
  • Supports connectivity to the EXP2512 and EXP2524 storage expansion enclosures


For more information about the ServeRAID M5225, see the Lenovo Press Product Guide at http://lenovopress.com/tips1258

The ServeRAID M5225 SAS/SATA Controller supports connectivity to external expansion enclosures that are listed in the following table. Up to nine expansion enclosures can be daisy-chained per one M5225 external port. For better performance, distribute expansion enclosures evenly across both M5225 ports.

Table 27. External expansion enclosures

Part number Description Maximum quantity supported per one M5225
70F0 / 70F1 Lenovo ThinkServer SA120 8
610012X EXP2512 Storage Enclosure 17
610024X EXP2524 Storage Enclosure 9


Lenovo ThinkServer SA120 support

For details about supported drives and cables for the Lenovo ThinkServer SA120, see the Lenovo Press Product Guide:
http://lenovopress.com/tips1234

EXP2512 and EXP2524 support

The external SAS cables that are listed in the following table support connectivity between external expansion enclosures and the ServeRAID M5225 SAS/SATA Controller.

Table 28. External SAS cables for external storage expansion enclosures

Part number Description Maximum quantity supported per one enclosure
Server to Expansion enclosure connectivity (Mini-SAS HD x4 to Mini-SAS x4)
00MJ162 0.6m SAS Cable (mSAS HD to mSAS) 1
00MJ163 1.5m SAS Cable (mSAS HD to mSAS) 1
00MJ166 3m SAS Cable (mSAS HD to mSAS) 1
Expansion enclosure to Expansion enclosure connectivity (Mini-SAS x4 to Mini-SAS x4)
39R6529 1 m SAS Cable 1
39R6531 3 m SAS Cable 1


The following table lists drives that are supported by EXP2512 external expansion enclosures.

Table 29. Drive options for EXP2512 external expansion enclosures

Part number Description Maximum quantity supported per one enclosure
3.5-inch NL SAS HS HDDs
00NC555 2TB 7,200 rpm 6Gb SAS NL 3.5-inch HDD 12
00NC557 3TB 7,200 rpm 6Gb SAS NL 3.5-inch HDD 12
00NC559 4TB 7,200 rpm 6Gb SAS NL 3.5-inch HDD 12


The following table lists HDDs that are supported by EXP2524 external expansion enclosures.

Table 30. Drive options for EXP2524 external expansion enclosures

Part number Description Maximum quantity supported per one enclosure
2.5-inch NL SAS HS HDDs
00NC571 1TB 7,200 rpm 6Gb SAS NL 2.5-inch HDD 24
2.5-inch SAS HS HDDs
00NC561 146GB 15,000 rpm 6Gb SAS 2.5-inch HDD 24
00NC563 300GB 15,000 rpm 6Gb SAS 2.5-inch HDD 24
00NC565 600GB 10,000 rpm 6Gb SAS 2.5-inch HDD 24
00NC567 900GB 10,000 rpm 6Gb SAS 2.5-inch HDD 24
00NC569 1.2TB 10,000 rpm 6Gb SAS 2.5-inch HDD 24
2.5-inch SAS HS SSDs
00NC573 200GB 6Gb SAS 2.5-inch SSD 24
00NC575 400GB 6Gb SAS 2.5-inch SSD 24

 

External disk storage systems

The following table lists the external storage systems that are supported by the server and can be ordered through the System x sales channel.

Table 31. External disk storage systems

Part number Description
2071CU2 IBM Storwize V3500 LFF Dual Control Enclosure
2071CU3 IBM Storwize V3500 SFF Dual Control Enclosure
6099L2C IBM Storwize V3700 3.5-inch Storage Controller Unit
6099S2C IBM Storwize V3700 2.5-inch Storage Controller Unit
6099T2C IBM Storwize V3700 2.5-inch DC Storage Controller Unit
6194L2C IBM Storwize V5000 LFF Control Enclosure
6194LEU IBM Storwize V5000 LFF Expansion Enclosure
6194S2C IBM Storwize V5000 SFF Control Enclosure
6194SEU IBM Storwize V5000 SFF Expansion Enclosure
6195SC5 IBM Storwize V7000 2.5-inch Storage Controller Unit
 6195LEF IBM Storwize V7000 3.5-inch Storage Expansion Unit
 6195SEF IBM Storwize V7000 2.5-inch Storage Expansion Unit


For more information, see the list of Product Guides in the System Storage category at this website:
http://lenovopress.com/systemx/externalstorage

External backup units

The server supports the external backup attachment options that are listed in the following table.

Table 32. External backup options

Part number Description
External tape expansion enclosures for internal tape drives
87651UX 1U Tape Drive Enclosure
87651NX 1U Tape Drive Enclosure (with Nema 5-15P LineCord)
Tape enclosure adapters (with cables)
44E8869 USB Enclosure Adapter Kit
40K2599 SAS Enclosure Adapter Kit
Internal backup drives supported by external tape enclosures
00D2786 RDX Internal USB 3.0 Dock with 320GB Cartridge
00D2787 RDX Internal USB 3.0 Dock with 500GB Cartridge
00D2788 RDX Internal USB 3.0 Dock with 1TB Cartridge
49Y9898 Half High LTO Gen 5 Internal SAS Tape Drive
00D8924 Half High LTO Ultrium Gen 6 Internal SAS Tape Drive
External backup units*
362532Y RDX External USB 3.0 Dock with 320GB Cartridge
362550Y RDX External USB 3.0 Dock with 500GB Cartridge
36251TY RDX External USB 3.0 Dock with 1TB Cartridge
3628L5X Half High LTO Gen 5 External SAS Tape Drive (with US line cord)
3628N5X Half High LTO Gen 5 External SAS Tape Drive (without line cord)

* These external tape drives can be ordered through the System x sales channel. The server might support other tape drives that are not listed in this table. For more information, see the IBM System Storage Interoperation Center (SSIC) at this website:
http://www.ibm.com/systems/support/storage/ssic

For more information, see the list of Lenovo Press Product Guides in the Backup units category at this website:
http://lenovopress.com/systemx/tape

Top-of-rack Ethernet switches

The server supports the top-of-rack Ethernet switches that are listed in the following table.

Table 33. Top-of-rack switches

Part number Description
1 Gb top-of-rack switches
7159BAX Lenovo RackSwitch G7028 (Rear to Front)
7159CAX Lenovo RackSwitch G7052 (Rear to Front)
715952F Lenovo RackSwitch G8052 (Front to Rear)
7159G52 Lenovo RackSwitch G8052 (Rear to Front)
10 Gb top-of-rack switches
7159BF7 Lenovo RackSwitch G8124E (Front to Rear)
7159BR6 Lenovo RackSwitch G8124E (Rear to Front)
715964F Lenovo RackSwitch G8264 (Front to Rear)
7159G64 Lenovo RackSwitch G8264 (Rear to Front)
7159DFX Lenovo RackSwitch G8264CS (Front to Rear)
7159DRX Lenovo RackSwitch G8264CS (Rear to Front)
7159CFV Lenovo RackSwitch G8272 (Front to Rear)
7159CRW Lenovo RackSwitch G8272 (Rear to Front)
7159GR5 Lenovo RackSwitch G8296 (Front to Rear)
7159GR6 Lenovo RackSwitch G8296 (Rear to Front)
40 Gb top-of-rack switches
7159BFX Lenovo RackSwitch G8332 (Front to Rear)
7159BRX Lenovo RackSwitch G8332 (Rear to Front)

 
For more information, see the list of Lenovo Press Product Guides in the Top-of-rack switches category at this website:
http://lenovopress.com/systemx/tor

Uninterruptible power supply units

The server supports attachments to the uninterruptible power supply (UPS) units that are listed in the following table.

Table 34. Uninterruptible power supply units

Part number Description
Tower UPS units
55951AX T1kVA Tower UPS (100-125VAC)
55951KX T1kVA Tower UPS (200-240VAC)
55952AX T1.5kVA Tower UPS (100-125VAC)
55952KX T1.5kVA Tower UPS (200-240VAC)
53961AX 1000VA LCD Tower UPS (120V)
53961JX 1000VA LCD Tower UPS (100V)
53961KX 1000VA LCD Tower UPS (230V)
53962AX 1500VA LCD Tower UPS (120V)
53962JX 1500VA LCD Tower UPS (100V)
53962KX 1500VA LCD Tower UPS (230V)
Rack-mounted or tower UPS units
55941AX RT1.5kVA 2U Rack or Tower UPS (100-125VAC)
55941KX RT1.5kVA 2U Rack or Tower UPS (200-240VAC)
55942AX RT2.2kVA 2U Rack or Tower UPS (100-125VAC)
55942KX RT2.2kVA 2U Rack or Tower UPS (200-240VAC)
55943AX RT3kVA 2U Rack or Tower UPS (100-125VAC)
55943KX RT3kVA 2U Rack or Tower UPS (200-240VAC)
55945KX RT5kVA 3U Rack or Tower UPS (200-240VAC)
55946KX RT6kVA 3U Rack or Tower UPS (200-240VAC)
55948KX RT8kVA 6U Rack or Tower UPS (200-240VAC)
55949KX RT11kVA 6U Rack or Tower UPS (200-240VAC)
55948PX RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55949PX RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
Rack-mounted UPS units
53951AX 1500VA LCD 2U Rack UPS (100V/120V)
53951KX 1500VA LCD 2U Rack UPS (230V)
53952AX 2200VA LCD 2U Rack UPS (100V/120V)
53952KX 2200VA LCD 2U Rack UPS (230V)
53953AX 3000VA LCD 3U Rack UPS (100 V/120 V)
53953JX 3000VA LCD 3U Rack UPS (200 V/208 V)
53956AX 6000VA LCD 4U Rack UPS (200 V/208 V)
53956KX 6000VA LCD 4U Rack UPS (230 V)
53959KX 11000VA LCD 5U Rack UPS (200V/208V/230V)
24195KX UPS5000
21303RX UPS 7500XHV
21304RX UPS 10000XHV


For more information, see the list of Lenovo Press Product Guides in the Power infrastructure category at this website:
http://lenovopress.com/systemx/power

Power distribution units

The server supports attachments to the power distribution units (PDUs) are listed in the following table.

Table 35. Power distribution units

Part number Description
Switched and Monitored PDUs
46M4002 1U 9 C19/3 C13 Active Energy Manager DPI PDU
46M4003 1U 9 C19/3 C13 Active Energy Manager 60A 3 Phase PDU
46M4004 1U 12 C13 Active Energy Manager DPI PDU
46M4005 1U 12 C13 Active Energy Manager 60A 3 Phase PDU
46M4167 1U 9 C19/3 C13 Switched and Monitored 30A 3 Phase PDU
46M4116 0U 24 C13 Switched and Monitored 30A PDU
46M4119 0U 24 C13 Switched and Monitored 32A PDU
46M4134 0U 12 C19/12 C13 Switched and Monitored 50A 3 Phase PDU
46M4137 0U 12 C19/12 C13 Switched and Monitored 32A 3 Phase PDU
Enterprise PDUs
71762MX Ultra Density Enterprise PDU C19 PDU+ (WW)
71762NX Ultra Density Enterprise PDU C19 PDU (WW)
71763MU Ultra Density Enterprise PDU C19 3 Phase 60A PDU+ (NA)
71763NU Ultra Density Enterprise PDU C19 3 Phase 60A PDU (NA)
39M2816 DPI C13 Enterprise PDU without line cord
39Y8923 DPI 60A Three Phase C19 Enterprise PDU with IEC309 3P+G (208 V) fixed line cord
39Y8941 DPI Single Phase C13 Enterprise PDU without line cord
39Y8948 DPI Single Phase C19 Enterprise PDU without line cord
Front-end PDUs
39Y8934 DPI 32 amp/250 V Front-end PDU with IEC 309 2P+Gnd connector
39Y8935 DPI 63 amp/250 V Front-end PDU with IEC 309 2P+Gnd connector
39Y8938 30 amp/125 V Front-end PDU with NEMA L5-30P connector
39Y8939 30 amp/250 V Front-end PDU with NEMA L6-30P connector
39Y8940 60 amp/250 V Front-end PDU with IEC 309 60A 2P+N+Gnd connector
Universal PDUs
39Y8951 DPI Universal Rack PDU with US LV and HV line cords
39Y8952 DPI Universal Rack PDU with CEE7-VII Europe LC
39Y8953 DPI Universal Rack PDU with Denmark LC
39Y8954 DPI Universal Rack PDU with Israel LC
39Y8955 DPI Universal Rack PDU with Italy LC
39Y8956 DPI Universal Rack PDU with South Africa LC
39Y8957 DPI Universal Rack PDU with UK LC
39Y8958 DPI Universal Rack PDU with AS/NZ LC
39Y8959 DPI Universal Rack PDU with China LC
39Y8962 DPI Universal Rack PDU (Argentina)
39Y8960 DPI Universal Rack PDU (Brazil)
39Y8961 DPI Universal Rack PDU (India)
0U Basic PDUs
46M4122 0U 24 C13 16A 3 Phase PDU
46M4125 0U 24 C13 30A 3 Phase PDU
46M4128 0U 24 C13 30A PDU
46M4131 0U 24 C13 32A PDU
46M4140 0U 12 C19/12 C13 60A 3 Phase PDU
46M4143 0U 12 C19/12 C13 32A 3 Phase PDU


For more information, see the list of Lenovo Press Product Guides in the Power infrastructure category at this website:
http://lenovopress.com/systemx/power

Rack options

The x3500 M5 server can be installed in the rack with the Tower to Rack Conversion Kit (00AL538). The resulting server is a 5U rack-mountable server, as shown in the following figure.


Figure 15. The x3500 M5 with the 5U Tower to Rack Conversion Kit (included slide kit shown)

The Tower to Rack Conversion Kit (00AL538) includes a cable management arm; however, standard rack models (for example, 5464-C3x and G3x) do not include a cable management arm. Thefore, the arm must be ordered separately by using part number 00KC334.

The tower-to-rack conversion kit, supported cable management arm kit, rack console switches, monitor kits, and management gateways are listed in the following table.

Table 36. Rack options

Part number Feature code Description
Rack options for the x3500 M5
00KC334 ARZ2 System x3500 M5 Cable Management Kit
00AL538 A5N4 System x3500 M5 Tower to Rack Conversion Kit
Monitor kits and keyboard trays
17238BX 1723HC1 fc A3EK 1U 18.5" Standard Console
17238EX 1723HC1 fc A3EL 1U 18.5" Enhanced Media Console
Console switches
1754D2X 1754HC2 fc 6695 Global 4x2x32 Console Manager (GCM32)
1754D1X 1754HC1 fc 6694 Global 2x2x16 Console Manager (GCM16)
1754A2X 1754HC4 fc 0726 Local 2x16 Console Manager (LCM16)
1754A1X 1754HC3 fc 0725 Local 1x8 Console Manager (LCM8)
Console cables
43V6147 3757 Single Cable USB Conversion Option (UCO)
39M2895 3756 USB Conversion Option (4 Pack UCO)
46M5383 5341 Virtual Media Conversion Option Gen2 (VCO2)
46M5382 5340 Serial Conversion Option (SCO)
Universal management gateway and cables
3858D3X 3858HC1 fc A4X1 Avocent Universal Management Gateway 6000
00AK142 A4X4 UM KVM Module VGA+SD Dual RJ45


For more information, see the list of Lenovo Press Product Guides in the Rack cabinets and options category at this website:
http://lenovopress.com/systemx/rack

Rack cabinets

Supported rack cabinets are listed in the following table.

Table 37. Rack cabinets

Part number Description
Tower to rack conversion kits
00KC334 System x3500 M5 Cable Management Kit
00AL538 System x3500 M5 Tower to Rack Conversion Kit
Rack cabinets
201886X 11U Office Enablement Kit
93072RX 25U Standard Rack
93072PX 25U Static S2 Standard Rack
93634EX 42U 1100mm Dynamic Expansion Rack
93634PX 42U 1100mm Dynamic Rack
93604EX 42U 1200mm Deep Dynamic Expansion Rack
93604PX 42U 1200mm Deep Dynamic Rack
93614EX 42U 1200mm Deep Static Expansion Rack
93614PX 42U 1200mm Deep Static Rack
93084EX 42U Enterprise Expansion Rack
93084PX 42U Enterprise Rack
93074RX 42U Standard Rack
93074XX 42U Standard Rack Extension
93624EX 47U 1200mm Deep Static Expansion Rack
93624PX 47U 1200mm Deep Static Rack
93634BX PureFlex® System 42U Expansion Rack
93634DX PureFlex System 42U Expansion Rack
93634AX PureFlex System 42U Rack
93634CX PureFlex System 42U Rack


For more information, see the list of Lenovo Press Product Guides in the Rack cabinets and options category at this website:
http://lenovopress.com/systemx/rack

Bảo mật thông tin | Đổi, trả hàng và hoàn tiền | Bảo hành | Vận chuyển, giao nhận | Hình thức thanh toán
Copyright © 2007 - 2014 | Công ty Cổ phần Phát triển Giải pháp Công nghệ THT
MST: 0102266369 | Giấy phép ĐKKD số: 0103017419 cấp ngày 21-05-2007
Tel: 096 450 7700 / 096 458 7700 / + 84 4 32001015 | Email: info@thts.vn
Trụ sở: Phòng 510 nhà A11, Khu tập thể Thanh Xuân, P.Thanh Xuân Bắc, Q.Thanh Xuân, TP.Hà Nội
VP HN: P.805, 57 Vũ Trọng Phụng, Thanh Xuân, Hà Nội, Việt Nam
VP HCM: Phòng 502, 18B Nam Quốc Cang, Quận 1, Hồ Chí Minh
Người chịu trách nhiệm quản lý nội dung: Lê Hải Tú