Components
|
Specification
|
Form factor
|
Tower or 5U Rack. |
Processor
|
Xeon 8C E5-2630v3 85W 2.4GHz/1866MHz/20MB/ Up to two 18-core Intel Xeon processors E5-2600 v3 series |
Cache
|
Up to 45 MB per processor |
Memory (Max)
|
16GB TruDDR4 Memory (1Rx4, 1.2V) PC4-17000 CL15 2133MHz LP RDIMM/ Up to 1.5 TB with 64 GB* TruDDR4 Memory LRDIMMs. |
Disk drive bays
|
Up to 32 2.5-inch hot-swap hard disk drives (HDDs) or solid-state drives (SSDs), or up to 12 3.5-inch hot-swap HDDs or 6 3.5-inch simple-swap HDDs, or a combination of up to 16 2.5-inch hot-swap HDDs/SSDs with up to 6 3.5-inch hot-swap HDDs |
Maximum internal storage
|
72 TB with 12x 6TB 3.5-inch NL SAS or NL SATA hot-swap HDDs
51.2 TB with 32x 1.6TB 2.5-inch SAS hot-swap SSDs
38.4 TB with 32x 1.2TB 2.5-inch SAS hot-swap HDDs
36 TB with 6x 6TB 3.5-inch NL SAS or NL SATA simple-swap HDDs
Intermix of SAS and SATA is supported. |
RAID Support
|
IBM ServeRAID M1215 RAID/ 12 Gbps hardware dual RAID adapters -0, -1, -10 with optional RAID-5, -50, -6, -60 upgrades |
Optical drive bays
|
Two half-height 5.25-inch bays for optical or tape drives. Supports DVD-ROM or Multiburner. |
Tape drive bays
|
Two half-height 5.25-inch bays for optical or tape drives. Support for one RDX internal USB tape drive. |
Network interfaces
|
Quad-port Gigabit Ethernet and single-port IMM standard; optional 10 GbE PCIe adapters available |
PCI Expansion slots
|
Up to seven PCIe 3.0 expansion slots; support for up to two 300 W GPUs |
Power supply
|
1/2 PS Redundant 550 W AC/ hot-swap redundant 550 W/750 W/900 W, 80 PLUS Platinum or 750 W 80 PLUS Titanium |
Hot-swap parts
|
Hard drives, power supplies, and fans |
Systems management
|
IMM2 with dedicated management port (optional remote presence); Predictive Failure Analysis, Diagnostic LEDs, light path diagnostics, IBM Systems Director and IBM Systems Director Active Energy Manager |
Security features
|
Power-on password, administrator's password, two TPMs: On the IMM2.1 (TPM 1.2) and on the host (TPM 1.2/2.0). Lockable front bezel. |
Operating systems supported
|
Microsoft Windows Server , Red Hat Enterprise Linux, SUSE Linux Enterprise, VMware vSphere - (Optional USB Key or SD Media Adapter*) |
Limited warranty
|
3-year customer replaceable unit and onsite limited warranty, next business day 9x5, service upgrades available |
Introduction
The Lenovo System x3500 M5 server provides outstanding performance for your business-critical applications. Its energy-efficient design supports more cores, memory, and data capacity in a scalable Tower or 5U Rack package that is easy to service and manage. With more computing power per watt and the latest Intel Xeon E5-2600 v3 processors, you can reduce costs while maintaining speed and availability.
Suggested use: business-critical workloads, cloud computing, virtualization, virtual desktop, big data, analytics, SAP applications, database management, point of sale
Figure 1 shows the System x3500 M5.
Figure 1. The Lenovo System x3500 M5
Did you know?
The x3500 M5 offers a flexible, scalable design and simple upgrade path to 32 HDDs, with up to seven PCIe 3.0 slots and up to 1.5 TB of memory. The onboard Ethernet solution provides four standard integrated Gigabit Ethernet ports without occupying PCIe slots. Comprehensive systems management tools with the next-generation Integrated Management Module II make it easy to deploy, integrate, service, and manage.
Key features
A high-performance dual-socket tower server, the Lenovo System x3500 M5 can deliver the scalability, reliable performance, and optimized efficiency for your business-critical applications. Start with the basics and upgrade as your business changes without jeopardizing existing investments. Virtualizing the PC infrastructure into one server can provide access to a powerful server with abundant storage space, while significantly reducing IT costs.
Scalability and performance
The x3500 M5 offers the following features to boost performance, improve scalability, and reduce costs:
- Improves productivity by offering superior system performance with up to two processors (each with up to 18 cores), up to 45 MB of L3 cache, and up to 9.6 GT/s QPI interconnect links.
- Supports up to two processors, 36 cores, and 72 threads maximize the concurrent execution of multi-threaded applications.
- Intelligent and adaptive system performance with energy efficient Intel Turbo Boost Technology allows CPU cores to run at maximum speeds during peak workloads by temporarily going beyond processor thermal design power (TDP).
- Intel Hyper-Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core, up to two threads per core.
- Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads.
- Intel Advanced Vector Extensions 2.0 (AVX 2.0) enable acceleration of enterprise-class workloads, including databases, and enterprise resource planning.
- Up to 2133 MHz memory speeds with two DIMMs per channel that are running at 2133 MHz to help maximize system performance.
- Up to 1.5 TB of memory capacity with 64 GB load-reduced DIMMs, or LRDIMMs (support for 64 GB LRDIMMs is planned for a later date).
- The 12 Gbps SAS internal storage connectivity doubles the data transfer rate compared to 6 Gb SAS solutions to maximize performance of storage I/O-intensive applications.
- Up to 32 drive bays with internal backup and optical drive at the same time provide a flexible and scalable all-in-one platform to meet increasing demands.
- Flexible and scalable internal storage configurations provide for up to 72 TB of storage capacity.
- The use of solid-state drives (SSDs) instead of or along with traditional spinning hard disk drives (HDDs) can significantly improve I/O performance. An SSD can support up to 100 times more I/O operations per second (IOPS) than a typical HDD.
- The server has four integrated Gigabit Ethernet ports.
- The server offers up to seven PCI Express (PCIe) 3.0 I/O expansion slots.
- With Intel Integrated I/O Technology, the PCI Express 3.0 controller is integrated into the Intel Xeon processor E5 family. This integration helps to dramatically reduce I/O latency and increase overall system performance.
- Support for up to two NVIDIA Quadro graphics processing units (GPUs) to maximize computing power.
Availability and serviceability
The x3500 M5 provides the following features to simplify serviceability and increase system uptime:
- The server offers Chipkill, memory mirroring, and memory rank sparing for redundancy in the event of a non-correctable memory failure.
- Tool-less cover removal provides easy access to upgrades and serviceable parts, such as CPU, memory, and adapter cards.
- Offers hot-swap drives that support RAID redundancy for data protection and greater system uptime.
- Supports the ability to have redundant hot-swap power supplies and redundant hot-swap fans to provide availability for business-critical applications.
- The optional light path diagnostics panel and individual light path LEDs quickly lead the technician to failed (or failing) components. This feature simplifies servicing, speeds up problem resolution, and helps improve system availability.
- Predictive Failure Analysis (PFA) detects when system components (processors, VRMs, memory, disks, fans, and power supplies) operate outside of standard thresholds and generates proactive alerts in advance of possible failure, which increases uptime.
- SSDs offer significantly better reliability than traditional mechanical HDDs for greater uptime.
- Built-in Integrated Management Module II (IMM2.1) continuously monitors system parameters, triggers alerts, and performs recovery actions if there is a failure to minimize downtime.
- Built-in diagnostics by using Dynamic Systems Analysis (DSA) Preboot speeds up troubleshooting tasks to reduce service time.
- Three-year customer replaceable unit and onsite limited warranty; next business day 9x5. Optional service upgrades available.
Manageability and security
The following powerful systems management features simplify local and remote management of the x3500 M5:
- The server includes an IMM2.1 to monitor server availability and perform remote management.
- Integrated industry-standard Unified Extensible Firmware Interface (UEFI) enables improved setup, configuration, and updates and simplifies error handling.
- Two integrated Trusted Platform Modules (TPMs) enable advanced cryptographic functionality, such as digital signatures and remote attestation.
- System x Trusted Platform Assurance, an exclusive set of System x security features and practices, establishes a foolproof security foundation for workloads by delivering firmware that is securely built, tested, digitally signed, and verified before running.
- The server offers enterprise-class data protection with optional self-encrypting drives and simple, centralized key management through IBM Security Key Lifecycle Management.
- Industry-standard AES NI support offers faster, stronger encryption.
- IBM Systems Director offers comprehensive systems management tools that help to increase uptime, reduce costs, and improve productivity through advanced server management capabilities.
- Intel Execute Disable Bit functionality can help prevent certain classes of malicious buffer overflow attacks when combined with a supporting operating system.
- Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, which allows an application to run in its own isolated space that is protected from all other software running on a system.
Energy efficiency
The x3500 M5 offers the following energy-efficiency features to save energy, reduce operational costs, increase energy availability, and contribute to the green environment:
- Energy-efficient planar components help lower operational costs.
- High-efficiency power supplies with 80 PLUS Platinum and Titanium certifications.
- Intel Intelligent Power Capability powers individual processor elements on and off as needed to reduce power draw.
- The Intel Xeon processor E5-2600 v3 product families offer significantly better performance over the previous generation while fitting into the same thermal design power (TDP) limits.
- Intel Intelligent Power Capability powers individual processor elements on and off as needed to reduce power draw.
- Low-voltage Intel Xeon processors draw less energy to satisfy demands of power and thermally constrained data centers and telecommunication environments.
- Low-voltage 1.2 V DDR4 memory DIMMs use up to 20% less energy compared to 1.35 V DDR3 DIMMs.
- SSDs use as much as 80% less power than traditional spinning 2.5-inch HDDs.
- The server uses hexagonal ventilation holes, which is a part of Calibrated Vectored Cooling™ technology. Hexagonal holes can be grouped more densely than round holes, which provides more efficient airflow through the system.
- IBM Systems Director Active Energy Manager™ provides advanced data center power notification and management to help achieve lower heat output and reduced cooling needs.
Locations of key components and connectors
The following figure shows the front of the server.
Figure 2. Front view of the System x3500 M5
The following figure shows the rear of the server.
Figure 3. Rear view of the System x3500 M5
The following figure shows the locations of key components inside the server.
Figure 4. Inside view of the System x3500 M5
Standard specifications
The following table lists the standard specifications.
Table 1. Standard specifications
Components |
Specification |
Machine type |
5464 |
Form factor |
Tower or 5U Rack. |
Processor |
Up to two Intel Xeon processor E5-2600 v3 product family CPUs with 18 cores (2.8 GHz core speeds); or 14 cores (2.6 GHz), 12 cores (up to 2.6 GHz), 10 cores (2.3 GHz), 8 cores (up to 3.2 GHz), 6 cores (up to 2.4 GHz), 4 cores (3.0 GHz)
Two QPI links up to 9.6 GT/s each. Up to 2133 MHz memory speed. Up to 45 MB L3 cache. |
Chipset |
Intel C612. |
Memory |
Up to 24 DIMM sockets (12 DIMMs per processor). RDIMMs and LRDIMMs are supported. Memory types cannot be intermixed. Memory speed up to 2133 MHz. |
Memory maximums |
With RDIMMs: Up to 384 GB with 24x 16 GB RDIMMs and two processors
With LRDIMMs: Up to 1.5 TB with 24x 64 GB LRDIMMs and two processors |
Memory protection |
ECC, Chipkill (for x4-based memory DIMMs), memory mirroring, and memory rank sparing |
Disk drive bays |
Available configurations:
- Up to 32x 2.5-inch hot-swap SAS/SATA HDDs
- Up to 12x 3.5-inch hot-swap SAS/SATA HDDs or SSDs
- Up to 6x 3.5-inch hot-swap HDDs + 16x 2.5-inch hot-swap drives HDDs/SSDs
- Up to 6x 3.5-inch simple-swap SATA HDDs
Additional drive bays for the above configurations:
- Two 5.25-inch drive bays for optical drives
|
Maximum internal storage |
- 72 TB with 12x 6TB 3.5-inch NL SAS or NL SATA hot-swap HDDs
- 51.2 TB with 32x 1.6TB 2.5-inch SAS hot-swap SSDs
- 38.4 TB with 32x 1.2TB 2.5-inch SAS hot-swap HDDs
- 36 TB with 6x 6TB 3.5-inch NL SAS or NL SATA simple-swap HDDs
- Intermix of SAS and SATA is supported.
|
Storage controller |
- Onboard 6 Gb SATA: no RAID support
- 12 Gb SAS/SATA RAID: RAID 0, 1, 10 with M1215 or M5210. Optional upgrade to RAID 5, 50 is available for M1215. Optional upgrade to RAID 5, 50 is available for M5210 (zero-cache; 1 GB non-backed cache; 1 GB, 2 GB or 4 GB flash-backed cache). Optional upgrade to RAID 6, 60 is available for M5210 with memory cache upgrades.
- 12 Gb SAS/SATA non-RAID: N2215 HBA
|
Optical drive bays |
Two half-height 5.25-inch bays for optical or tape drives. Supports DVD-ROM or Multiburner. |
Tape drive bays |
Two half-height 5.25-inch bays for optical or tape drives. Support for one RDX internal USB tape drive. |
Network interfaces |
Four integrated Gigabit Ethernet 1000BASE-T ports (RJ-45) based on Broadcom BCM5719 controller |
PCI Expansion slots |
Up to seven slots with two processors and four slots when one CPU is installed. All slots are PCIe 3.0 slots:
- Slot 1: PCIe 3.0 x8 (x8 wired); full-height, half-length
- Slot 2: PCIe 3.0 x16 (x8 wired); full-height, full-length
- Slot 3: PCIe 3.0 x16 (x16 wired); full-height, full-length
- Slot 4: PCIe 3.0 x8 (x8 wired); full-height, full-length
- Slot 5: PCIe 3.0 x8 (x8 wired); full-height, half-length (requires second processor)
- Slot 6: PCIe 3.0 x16 (x16 wired); full-height, full-length (requires second processor)
- Slot 7: PCIe 3.0 x16 (x16 wired) full-height, full-length (requires second processor)
Slots 3 and 6 support double-wide GPUs |
Ports |
- Front: Two USB 2.0 ports
- Rear: Four USB ports (two USB 2.0, two USB 3.0), one DB-15 video, one RJ-45 systems management, four RJ-45 GbE network ports, optional serial port.
- Internal: Two internal USB 3.0 ports (for embedded hypervisor and internal tape drive). Optional SD Media Adapter.
|
Cooling |
Calibrated Vectored Cooling with up to four hot-swap fans (two fans shipped standard on single processor models and four fans shipped on dual processor models). For single-processor models, optional Redundant Cooling Kit provides two extra fans for N+1 redundancy. |
Power supply |
Up to two redundant hot-swap 550 W, 750 W or 900 W High Efficiency Platinum AC power supplies, or 750 W High Efficiency Titanium AC power supplies. |
Hot-swap parts |
Hard drives, power supplies, and fans |
Systems management |
UEFI, IMM2.1 that is based on Renesas SH7758, Predictive Failure Analysis, light path diagnostics panel on the front of the server with optional upgrade kit, Automatic Server Restart, ToolsCenter, Systems Director and Active Energy Manager. Optional IMM Advanced Upgrade software feature for remote presence. |
Security features |
Power-on password, administrator's password, two TPMs: On the IMM2.1 (TPM 1.2) and on the host (TPM 1.2/2.0). Lockable front bezel. |
Video |
Matrox G200eR2 with 16 MB memory integrated into the IMM2.1. Maximum resolution is 1600x1200 at 75 Hz with 16 M colors. |
Operating systems supported |
Microsoft Windows Server 2012 R2, 2012 and 2008 R2, Red Hat Enterprise Linux 6 and 7, SUSE Linux Enterprise Server 11, VMware vSphere (ESXi) 5.1 and 5.5. |
Limited warranty |
Three-year customer-replaceable unit and onsite limited warranty with 9x5/NBD. |
Service and support |
Optional service upgrades are available through Lenovo: 4-hour or 2-hour response time, 8-hour fix time, 1-year or 2-year warranty extension, remote technical support for Lenovo hardware and selected Lenovo and third-party (Microsoft, Linux, VMware) software. |
Dimensions |
Tower: Width: 218 mm (8.6 in), depth: 720 mm (28.3 in), height: 440 mm (17.25 in).
With rack conversion kit: Width: 423 mm (16.6 in), depth: 706 mm (27.8 in), height: 218 mm (8.6 in ) |
Weight |
Tower: 45.5 kg (100.3 lb) fully configured, 30.8 kg (67.9 lb) minimum configuration
With rack conversion kit: 44.2 kg (97.4 lb) fully configured, 29.5 kg (65 lb) minimum configuration |
The x3500 M5 servers are shipped with the following items:
- Statement of Limited Warranty
- Important Notices
- Registration flyer
- Documentation CD that contains the Installation and User's Guide
- One 2.8 m C13 line cord (country-specific)
Notes:
- Rack models include a rail kit but do not include a cable management arm. Order the CMA separately by using part number 00KC334.
- EMEA models do not contain line cord. It must be purchased separately.
Standard models
The following table lists the standard models.
Table 2. Standard models
MTM* |
Intel Xeon processors†
(two maximum) |
Memory |
RAID |
Drive bays
(std / max) |
Drives |
Slots
(std /
max) |
GbE |
Optical |
Power
supply
(std / max) |
Tower models |
5464-
A2x |
1x E5-2603 v3 6C 1.6GHz
15MB 1600MHz 85W |
1x 8 GB |
M1215 |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
4 |
DVD |
1x 550 W
HS / 2 |
5464-
B2x |
1x E5-2609 v3 6C 1.9GHz
15MB 1600MHz 85W |
1x 8 GB |
M1215 |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
4 |
DVD |
1x 550 W
HS / 2 |
5464-
C2x |
1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W |
1x 16 GB |
M1215 |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
4 |
DVD |
1x 550 W
HS / 2 |
5464-
C4x |
1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W |
1x 16 GB |
M1215 |
6x 3.5-inch
HS / 12 |
Open |
4 / 7 |
4 |
DVD |
1x 550 W
HS / 2 |
5464-
D2x |
1x E5-2630 v3 8C 2.4GHz
20MB 1866MHz 85W |
1x 16 GB |
M1215 |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
4 |
DVD |
1x 550 W
HS / 2 |
5464-
G2x |
1x E5-2650 v3 10C 2.3GHz
25MB 2133MHz 105W |
1x 16 GB |
M5210 1GB
Flash |
8x 2.-inch
HS / 32 |
Open |
4 / 7 |
4 |
DVD |
1x 750 W
HS / 2 |
5464-
H2x |
1x E5-2670 v3 12C 2.3GHz
30MB 2133MHz 120W |
1x 16 GB |
M5210 2GB
Flash |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
4 |
DVD |
1x 900 W
HS / 2 |
5464-
J2x |
1x E5-2680 v3 12C 2.5GHz
30MB 2133MHz 120W |
1x 16 GB |
M5210 2GB
Flash |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
4 |
DVD |
1x 900 W
HS / 2 |
Rack models |
5464-
C3x |
1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W |
1x 16 GB |
M1215 |
6x 3.5-inch
HS / 12 |
Open |
4 / 7 |
4 |
DVD |
1x 550 W
HS / 2 |
5464-
G3x |
1x E5-2650 v3 10C 2.3GHz
25MB 2133MHz 105W |
1x 16 GB |
M5210 1GB
Flash |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
4 |
DVD |
1x 750 W
HS / 2 |
* x in the Machine Type Model (MTM) represents a country-specific letter (for example, the EMEA MTM is 7983-A5G, and the US MTM is 7383-A5U). Ask a Lenovo representative for specific information.
† Processor detail: Processor quantity and model, cores, core speed, L3 cache, memory speed, TDP.
Refer to the Specifications section for information about standard features of the server.
TopSeller and Express models
The following table lists the express models.
Table 3. Express models
MTM**
Form
factor |
Intel Xeon processors†
(two maximum) |
Memory |
RAID |
Drive
bays
(std / max) |
Drives |
Slots
(std /
max) |
Optical |
Power
supply
(2 max) |
United States and Canada |
5464-EAU
Tower |
1x E5-2609 v3 6C 1.9GHz
15MB 1600MHz 85W |
1x 8 GB |
M1215 |
6x 3.5-inch
HS / 12 |
Open |
4 / 7 |
Multi-
burner |
1x 550W |
5464-EBU
Tower |
1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W |
1x 16 GB |
M5120 |
6x 3.5-inch
HS / 12 |
Open |
4 / 7 |
Multi-
burner |
1x 750W |
5464-ECU
Tower |
1x E5-2640 v3 8C 2.6GHz
20MB 1866MHz 90W |
1x 16 GB |
M5120 |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
Multi-
burner |
1x 750W |
5464-EDU
Tower |
2x E5-2609 v3 6C 1.9GHz
15MB 1600MHz 85W |
2x 16 GB |
M5120 2GB
Flash |
6x 3.5-inch
HS / 12 |
Open |
4 / 7 |
Multi-
burner |
2x 550W |
5464-EEU
Tower |
2x E5-2640 v3 8C 2.6GHz
20MB 1866MHz 90W |
2x 16 GB |
M5120 2GB
Flash |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
Multi-
burner |
2x 750W |
Europe, Middle East & Africa (EMEA) |
5464-E1G
Tower |
1x E5-2603 v3 6C 1.6GHz
15MB 1600MHz 85W |
|
M1215 +
RAID 5/50 |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
Multi-
burner |
1x 550W |
5464-E2G
Tower |
1x E5-2609 v3 6C 1.9GHz
15MB 1600MHz 85W |
1x 8 GB |
M1215 +
RAID 5/50 |
6x 3.5-inch
HS / 12 |
Open |
4 / 7 |
Multi-
burner |
1x 550W |
5464-E3G
Tower |
1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W |
1x 8 GB |
M5120 1GB
No backup |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
Multi-
burner |
2x 550W |
5464-E4G
Tower |
1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W |
1x 8 GB |
M5120 1GB
Flash |
8x 2.5-inch
HS / 32 |
3x 300GB
10K SAS |
4 / 7 |
Multi-
burner |
2x 750W |
5464-E5G
Tower |
1x E5-2640 v3 8C 2.6GHz
20MB 1866MHz 90W |
1x 16 GB |
M5120 2GB
Flash |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
Multi-
burner |
2x 750W |
Latin America & Brazil |
5464-EFx
Tower |
1x E5-2609 v3 6C 1.9GHz
15MB 1600MHz 85W |
1x 8 GB |
M5120 1GB
Flash+Cap |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
DVD |
1x 550W |
5464-EGx
Tower |
1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W |
1x 16 GB |
M5120 1GB
Flash |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
DVD |
1x 550W |
5464-EHx
Tower |
1x E5-2650 v3 10C 2.3GHz
25MB 2133MHz 105W |
1x 16 GB |
M5120 1GB
Flash |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
DVD |
1x 750W |
Japan |
5464-E6J
Tower |
1x E5-2603 v3 6C 1.6GHz
15MB 1600MHz 85W |
1x 8 GB |
M5120 1GB
Flash |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
DVD |
1x 550W |
5464-E7J
Tower |
1x E5-2609 v3 6C 1.9GHz
15MB 1600MHz 85W |
1x 8 GB |
M5120 1GB
Flash |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
DVD |
1x 550W |
Australia & New Zealand |
5464-EIM
Tower |
1x E5-2609 v3 6C 1.9GHz
15MB 1600MHz 85W |
1x 8 GB |
M1215 +
RAID 5/50 |
6x 3.5-inch
HS / 12 |
Open |
4 / 7 |
Multi-
burner |
1x 550W |
5464-EJM
Tower |
1x E5-2609 v3 6C 1.9GHz
15MB 1600MHz 85W |
1x 8 GB |
M1215 +
RAID 5/50 |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
Multi-
burner |
1x 550W |
5464-EKM
Tower |
1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W |
2x 8 GB |
M5120 1GB
Flash+Cap |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
Multi-
burner |
1x 550W |
5464-ELM
Tower |
1x E5-2640 v3 8C 2.6GHz
20MB 1866MHz 90W |
2x 8 GB |
M5120 1GB
Flash+Cap |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
Multi-
burner |
1x 750W |
** MTM = Machine Type Model
† Processor detail: Processor quantity and model, number of cores, core speed, L3 cache, memory speed, TDP.
Table 4. TopSeller Models
MTM**
Form
factor |
Intel Xeon processors†
(two maximum) |
Memory |
RAID |
Drive
bays
(std / max) |
Drives |
Slots
(std /
max) |
Optical |
Power
supply
(2 max) |
United States and Canada |
5464-NAY
Tower |
1x E5-2603 v3 6C 1.6GHz
15MB 1600MHz 85W |
1x 8 GB |
M1215 |
6x 3.5-inch
HS / 12 |
Open |
4 / 7 |
Open |
1x 550W |
5464-NBY
Tower |
1x E5-2609 v3 6C 1.9GHz
15MB 1600MHz 85W |
1x 8 GB |
M1215 |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
Open |
1x 550W |
5464-NCY
Tower |
1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W |
1x 16 GB |
M1215 |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
Open |
1x 550W |
5464-NDY
Tower |
1x E5-2630 v3 8C 2.4GHz
20MB 1866MHz 85W |
1x 16 GB |
M5120 |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
Open |
1x 550W |
5464-NEY
Tower |
1x E5-2630 v3 8C 2.4GHz
20MB 1866MHz 85W |
1x 16 GB |
M5120 |
6x 3.5-inch
HS / 12 |
Open |
4 / 7 |
Open |
1x 550W |
5464-NFY
Tower |
1x E5-2650 v3 10C 2.3GHz
25MB 2133MHz 105W |
1x 16 GB |
M5120 |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
Open |
1x 750W |
Europe, Middle East, and Africa (EMEA) |
5464-K1G |
1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W |
1x 16 GB |
M5210 2GB
Flash |
8x 2.5-inch
HS / 32 |
Open |
4 / 7 |
Multi-
burner |
1x 550W |
Processor options
The x3500 M5 supports the processor options that are listed in the following table. The server supports up to two processors. This table shows which server models feature each processor as standard. If there is no corresponding where-used model for a particular processor, this processor is available through CTO only.
Table 5. Processor options
Part
number |
Feature
codes* |
Description |
Standard models
where used |
81Y7113 |
A5C8 / A5MP |
Intel Xeon E5-2603 v3 6C 1.6GHz 15MB 1600MHz 85W |
A2x |
81Y7114 |
A5C9 / A5MQ |
Intel Xeon E5-2609 v3 6C 1.9GHz 15MB 1600MHz 85W |
B2x |
81Y7115 |
A5CA / A5MR |
Intel Xeon E5-2620 v3 6C 2.4GHz 15MB 1866MHz 85W |
C2x, C3x, C4x |
00MU332 |
ASLW / ASLZ |
Intel Xeon E5-2623 v3 4C 3.0GHz 10MB 1866MHz 105W |
- |
81Y7116 |
A5CB / A5MS |
Intel Xeon E5-2630 v3 8C 2.4GHz 20MB 1866MHz 85W |
D2x |
00KG052 |
ARZK / ARZL |
Intel Xeon E5-2630L v3 8C 1.8GHz 20MB 1866MHz 55W |
- |
81Y7117 |
A5CC / A5MT |
Intel Xeon E5-2640 v3 8C 2.6GHz 20MB 1866MHz 90W |
- |
81Y7118 |
A5CD / A5MU |
Intel Xeon E5-2650 v3 10C 2.3GHz 25MB 2133MHz 105W |
G2x, G3x |
81Y7121 |
A5CG / A5MX |
Intel Xeon E5-2650L v3 12C 1.8GHz 30MB 2133MHz 65W |
- |
00MU330 |
ASLU / ASLX |
Intel Xeon E5-2660 v3 12C 2.3GHz 30MB 2133MHz 105W |
- |
00MU331 |
ASLV / ASLY |
Intel Xeon E5-2667 v3 8C 3.2GHz 20MB 2133MHz 135W |
- |
81Y7119 |
A5CE / A5MV |
Intel Xeon E5-2670 v3 12C 2.3GHz 30MB 2133MHz 120W |
H2x |
81Y7120 |
A5CF / A5MW |
Intel Xeon E5-2680 v3 12C 2.5GHz 30MB 2133MHz 120W |
J2x |
00KG038 |
ARYU / ARYX |
Intel Xeon E5-2690 v3 12C 2.6GHz 30MB 2133MHz 135W |
- |
00KG039 |
ARYV / ARYY |
Intel Xeon E5-2697 v3 14C 2.6GHz 35MB 2133MHz 145W |
- |
00KG040 |
ARYW / ARYZ |
Intel Xeon E5-2699 v3 18C 2.8GHz 45MB 2133MHz 145W |
- |
* The first feature code is for the first processor; the second feature code is for the second processor.
Memory options
The System x3500 M5 supports TruDDR4 memory. TruDDR Memory uses the highest quality components that are sourced from Tier 1 DRAM suppliers and only memory that meets our strict requirements is selected. It is compatibility tested and tuned on every System x server to maximize performance and reliability. TruDDR4 Memory has a unique signature programmed into the DIMM that enables System x servers to verify whether the installed memory is qualified or supported. Because TruDDR4 Memory is authenticated, certain extended memory performance features can be enabled to extend performance over industry standards. From a service and support standpoint, System x memory automatically assumes the system's warranty, and service and support provided worldwide.
The following table lists the available memory options for the x3500 M5 server.
Table 6. Memory options
Part number |
Feature code |
Description |
Maximum supported |
Standard models
where used |
RDIMMs - 2133 MHz |
46W0784 |
A5B6 |
4GB TruDDR4 Memory (1Rx8, 1.2V) PC4-17000 CL15 2133MHz LP RDIMM |
24 (12 per CPU) |
- |
46W0788 |
A5B5 |
8GB TruDDR4 Memory (1Rx4, 1.2V) PC4-17000 CL15 2133MHz LP RDIMM |
24 (12 per CPU) |
A2x, B2x |
46W0792 |
A5B8 |
8GB TruDDR4 Memory (2Rx8, 1.2V) PC4-17000 CL15 2133MHz LP RDIMM |
24 (12 per CPU) |
|
46W0796 |
A5B7 |
16GB TruDDR4 Memory (2Rx4, 1.2V) PC4-17000 CL15 2133MHz LP RDIMM |
24 (12 per CPU) |
All other models |
LRDIMMs - 2133 MHz |
46W0800 |
A5B9 |
32GB TruDDR4 Memory (4Rx4, 1.2V) PC417000 CL15 2133MHz LP LRDIMM |
24 (12 per CPU) |
- |
95Y4812* |
A5UK |
64GB TruDDR4 Memory (4Rx4,1.2V) PC4-17000 CL15 2133MHz LP LRDIMM |
24 (12 per CPU) |
- |
* Support for 64 GB LRDIMMs is planned for a later date.
The server supports up to 12 DIMMs when one processor is installed and up to 24 DIMMs when two processors are installed. Each processor has four memory channels; there are three DIMMs per channel.
The following rules apply when the memory configuration is selected:
- The server supports RDIMMs and LRDIMMs.
- Mixing types of memory (RDIMMs and LRDIMMs) is not supported.
- The maximum quantity of DIMMs that can be installed in the server depends on the number of processors.
- All DIMMs in the server operate at the same speed, which is determined as the lowest value of the following factors:
- Memory speed that is supported by the specific processor.
- Lowest of maximum operating speeds for selected memory configuration that depends on quantity of DIMMs per channel, as shown under "Maximum operating speed" section in the following table.
The following memory protection technologies are supported:
- ECC
- Chipkill (for x4-based memory DIMMs)
- Memory mirroring
- Memory rank sparing
Chipkill works only in independent channel mode (the default is operational mode) and supports only x4-based memory DIMMs.
If memory mirroring is used, DIMMs must be installed in pairs (a minimum of one pair per each processor). Both DIMMs in a pair must be identical in type and size.
If memory rank sparing is used, a minimum of one quad-rank LRDIMM or two single-rank or dual-rank RDIMMs must be installed per populated channel (the DIMMs do not need to be identical). In rank sparing mode, one rank of a DIMM in each populated channel is reserved as spare memory. The size of a rank varies, depending on the DIMMs installed.
Chipkill, memory mirroring, and memory rank sparing modes are mutually exclusive. Only one operational memory mode can be enabled on a server, and it is a system-wide setting.
The following table shows the characteristics of the supported DIMMs. Tables cells that are highlighted with a gray background indicate when the number of DIMMs per channel still allows the DIMMs to operate at a rated speed.
Table 7. Maximum memory speeds
DIMM specification |
RDIMM
|
LRDIMM
|
Rank |
Single rank
|
Dual rank
|
Quad rank
|
Part numbers |
46W0784 (4 GB)
46W0788 (8 GB)
|
46W0792 (8 GB)
|
46W0796 (16 GB)
|
46W0800 (32 GB)
95Y4812 (64 GB)*
|
Rated speed |
2133 MHz
|
2133 MHz
|
2133 MHz
|
2133 MHz
|
Rated voltage |
1.2 V
|
1.2 V
|
1.2 V
|
1.2 V
|
Maximum quantity supported** |
24
|
24
|
24
|
24
|
Maximum DIMM capacity |
8 GB
|
8 GB
|
16 GB
|
64 GB
|
Maximum memory capacity |
192 GB
|
192 GB
|
384 GB
|
1.5 TB
|
Maximum memory at rated speed |
64 GB
|
64 GB
|
256 GB
|
512 GB
|
Maximum operating speed |
1 DIMM per channel |
2133 MHz
|
2133 MHz
|
2133 MHz
|
2133 MHz
|
2 DIMMs per channel |
2133 MHz
|
2133 MHz
|
2133 MHz
|
2133 MHz
|
3 DIMMs per channel |
1600 MHz
|
1600 MHz
|
1600 MHz
|
1866 MHz
|
* Support for 64 GB LRDIMMs is planned for a later date.
** The maximum quantity that is supported is shown for two processors installed.
Internal storage
The internal drive bays of the x3500 M5 are shown in the following figure.
Figure 5. Internal drive bays
The System x3500 M5 server supports the following internal storage configurations:
- Configurations with 2.5-inch hot-swap drives:
- 8x 2.5-inch hot-swap drives (1 RAID adapter)
- 16x 2.5-inch hot-swap drives (1 RAID adapter)
- 16x 2.5-inch hot-swap drives (2 RAID adapters)
- 24x 2.5-inch hot-swap drives (1 RAID adapter)
- 24x 2.5-inch hot-swap drives (2 RAID adapters)
- 32x 2.5-inch hot-swap drives (1 RAID adapter)
- 32x 2.5-inch hot-swap drives (2 RAID adapters)
- Configurations with 3.5-inch hot-swap drives:
- 6x 3.5-inch hot-swap hard disk drives (1 RAID adapter)
- 12x 3.5-inch hot-swap hard disk drives (2 RAID adapters)
- Configurations with 2.5-inch and 3.5-inch hot-swap drives: 6x 3.5-inch hot-swap hard disk drives + 16x 2.5-inch hot-swap drives (2 RAID adapters)
- Configurations with 3.5-inch simple-swap drives:
- 6x 3.5-inch simple-swap hard disk drives (6 Gb SATA onboard connectors)
- 6x 3.5-inch simple-swap hard disk drives (1 adapter)
-
Note: A configuration of 12 simple-swap drives is not supported.
The following drive type mixing rules apply:
- Hot-swap SATA HDDs and hot-swap SAS HDDs can be intermixed on the same backplane , but cannot be intermixed in the same RAID array.
- Hot-swap SATA HDDs and hot-swap SAS HDDs can be intermixed with SSDs on the same backplane, but SAS nor SATA HDDs can be configured with SSDs within the same RAID array.
Backplanes
The following table lists the available backplanes for the x3500 M5. Standard models ship with one 8x 2.5-inch hot-swap backplane or one 6x 3.5-inch hot-swap backplane, as listed.
Table 8. Internal storage backplane (configure to order)
Feature
code |
Name |
Models
where used |
Maximum
supported |
A5D4 |
System x3500 M5 2.5-inch Hot Swap SAS:
- 8x 2.5-inch hot-swap drives
- Connect to 1 adapter (2 ports) or 2 adapters (1 port each)
- Supported by M5210, M1215, or N2215
|
All other
standard
models |
2 |
A5N5 |
System x3500 M5 2.5-inch Hot Swap SAS 8-16:
- 8x 2.5-inch hot-swap drives
- Includes a SAS expander
- Connects to backplane A5D4 to support up to 16 drives per port
- Supported by M5210, M1215, or N2215
|
- |
2 |
A5D5 |
System x3500 M5 3.5-inch Hot Swap SAS:
- 6x 3.5-inch hot-swap drives
- Supported by M5210, M1215, or N2215
|
C3x, C4x |
2 |
A5UM |
System x3500 M5 3.5-inch Simple Swap:
- 6x 3.5-inch simple-swap drives
- Connections to onboard SATA ports
|
- |
1 |
A5D2 |
System x3500 M5 3.5-inch Simple Swap:
- 6x 3.5-inch simple-swap drives
- Connections to RAID controller
|
- |
1 |
The following table list the available hot-swap drive bay upgrades.
Table 9. Drive bay upgrade options
Option
part number |
Name |
00AL540 |
8x 2.5-inch Hot-Swap SAS/SATA Upgrade Kit for 16 or 24 HDDs:
- For existing configurations with 8x or 16x 2.5-inch bays
- Adds 8x 2.5-inch hot-swap drives
- Backplane Includes a SAS expander
- Same backplane as feature A5N5
|
00AL541 |
8x 2.5-inch Hot-Swap SAS/SATA Upgrade Kit for 32 HDDs:
- For existing configurations with 24x 2.5-inch bays
- Adds 8x 2.5-inch hot-swap drives
- Same backplane as feature A5D4
|
00AL542 |
6x 3.5-inch Hot-Swap SAS/SATA Upgrade Kit for 12 HDDs:
- For existing configurations with 6x 3.5-inch drives
- Adds 6x 3.5-inch hot-swap drives
- Same backplane as feature A5D5
|
00AL543 |
6x 3.5-inch Hot-Swap SAS/SATA Upgrade Kit for 22 HDDs (Intermix):
- For existing configurations with 16x 2.5-inch drives
- Adds 6x 3.5-inch hot-swap drives
- Same backplane as feature A5D5
|
00AL544 |
8x 2.5-inch Hot-Swap SAS/SATA Upgrade Kit for 14 HDDs (Intermix):
- For existing configurations with 6x 3.5-inch drives
- Adds 8x 2.5-inch hot-swap drives
- Same backplane as feature A5D4
|
00KG037 |
8x 2.5-inch Hot-Swap SAS/SATA Upgrade Kit for 22 HDDs (Intermix):
- For existing configurations with 6x 3.5-inch and 8x 2.5-inch drives
- Adds 8x 2.5-inch hot-swap drives
- Same backplane as feature A5N5
|
00AL539 |
SAS cable option for Dual RAID array (RAID adapter not included):
- For configurations with two RAID cards
- Only needed when upgrading from 8x 2.5-inch drives to 16, 24 or 32 drives, as shown in Figure 7.
- Connects second adapter to backplane
|
Drive bay configurations
The following figure shows how models with eight 2.5-inch drive bays can be upgraded to a total of 32 drive bays. In such configurations, all drives are connected to one RAID controller. Supported adapters are the ServeRAID M5210, ServeRAID M1215, and N2215 host bus adapter.
Figure 6. Configurations of 2.5-inch drives with one RAID adapter
The following figure shows how models with eight 2.5-inch drive bays can be upgraded to a total of 32 drive bays that use two RAID controller for added performance. Supported adapters are the ServeRAID M5210, ServeRAID M1215, and N2215 host bus adapter.
Figure 7. Configurations of 2.5-inch drives with two RAID adapters
The following figure shows how models with six 3.5-inch hot-swap drive bays can be upgraded to 12 drive bays. Such a configuration requires two RAID controllers. Supported adapters are the ServeRAID M5210, ServeRAID M1215, and N2215 host bus adapter.
Figure 8. Configurations of 3.5-inch drives
For configure-to-order configurations, the server also supports simple-swap 3.5-inch drives. The simple-swap drives can be connected to the 6 Gb SATA ports on the system board of the server or to a RAID controller. Only six 3.5-inch drives are supported; a configuration of 12 simple-swap drives is not supported.
Figure 9. Simple-swap 3.5-inch drives
The server also supports combinations of 2.5-inch drive bays (up to 16) and 3.5-inch drive bays (6 bays). The upgrade path from models with 2.5-inch drives is shown in the following figure. The 3.5-inch drives must be connected to a separate RAID adapter.
Figure 10. Combinations of 2.5-inch and 3.5-inch drive bays from a 2.5-inch base
The following figure shows the upgrade path from models with 3.5-inch drives.
Figure 11. Combinations of 2.5-inch and 3.5-inch drive bays from a 3.5-inch base
Controllers for internal storage
The following table lists the RAID controllers and additional options that are used for internal disk storage of the x3500 M5 server.
Table 10. RAID controllers and HBAs for internal storage
Part
number |
Feature
code |
Description |
Maximum
supported |
Standard models
where used |
12 Gb Controllers |
46C9114 |
A45W |
ServeRAID M1215 SAS/SATA Controller |
2 |
A2x, B2x, C2x,
C3x, C4x, D2x |
46C9110 |
A3YZ |
ServeRAID M5210 SAS/SATA Controller |
2 |
G2x, G3x, H2x, J2x |
47C8675 |
A3YY |
N2215 SAS/SATA HBA |
2 |
- |
Hardware upgrades for the M5210 |
47C8656 |
A3Z0 |
ServeRAID M5200 Series 1GB Cache/RAID 5 Upgrade |
2 |
- |
47C8660 |
A3Z1 |
ServeRAID M5200 Series 1GB Flash/RAID 5 Upgrade |
2 |
G2x, G3x |
47C8664 |
A3Z2 |
ServeRAID M5200 Series 2GB Flash/RAID 5 Upgrade |
2 |
H2x, J2x |
47C8668 |
A3Z3 |
ServeRAID M5200 Series 4GB Flash/RAID 5 Upgrade |
2 |
- |
Feature on Demand upgrades for the M1215† |
00AE930 |
A5H5 |
ServeRAID M1200 Zero Cache/RAID 5 Upgrade |
1† |
- |
Feature on Demand upgrades for the M5210† |
47C8708 |
A3Z6 |
ServeRAID M5200 Series Zero Cache/RAID 5 Upgrade |
1† |
- |
47C8706 |
A3Z5 |
ServeRAID M5200 Series RAID 6 Upgrade |
1†* |
- |
47C8710 |
A3Z7 |
ServeRAID M5200 Series Performance Accelerator |
1†* |
- |
47C8712 |
A3Z8 |
ServeRAID M5200 Series SSD Caching Enabler |
1†* |
- |
* Requires cache memory upgrade (47C8656, 47C8660, 47C8664 or 47C8668).
† Features on Demand (FoD) upgrades for ServeRAID adapters are applied system-wide; that is, one FoD upgrade is required to activate the feature on all RAID controllers of the same type installed in the server.
The ServeRAID M1215 SAS/SATA Controller has the following specifications:
- Eight internal 12 Gbps SAS/SATA ports
- Up to 12 Gbps throughput per port
- Two internal mini-SAS HD connectors (SFF-8643)
- Supports connections to SAS/SATA HDDs and SSDs
- LSI SAS3008 12 Gbps RAID on Chip (ROC) controller
- Support for RAID levels 0, 1, and 10 standard; support for RAID 5, 50 with optional FoD upgrade
- Zero Controller Cache, no battery/flash backup
- Optional support for self-encrypting drives (SEDs) with MegaRAID SafeStore (with RAID 5 upgrade)
- Fixed stripe size of 64 KB
The ServeRAID M5210 SAS/SATA Controller has the following specifications:
- Eight internal 12 Gbps SAS/SATA ports
- Up to 12 Gbps throughput per port
- Two x4 HD mini-SAS internal connectors (SFF-8643)
- Supports connections to SAS/SATA HDDs and SSDs and SAS Expanders
- Supports RAID 0, 1, and 10
- Supports RAID 5 and 50 with optional M5200 Series RAID 5 upgrades
- Supports RAID 6 and 60 with the optional M5200 Series RAID 6 upgrade
- Optional support for self-encrypting drives (SEDs) with MegaRAID SafeStore (with RAID 5 upgrade)
- Supports 1 GB non-backed cache or 1 GB, 2 GB or 4 GB flash-backed cache
- PCIe 3.0 x8 host interface
- Based on the LSI SAS3108 12 Gbps ROC controller
The N2215 SAS/SATA HBA has the following specifications:
- Eight internal 12 Gbps SAS/SATA ports
- Up to 12 Gbps throughput per port
- Two x4 HD mini-SAS internal connectors (SFF-8643)
- Supports connections to SAS/SATA HDDs and SSDs
- Optimized for SSD performance
- No RAID support
- PCIe 3.0 x8 host interface
- Based on the LSI SAS3008 12 Gbps controller
For more information, see the list of Lenovo Press Product Guides in the RAID adapters category at this website:
http://lenovopress.com/systemx/raid
Internal drive options
The following table lists hard drive options for internal disk storage of the x3500 M5 server.
Table 11. Drive options for internal disk storage
Part number |
Feature code |
Description |
Maximum supported |
3.5-inch hot-swap HDDs - 12 Gbps NL SAS |
00FN188 |
A5VP |
2TB 7.2K 12Gbps NL SAS 3.5-inch G2HS 512e HDD |
12 |
00FN208 |
A5VQ |
4TB 7.2K 12Gbps NL SAS 3.5-inch G2HS 512e HDD |
12 |
00FN228 |
A5VR |
6TB 7.2K 12Gbps NL SAS 3.5-inch G2HS 512e HDD |
12 |
3.5-inch hot-swap SEDs - 12 Gbps NL SAS |
00FN238 |
A5VS |
2TB 7.2K 12Gbps NL SAS 3.5-inch G2HS 512e SED |
12 |
00FN248 |
A5VT |
4TB 7.2K 12Gbps NL SAS 3.5-inch G2HS 512e SED |
12 |
00FN258 |
A5VU |
6TB 7.2K 12Gbps NL SAS 3.5-inch G2HS 512e SED |
12 |
3.5-inch hot-swap HDDs - 12 Gbps NL SATA |
81Y9794 |
A22T |
2TB 7.2K 6Gbps NL SATA 3.5-inch G2HS HDD |
12 |
81Y9798 |
A22S |
3TB 7.2K 6Gbps NL SATA 3.5-inch G2HS HDD |
12 |
49Y6002 |
A3W9 |
4TB 7.2K 6Gbps NL SATA 3.5-inch G2HS HDD |
12 |
3.5-inch hot-swap HDDs - 6 Gbps NL SATA |
00FN113 |
A5VD |
2TB 7.2K 6Gbps NL SATA 3.5-inch G2HS 512e HDD |
12 |
00FN128 |
A5VF |
3TB 7.2K 6Gbps NL SATA 3.5-inch G2HS 512e HDD |
12 |
00FN143 |
A5VH |
4TB 7.2K 6Gbps NL SATA 3.5-inch G2HS 512e HDD |
12 |
00FN158 |
A5VK |
5TB 7.2K 6Gbps NL SATA 3.5-inch G2HS 512e HDD |
12 |
00FN173 |
A5VM |
6TB 7.2K 6Gbps NL SATA 3.5-inch G2HS 512e HDD |
12 |
3.5-inch simple-swap HDDs - 6 Gbps NL SATA |
00FN118 |
A5VE |
2TB 7.2K 6Gbps NL SATA 3.5-inch G2SS 512e HDD |
6 |
00FN133 |
A5VG |
3TB 7.2K 6Gbps NL SATA 3.5-inch G2SS 512e HDD |
6 |
00FN148 |
A5VJ |
4TB 7.2K 6Gbps NL SATA 3.5-inch G2SS 512e HDD |
6 |
00FN163 |
A5VL |
5TB 7.2K 6Gbps NL SATA 3.5-inch G2SS 512e HDD |
6 |
00FN178 |
A5VN |
6TB 7.2K 6Gbps NL SATA 3.5-inch G2SS 512e HDD |
6 |
81Y9810 |
A22W |
2TB 7.2K 6Gbps NL SATA 3.5-inch G2SS HDD |
6 |
81Y9814 |
A22V |
3TB 7.2K 6Gbps NL SATA 3.5-inch G2SS HDD |
6 |
49Y6012 |
A3WA |
4TB 7.2K 6Gbps NL SATA 3.5-inch G2SS HDD |
6 |
2.5-inch hot-swap 15K HDDs - 12 Gbps SAS |
00AJ081 |
A4TR |
300GB 15K 6Gbps SAS 2.5-inch G3HS HDD |
32 |
00AJ126 |
A4TS |
600GB 15K 6Gbps SAS 2.5-inch G3HS HDD |
32 |
00NA221 |
ASBB |
300GB 15K 12Gbps SAS 2.5" G3HS 512e HDD |
32 |
00NA231 |
ASBD |
600GB 15K 12Gbps SAS 2.5" G3HS 512e HDD |
32 |
2.5-inch hot-swap 10K HDDs - 12 Gbps SAS |
00NA241 |
ASBF |
600GB 10K 12Gbps SAS 2.5" G3HS 512e HDD |
32 |
00NA251 |
ASBH |
900GB 10K 12Gbps SAS 2.5" G3HS 512e HDD |
32 |
00NA261 |
ASBK |
1.2TB 10K 12Gbps SAS 2.5" G3HS 512e HDD |
32 |
00NA271 |
ASBM |
1.8TB 10K 12Gbps SAS 2.5" G3HS 512e HDD |
32 |
2.5-inch hot-swap 15K HDDs - 12 Gbps SAS self-encyrpting drive (SED) |
00NA281 |
ASBP |
300GB 15K 12Gbps SAS 2.5" G3HS 512e SED |
32 |
00NA286 |
ASBQ |
600GB 15K 12Gbps SAS 2.5" G3HS 512e SED |
32 |
2.5-inch hot-swap 10K HDDs - 12 Gbps SAS SED |
00NA291 |
ASBR |
600GB 10K 12Gbps SAS 2.5" G3HS 512e SED |
32 |
00NA296 |
ASBS |
900GB 10K 12Gbps SAS 2.5" G3HS 512e SED |
32 |
00NA301 |
ASBT |
1.2TB 10K 12Gbps SAS 2.5" G3HS 512e SED |
32 |
00NA306 |
ASBU |
1.8TB 10K 12Gbps SAS 2.5" G3HS 512e SED |
32 |
2.5-inch hot-swap 15K HDDs - 12 Gbps SAS-SSD Hybrid |
00NA311 |
ASBV |
300GB 15K 12Gbps SAS 2.5" G3HS 512e Hybrid |
32 |
00NA321 |
ASBX |
600GB 15K 12Gbps SAS 2.5" G3HS 512e Hybrid |
32 |
2.5-inch hot-swap SSDs - 12 Gbps SAS - Enterprise Capacity |
00NA671 |
ASW6 |
3.84TB 6Gb SAS Enterprise Capacity G3HS MLC SSD |
32 |
2.5-inch hot-swap SSDs - 12 Gbps SAS - Enterprise |
00FN379 |
AS7C |
200GB 12G SAS 2.5-inch MLC G3HS Enterprise SSD |
32 |
00FN389 |
AS7E |
400GB 12G SAS 2.5-inch MLC G3HS Enterprise SSD |
32 |
00FN399 |
AS7G |
800GB 12G SAS 2.5-inch MLC G3HS Enterprise SSD |
32 |
00FN409 |
AS7J |
1.6TB 12G SAS 2.5-inch MLC G3HS Enterprise SSD |
32 |
2.5-inch hot-swap SSDs - 12 Gbps SAS SED - Enterprise |
00FN419 |
AS7L |
400GB SED 12G SAS 2.5-inch MLC G3HS Enterprise SSD |
32 |
00FN424 |
AS7M |
800GB SED 12G SAS 2.5-inch MLC G3HS Enterprise SSD |
32 |
2.5-inch hot-swap 10K HDDs - 6 Gbps SAS |
00AJ096 |
A4TL |
300GB 10K 6Gbps SAS 2.5-inch G3HS HDD |
32 |
00AJ091 |
A4TM |
600GB 10K 6Gbps SAS 2.5-inch G3HS HDD |
32 |
00AJ071 |
A4TN |
900GB 10K 6Gbps SAS 2.5-inch G3HS HDD |
32 |
00AJ146 |
A4TP |
1.2TB 10K 6Gbps SAS 2.5-inch G3HS HDD |
32 |
2.5-inch hot-swap HDDs - 6 Gbps NL SAS |
00AJ086 |
A4TU |
1TB 7.2K 6Gbps NL SAS 2.5-inch G3HS HDD |
32 |
00AJ121 |
A4TT |
500GB 7.2K 6Gbps NL SAS 2.5-inch G3HS HDD |
32 |
2.5-inch hot-swap HDDs - 6 Gbps NL SATA |
00AJ136 |
A4TW |
500GB 7.2K 6Gbps NL SATA 2.5-inch G3HS HDD |
32 |
00AJ141 |
A4TX |
1TB 7.2K 6Gbps NL SATA 2.5-inch G3HS HDD |
32 |
2.5-inch hot-swap SSDs - 6 Gbps SAS - Enterprise |
00AJ217 |
A4UC |
800GB SAS 2.5-inch MLC G3HS Enterprise SSD |
32 |
2.5-inch hot-swap SSDs - 6 Gbps SATA SSDs - Enterprise |
00AJ161 |
A4U4 |
S3700 400GB SATA 2.5-inch MLC G3HS Enterprise SSD |
32 |
2.5-inch hot-swap SSDs - 6 Gbps SATA - Enterprise Value |
00AJ405 |
A579 |
480GB SATA 2.5-inch MLC G3HS Enterprise Value SSD |
32 |
2.5-inch hot-swap SSDs - 6 Gbps SATA - Entry |
00FN347 |
AS0J |
960GB SATA 2.5-inch MLC G3HS Entry SSD |
32 |
Internal backup units
The server supports the internal backup unit options that are listed in the following table.
Table 12. Internal tape drives
Part
number |
Feature
code |
Description |
Maximum
supported |
Drives |
- |
A2U7 |
RDX 3 Internal USB Drive |
1 |
00D2786 |
A2VE |
RDX Internal USB 3.0 Dock with 320 GB Cartridge (includes USB cable) |
1 |
00D2787 |
A2VF |
RDX Internal USB 3.0 Dock with 500 GB Cartridge (includes USB cable) |
1 |
00D2788 |
A2VG |
RDX Internal USB 3.0 Dock with 1 TB Cartridge (includes USB cable) |
1 |
49Y9898 |
5345 |
Half High LTO Gen 5 Internal SAS Tape Drive* |
2 |
00D8924 |
A3S3 |
Half High LTO Ultrium Gen 6 Internal SAS Tape Drive* |
2 |
Media |
46W6589 |
A3S6 |
LTO Ultrium Gen 6 Single Media (2.6 TB native capacity) |
|
46C5367 |
5708 |
RDX 320GB Cartridge |
|
46C5368 |
5709 |
RDX 500GB Cartridge |
|
81Y3647 |
A1VL |
RDX 1TB Cartridge |
|
* Supported with the N2215 SAS/SATA HBA; also requires 12Gb SAS Cable for LTO Tape drive, SBB 00MV226, feature code ASTU
USB devices are attached to the internal USB connector. For option part number orders, the USB cable is included with the RDX drive. For CTO, use feature code 9266.
For more information, see the list of Product Guide, RDX USB 3.0 Disk Backup Solution, which is available at this website:
http://lenovopress.com/tips0894
Optical drives
The server supports the optical drive options that are listed in the following table.
Table 13. Optical drives
Part number |
Feature
code |
Description |
Maximum
supported |
Standard models
where used |
None* |
4154 |
Half-High SATA DVD-ROM |
2 |
All standard models |
81Y6404 |
4155 |
Half-High SATA Multiburner |
2 |
- |
* This option is available via CTO only or is already installed in standard models.
The two half-high drives in the table can be installed in any open 5.25-inch drive bay.
The Half-High SATA DVD-ROM drive supports the following media and speeds for reading:
- CD-ROM 48X
- CD-DA (DAE) 40X
- CD-R 48X
- CD-RW 40X
- DVD-ROM (single layer) 16X
- DVD-ROM (dual layer) 12X
- DVD-R (4.7 GB) 16X
- DVD-R DL 12X
- DVD+R 16X
- DVD+R DL 12X
- DVD-RW (4.7 GB) 12X
- DVD+RW 12X
- DVD-RAM (4.7/9.4 GB) 6X
The Half-High SATA multiburner drive supports the same media and speeds for reading as HH DVD-ROM. In addition, this drive supports the following media and speeds for writing:
- CD-R 24X
- CD-RW 4X
- High Speed CD-RW 10X
- Ultra Speed CD-RW 16X
- DVD-R 8X
- DVD-R DL 8X
- DVD+R 8X
- DVD+R DL 8X
- DVD-RW 6X
- DVD+RW 8X
- DVD-RAM 3X
I/O expansion options
The server supports up to seven PCIe 3.0 slots: Four slots (1 - 4) when one CPU is installed or seven slots when two CPUs are installed. The following slot form factors are available:
- Slot 1: PCIe 3.0 x8 (x8 wired); full-height, half-length
- Slot 2: PCIe 3.0 x16 (x8 wired); full-height, full-length
- Slot 3: PCIe 3.0 x16 (x16 wired); full-height, full-length
- Slot 4: PCIe 3.0 x8 (x8 wired); full-height, full-length
- Slot 5: PCIe 3.0 x8 (x8 wired); full-height, half-length (requires second processor)
- Slot 6: PCIe 3.0 x16 (x16 wired); full-height, full-length (requires second processor)
- Slot 7: PCIe 3.0 x16 (x16 wired) full-height, full-length (requires second processor)
Slots 3 and 6 support double-wide GPUs
The COM Port Bracket, part number 00KC332, is used for making an external serial port available at the rear of the server. This option includes the bracket and the cable. The COM Port option is mounted in one of the PCIe slots and that PCIe slot cannot be used. The following table lists the PCIe slot options.
Table 14. System x3500 M5 COM Port Kit ordering information
Part number |
Feature
code |
Description |
Maximum
supported |
00KC332 |
ARZ0 |
System x3500 M5 COM Port Kit |
1 |
Network adapters
The x3550 M5 supports four integrated Gigabit Ethernet ports with the following features:
- A Broadcom BCM5719 chip
- Four Gigabit Ethernet ports
- NIC Teaming (load balancing and failover)
- Ethernet features:
- Compliant with 1 Gb Ethernet IEEE 802.3, 802.3u, and 802.3ab PHY specifications
- Integrated PHY for 10/100/1000 Mbps for multispeed, full, and half-duplex auto-negotiation
- Automatic MDI crossover
- IEEE 802.3x-compliant flow control support
- IEEE 1588 protocol and 802.1AS time synchronization implementation
- IEEE802.3az - Energy Efficient Ethernet (EEE)
- I/O Virtualization features:
- I/O Virtualization support for VMware NetQueue and Microsoft virtual machine queue (VMQ)
- Function Level Reset (FLR)
- IEEE 802.1q Virtual Local Area Network (VLAN) tagging support
- Stateless offload and performance features:
- TCP, IP, and User Datagram Protocol (UDP) checksum offload
- TCP segmentation offload (TCO)
- Large Send Offload (LSO)
- Receive Side Scaling (RSS) and Transmit Side Scaling (TSS)
- Message Signal Interrupt (MSI) and Message Signal Interrupt Extension (MSI-X) support
- Support for jumbo frames up to 9600 bytes
The following table lists other supported network adapters.
Table 15. Network adapters
Part number |
Feature
code |
Description |
Maximum
supported
(1 CPU / 2 CPUs) |
40 Gb Ethernet |
00D9550 |
A3PN |
Mellanox ConnectX-3 40GbE / FDR IB VPI Adapter* |
4 / 7 |
10 Gb Ethernet |
44T1370 |
A5GZ |
Broadcom NetXtreme 2x10GbE BaseT Adapter |
4 / 7 |
94Y5180 |
A4Z6 |
Broadcom NetXtreme Dual Port 10GbE SFP+ Adapter* |
4 / 7 |
00JY830 |
A5UU |
Emulex VFA5 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW* |
4 / 7 |
None |
AS3M |
Emulex VFA5 2x10 GbE SFP+ Integrated Adapter* |
1 / 1 |
00JY820 |
A5UT |
Emulex VFA5 2x10 GbE SFP+ PCIe Adapter* |
4 / 7 |
00JY824 |
A5UV |
Emulex VFA5 FCoE/iSCSI SW for PCIe Adapter for System x (FoD)
(Features on Demand upgrade for 00JY820 and feature code AS3M) |
4 / 7 |
49Y7960 |
A2EC |
Intel X520 Dual Port 10GbE SFP+ Adapter* |
4 / 7 |
49Y7970 |
A2ED |
Intel X540-T2 Dual Port 10GBaseT Adapter |
4 / 7 |
81Y3520 |
AS73 |
Intel X710 2x10GbE SFP+ Adapter* |
4 / 7 |
00D9690 |
A3PM |
Mellanox ConnectX-3 10 GbE Adapter* |
4 / 7 |
90Y4600 |
A3MR |
QLogic 8200 Dual Port 10GbE SFP+ VFA* |
4 / 7 |
00Y5624 |
A3MT |
QLogic 8200 VFA FCoE/iSCSI License for System x (FoD)
(Features on Demand upgrade for 90Y4600) |
4 / 7 |
47C9977 |
A522 |
Solarflare SFN7122F 2x10GbE SFP+ Flareon Ultra* |
4 / 7 |
1 Gb Ethernet |
42C1780 |
2995 |
Broadcom NetXtreme 2xGbE BaseT Adapter |
4 / 7 |
90Y9370 |
A2V4 |
Broadcom NetXtreme I Dual Port GbE Adapter |
4 / 7 |
90Y9352 |
A2V3 |
Broadcom NetXtreme I Quad Port GbE Adapter |
4 / 7 |
49Y4230 |
5767 |
Intel Ethernet Dual Port Server Adapter I340-T2 |
4 / 7 |
49Y4240 |
5768 |
Intel Ethernet Quad Port Server Adapter I340-T4 |
4 / 7 |
00AG510 |
A56L |
Intel I350-T2 2xGbE BaseT Adapter |
4 / 7 |
00AG520 |
A56M |
Intel I350-T4 4xGbE BaseT Adapter |
4 / 7 |
* Require SFP+ optical transceivers or DAC cables that must be purchased separately.
For more information, see the list of Lenovo Press Product Guides in the Networking adapters category at:
http://lenovopress.com/systemx/networkadapters
Storage host bus adapters
The following table lists storage HBAs that are supported by the x3500 M5 server.
Table 16. Storage adapters
Part number |
Feature
code |
Description |
Maximum
supported
(1 CPU / 2 CPUs) |
16 Gb Fibre Channel |
81Y1668 |
A2XU |
Brocade 16Gb FC Single-port HBA for System x |
4 / 7 |
81Y1662 |
A2W6 |
Emulex 16Gb FC Dual-port HBA for System x |
4 / 7 |
81Y1655 |
A2W5 |
Emulex 16Gb FC Single-port HBA for System x |
4 / 7 |
00Y3341 |
A3KX |
QLogic 16Gb FC Dual-port HBA for System x |
4 / 7 |
00Y3337 |
A3KW |
QLogic 16Gb FC Single-port HBA for System x |
4 / 7 |
8 Gb Fibre Channel |
46M6050 |
3591 |
Brocade 8Gb FC Dual-port HBA for System x |
4 / 7 |
46M6049 |
3589 |
Brocade 8Gb FC Single-port HBA for System x |
4 / 7 |
42D0494 |
3581 |
Emulex 8Gb FC Dual-port HBA for System x |
4 / 7 |
42D0485 |
3580 |
Emulex 8Gb FC Single-port HBA for System x |
4 / 7 |
42D0510 |
3579 |
QLogic 8Gb FC Dual-port HBA for System x |
4 / 7 |
42D0501 |
3578 |
QLogic 8Gb FC Single-port HBA for System x |
4 / 7 |
SAS |
46M0907 |
5982 |
6 Gb SAS HBA Controller |
4 / 7 |
00AE912 |
A5M0 |
N2225 SAS/SATA HBA for System x |
4 / 7 |
00AE916 |
A5M1 |
N2226 SAS/SATA HBA for System x |
4 / 7 |
For more information, see the list of Lenovo Press Product Guides in the Host bus adapters category at this website:
http://lenovopress.com/systemx/hba
PCIe SSD adapters
The server currently does not support High IOPS SSD adapters.
GPU adapters
The x3500 M5 server supports graphics processing units (GPUs) that are listed in the following table. Up to two GPUs are supported, depending on the number of processors that are installed in a server.
Table 17. GPU adapters
Part number |
Feature code |
Description |
Maximum supported
(1 CPU / 2 CPUs) |
00FP672 |
A3YV |
NVIDIA Quadro K6000 |
1 / 2 |
The following other rules apply:
- If two GPUs are installed, they must be identical
- The first GPU is installed in slot 3; the second GPU is installed in slot 6 and requires the second processor to be installed.
- The number of GPUs that can be installed depends on the type of power supply that is installed and the type and number of other components that are installed. For more information,see the Power Supply section.
- If a NVIDIA card is installed, the maximum memory that can be installed is 1 TB.
Power supplies and redundant cooling
The server supports up to two redundant power supplies. Standard models come with one or two power supplies (depending on the model).
The server also comes standard with two (for models with one processor installed) or four (for models with two processors installed) hot-swap cooling fans. For models with only one processor, an optional Redundant Cooling Kit provides N+1 cooling redundancy. The following table lists the power supplies and redundant cooling upgrade options.
Table 18. Power supplies
Part number |
Feature code |
Description |
Maximum
supported |
Standard models
where used |
00AL533 |
A5MY |
System x 550W High Effiency Platinum AC Power Supply |
2 |
A2x, B2x, C2x, C3x, C4x, D2x |
00AL534 |
A5MZ |
System x 750W High Efficiency Platinum AC Power Supply |
2 |
G2x, G3x |
00AL536 |
A5N0 |
System x 900W High Efficency Platinum AC Power Supply |
2 |
H2x, J2x |
00AL535 |
A5N1 |
System x 750W High Efficiency Titanium AC Power Supply |
2 |
- |
None* |
A5CH |
System x 550W High Efficency Platinum AC Fixed Power Supply |
1 |
- |
00AL537 |
A5D6 |
System x3500 M5 Redundant Cooling Kit |
1 |
- |
* CTO only
The following table shows the combinations supported.
Table 19. Supported configurations
Power supply |
550 W (A) |
550 W (B) |
750 W (A) |
750 W (B) |
900 W (1A) |
900 W (2A) |
900 W (2B) |
900 W (2C) |
900 W (2D) |
900 W (2E) |
Maximum processors |
1 |
2, max 90W |
1 |
2 |
1 |
2 |
2 |
2 |
2, max 135W |
2, max 90W |
Memory maximums (mutually exclusive) |
|
No limit |
No limit |
No limit |
No limit |
No limit |
No limit |
No limit |
No limit |
No limit |
12 |
|
0 |
0 |
0 |
0 |
0 |
12 |
0 |
No limit |
0 |
0 |
Drive maximums (mutually exclusive) |
|
No limit |
6 |
No limit |
No limit |
No limit |
No limit |
6 |
6 |
No limit |
6 |
|
16 |
8 |
16 |
16 |
No limit |
24 |
8 |
8 |
No limit |
8 |
Intermix 3.5-in and 2.5-in drives
|
6x 3.5 + 8x 2.5 |
No |
6x 3.5 + 8x 2.5 |
6x 3.5 + 8x 2.5 |
No limit |
No limit |
0 |
0 |
No limit |
0 |
PCIe adapters (non-GPU)* |
No limit |
No limit |
No limit |
No limit |
No limit |
No limit |
No limit |
No limit |
No limit |
2 |
Maximum GPUs |
0 |
0 |
1 |
0 |
1 |
0 |
1 |
0 |
0 |
2 |
* GPUs use two PCIe slots; therefore, if a GPU is installed, the number of non-GPU adapters that are installed is reduced by two.
AC power supply options ships without a line cord, it must be purchased separately. Country-specific line cords and rack cables can be ordered if needed, as listed in the following table.
Table 20. Power cables
Part number |
Feature code |
Description |
Rack power cables |
39Y7932 |
6263 |
4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable |
39Y7937 |
6201 |
1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable |
39Y7938 |
6204 |
IEC309 C20 to C13 rack jumper cable |
Country-specific power cords |
39Y7917 |
6212 |
European 10A line C13 to CEE 7/7 (2.8M) |
39Y7918 |
6213 |
Denmark 10A line C13 to DK2-5A (2.8M) |
39Y7919 |
6216 |
Switzerland 10A line C13 to SEV 1011 (2.8M) |
39Y7920 |
6218 |
Israel 10A line C13 to SI 32 (2.8M) |
39Y7921 |
6217 |
Italy 10A line C13 to CEE 7/7 (2.8M) |
39Y7922 |
6214 |
South Africa 10A line C13 to SABS 164/1 (2.8M) |
39Y7923 |
6215 |
United Kingdom 10A line C13 to BS 1363 (2.8M) |
39Y7924 |
6211 |
Australia/NZ 10A line C13 to SAA-AS C112 (2.8M) |
39Y7925 |
6219 |
Korea 7A line C13 to KETI 15A/250V (2.8M) |
39Y7927 |
6269 |
India 6A line C13 to Fig 68 (2.8M) |
39Y7928 |
6210 |
China 6A line C13 to GB 2099.1 (2.8M) |
39Y7929 |
6223 |
Brazil 10A line C13 to NBR 6147 (2.8M) |
39Y7930 |
6222 |
Argentina 10A line C13 to IRAM 2063 (2.8M) |
39Y7931 |
6207 |
Power Cable - C13 / NEMA 5-15P 14ft |
00CG265 |
A53E |
Power Cord Taiwan AC plug 10A/250V, 2.8M; OPT |
00CG267 |
A53F |
Power Cord Taiwan AC plug 15A/125V; 2.8M; OPT |
46M2592 |
A1RF |
10A/250V C13 to NEMA 6-15P 2.8m line cord |
46M2593 |
A1RE |
Japan 10A/100V C13 to JIS C-8303 2.8m line cord |
Integrated virtualization
The server supports the VMware vSphere (ESXi) hypervisor on one or two SD cards with the optional SD Media Adapter for System x. This adapter is in a dedicated connector on the system board, as shown in the following figure.
Figure 12. SD Media Adapter with one SD Card installed
When only one SD card is installed in the adapter, you can create up to 16 volumes, each of which is presented to UEFI as a bootable device. When two SD Media cards are inserted, volumes can be mirrored (RAID 1) across both cards, up to a total of eight mirrored volumes. The use of mirrored volumes improves system availability because the server remains operational, even if one SD card fails. The RAID functionality is handled internally by the SD Media Adapter.
The following table shows the available options. The table also indicates whether the option includes the SD Media RAID Adapter and how many SD cards are included.
Table 21. Virtualization options
Part number |
Feature
code |
Description |
Includes
Adapter |
SD Cards
Included |
00ML706 |
A5TJ |
SD Media Adapter for Systems x
(Option 00ML706 includes 2 blank 32GB SD cards) |
Yes |
2* |
00ML700 |
AS2V |
Blank 32GB SD Media for System x |
No |
2 |
None** |
AS4B |
RAID Adapter for SD Media w/ VMware ESXi 5.1 U2 (2 SD Media, RAIDed) |
Yes |
2 |
None** |
ASCG |
RAID Adapter for SD Media w/ VMware ESXi 5.1 U2 (1 SD Media) |
Yes |
1 |
* Option 00ML706 includes two 32GB SD cards; however, for CTO orders, feature code A5TJ does not include SD media and the 32GB cards and VMware vSphere preload must be selected separately.
** CTO only.
Systems management
The server contains IMM2.1, which provides advanced service-processor control, monitoring, and an alerting function. If an environmental condition exceeds a threshold or if a system component fails, the IMM2.1 lights LEDs to help you diagnose the problem, records the error in the event log, and alerts you to the problem. Optionally, the IMM2.1 also provides a virtual presence capability for remote server management capabilities.
The IMM provides remote server management through the following industry-standard interfaces:
- Intelligent Platform Management Interface (IPMI) Version 2.0
- Simple Network Management Protocol (SNMP) Version 3
- Common Information Model (CIM)
- Web browser
The optional Integrated Management Module Advanced Upgrade is required for enabling remote presence and blue-screen capture features. The remote presence feature provides the following functions:
- Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel colors, regardless of the system state
- Remotely accessing the server by using the keyboard and mouse from a remote client
- Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote client, and mapping ISO and diskette image files as virtual drives that are available for use by the server
- Uploading a diskette image to the IMM memory and mapping it to the server as a virtual drive
The blue-screen capture feature captures the video display contents before the IMM restarts the server when the IMM detects an operating-system hang condition. A system administrator can use the blue-screen capture to assist in determining the cause of the hang condition. The following table lists the remote management option.
Table 22. Remote management option
Part number |
Feature code |
Description |
Maximum
supported |
90Y3901 |
A1ML |
Integrated Management Module Advanced Upgrade |
1 |
All standard models include basic light path diagnostics, which include system LEDs on the front of the server (see the following figure) and LEDs near the monitored components (for example, the DIMM error LED on the system board). The server also offers an optional upgrade to supply another array of light path diagnostic LEDs on the front of the chassis.
The following table lists the ordering information for the light path diagnostics panel upgrade kit.
Table 23. Remote management option
Part number |
Feature code |
Description |
Maximum
supported |
00AL566 |
A5N3 |
System x3500 M5 Lightpath Upgrade Kit |
1 |
The following figure shows the meaning of each LED.
Figure 13. System LEDs and the optional light path diagnostics panel
Note: The light path diagnostics panel upgrade kit supplies the array of LEDs that is mounted in a bracket that is installed inside the server, as shown in the following figure. The light path diagnostics indicators are still visible on the front of the server, even if the upgrade kit is not installed.
Figure 14. System x3500 M5 Lightpath Upgrade Kit
IBM Security Key Lifecycle Manager for System x SEDs - FoD (SKLM - FoD) is an optional feature, which is available in System x environments that centralizes, simplifies, and automates the data encryption key management process to help minimize risk and reduce operational costs. SKLM - FoD offers a simple and robust solution for key storage, key serving, and key lifecycle management for self-encrypting drives (SEDs) in local and distributed System x environments. The FoD upgrade can be configured with the ServeRAID M5210 and M1215 RAID controllers paired with SEDs. The following table lists SKLM-FoD part numbers.
Table 24. Security Key Lifecycle Manager - FoD part numbers
Part number |
Feature code |
Description |
Maximum supported |
United States, Canada, Asia Pacific and Japan |
00D9998 |
A5U1 |
IBM SKLM for System x w/SEDs - FoD per Install w/1Yr S&S |
1 |
00D9999 |
AS6C |
IBM SKLM for System x w/SEDs - FoD per Install w/3Yr S&S |
1 |
Latin America, Europe, Middle East and Africa |
00FP648 |
A5U1 |
IBM SKLM for System x w/SEDs - FoD per Install w/1Yr S&S |
1 |
00FP649 |
AS6C |
IBM SKLM for System x w/SEDs - FoD per Install w/3Yr S&S |
1 |
Supported operating systems
The server supports the following operating systems:
- Microsoft Windows Server 2012 R2
- Microsoft Windows Server 2008 R2
- Microsoft Windows Server 2012
- SUSE LINUX Enterprise Server 11 for AMD64/EM64T
- SUSE LINUX Enterprise Server 11 with Xen for AMD64/EM64T
- Red Hat Enterprise Linux 6 Server x64 Edition
- Red Hat Enterprise Linux 7
- SUSE Enterprise Linux Server (SLES) 12
- SUSE Linux Enterprise Server 12 with XEN
- VMware vSphere 5.5 (ESXi)
- VMware vSphere 5.1 (ESXi)
Some operating systems might have support delayed until 60 or 90 days after general availability. For more information about the supported specific versions and service levels and any other prerequisites. see the following ServerProven® website :
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml
Physical and electrical specifications
The server features the following dimensions and weight (approximate):
- Tower:
- Width: 218 mm (8.6 in)
- Depth: 720 mm (28.3 in)
- Height: 440 mm (17.25 in)
- Weight fully configured: 45.5 kg (100.3 lb)
- Weight minimum configuration: 30.8 kg (67.9 lb)
- With rack conversion kit:
- Width: 423 mm (16.6 in)
- Depth: 706 mm (27.8 in)
- Height: 218 mm (8.6 in )
- Weight fully configured: 44.2 kg (97.4 lb)
- Weight minimum configuration: 29.5 kg (65 lb) minimum configuration
The server features the following supported environment:
- Design to ASHRAE Class A3, ambient of 36 °C to 40 °C (96.8 °F to 104 °F), with relaxed support:
- Supports cloud-like workload with no performance degradation acceptable (Turbo-Off).
- Under no circumstance can any combination of worst-case workload and configuration result in system shutdown or design exposure at 40 °C.
- The worst-case workload (like Linpack, Turbo-On) might have performance degradation.
- Air temperature:
- Server on: 5 - 40 °C (41 to 104 °F); altitude: 0 - 950 m (3,100 ft)
- Server on: 5 - 28 °C (41 - 82 °F); altitude: 915 m (3,000 ft) - 3050 m (10,000 ft)
- Server off (with standby power): 5 - 45 °C (41 - 113 °F)
- Storage: 1 - 60 °C (34 - 140 °F)
- Shipping: -40 - 60 °C (-40 - 140 °F)
- Humidity: 8 - 85%, Max. Dew Point 24 °C
- Electrical:
- Models with 900 W AC power supplies:
- 100 - 127 (nominal) V ac; 50 Hz or 60 Hz; 10.3 A
- 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 5.0 A
- Input kilovolt-amperes (kVA) (approximately):
- Minimum configuration: 0.15 kVA
- Maximum configuration: 1.194 kVA
- Models with 750 W Platinum AC power supplies:
- 100 - 127 (nominal) V ac; 50 Hz or 60 Hz; 8.6 A
- 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 4.2 A
- Input kilovolt-amperes (kVA) (approximately):
- Minimum configuration: 0.15 kVA
- Maximum configuration: 1.015 kVA
- Models with 750 W Titanium AC power supplies:
- 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 4.2 A
- Input kilovolt-amperes (kVA) (approximately):
- Minimum configuration: 0.15 kVA
- Maximum configuration: 0.965 kVA
- Models with 550 W AC power supplies:
- 100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 6.5 A
- 200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 3.3 A
- Input kilovolt-amperes (kVA) (approximately):
- Minimum configuration: 0.16 kVA
- Maximum configuration: 0.732 kVA
- BTU output:
- Base configuration: 2931 Btu/hr (859 watts)
- Maximum configuration: 4043 Btu/hr (1185 watts)
- Acoustical noise emissions:
- Sound power, idling: 6.0 bels
- Sound power, operating: 6.0 bels
Warranty options
The Lenovo System x3500 M5 has a three-year warranty with 24x7 standard call center support and 9x5 Next Business Day onsite coverage. Also available are Lenovo Services warranty maintenance upgrades and post-warranty maintenance agreements, with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.
Lenovo warranty service upgrade offerings are country-specific. Not all warranty service upgrades are available in every country. For more information about Lenovo warranty service upgrade offerings that are available in your country, visit the Lenovo Services website:
https://www-304.ibm.com/sales/gss/download/spst/servicepac/extProductSelectorWWW.do
The following table explains warranty service definitions in more detail.
Table 25. Warranty service definitions
Term |
Description |
On-site service |
A service technician will arrive at the client’s location for equipment service. |
24x7x2 hour |
A service technician is scheduled to arrive at the client’s location within two hours after remote problem determination is completed. Lenovo provides service around the clock, every day, including Lenovo holidays. |
24x7x4 hour |
A service technician is scheduled to arrive at the client’s location within four hours after remote problem determination is completed. Lenovo provides service around the clock, every day, including Lenovo holidays. |
9x5x4 hour |
A service technician is scheduled to arrive at the client’s location within four business hours after remote problem determination is completed. Lenovo provides service 8:00 am - 5:00 pm in the client's local time zone, Monday-Friday, excluding Lenovo holidays. For example, if a customer reports an incident at 3:00 pm on Friday, the technician will arrive by 10:00 am the following Monday. |
9x5 next business day |
A service technician is scheduled to arrive at the client’s location on the business day after remote problem determination is completed. Lenovo provides service 8:00 am - 5:00 pm in the client's local time zone, Monday - Friday, excluding Lenovo holidays. Calls received after 4:00 pm local time require an extra business day for service dispatch. Next business day service is not guaranteed. |
Committed Repair |
Problems receive priority handling so that repairs are completed within the committed time of 6, 8, or 24 hours. Lenovo provides service 24 hours/day, every day, including Lenovo holidays. |
The following Lenovo warranty service upgrades are available:
- Warranty and maintenance service upgrades:
- Three, four, or five years of 9x5 or 24x7 service coverage
- Onsite response from next business day to 2 or 4 hours
- Committed repair service
- Warranty extension of up to 5 years
- Post warranty extensions
- Committed Repair Service
Committed Repair Services enhances the level of Warranty Service Upgrade or Post Warranty/Maintenance Service offering associated with the selected systems. Offerings vary and are available in select countries.
- Priority handling to meet defined time frames to restore the failing machine to good working condition
- Committed repair service levels are measured within the following coverage hours:
- 24x7x6: Service performed 24 hours per day, 7 days per week, within 6 hours
- 24x7x8: Service performed 24 hours per day, 7 days per week, within 8 hours
- 24x7x24: Service performed 24 hours per day, 7 days per week, within 24 hours
- Hard Drive Retention
Lenovo’s Hard Drive Retention service is a multi-drive hard drive retention offering that ensures your data is always under your control, regardless of the number of hard drives that are installed in your Lenovo server. In the unlikely event of a hard drive failure, you retain possession of your hard drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The Hard Drive Retention service can be purchased in convenient bundles with our warranty upgrades and extensions.
- Microcode Support
Keeping microcode current helps prevent hardware failures and security exposure. There are two levels of service: analysis of the installed base and analysis and update where required. Offerings vary by country and can be bundled with other warranty upgrades and extensions.
- Remote Technical Support Services (RTS)
RTS provides comprehensive technical call center support for covered servers, storage, operating systems, and applications. Providing a single source for support of hardware and software issues, RTS can reduce problem resolution time, decreasing the cost to address technical problems and increasing uptime. Offerings are available for Windows, Linux, IBM Systems Director, VMware, Microsoft business applications, and Lenovo System x storage devices, and IBM OEM storage devices.
Regulatory compliance
The server conforms to the following standards:
- FCC - Verified to comply with Part 15 of the FCC Rules, Class A
- Canada ICES-003, issue 5, Class A
- UL/IEC 60950-1
- CSA C22.2 No. 60950-1-07
- NOM-019
- Argentina IEC60950-1
- Japan VCCI, Class A
- IEC-60950-1 (CB Certificate and CB Test Report)
- Australia/New Zealand AS/NZS CISPR 22:2006, Class A; AS/NZS 60950.1
- Taiwan BSMI CNS13438, Class A ;CNS14336-1
- GB9254 Class A, GB17625.1
- China CCC GB4943.1
- Korea KN22, Class A; KN24
External disk storage expansion
The server supports attachment to external storage expansion enclosures, such as the EXP2500 series, by using the ServeRAID M5225 SAS/SATA Controller. The server can also be attached to supported external storage systems by using a supported HBA. For more information, see the following table.
Table 26. RAID controllers and options for external disk storage expansion
Part number |
Feature code |
Description |
Maximum supported |
Standard models where used |
12 Gb RAID controllers |
00AE938 |
A5ND |
ServeRAID M5225-2GB SAS/SATA Controller |
4 |
- |
Feature on Demand (FoD) upgrades for the M5225 |
47C8706 |
A3Z5 |
ServeRAID M5200 Series RAID 6 Upgrade |
1* |
- |
47C8710 |
A3Z7 |
ServeRAID M5200 Series Performance Accelerator |
1* |
- |
47C8712 |
A3Z8 |
ServeRAID M5200 Series SSD Caching Enabler |
1* |
- |
* One FoD upgrade for the M5225 activates the feature on all M5225 controllers that are installed in a server.
The ServeRAID M5225 SAS/SATA Controller has the following specifications:
- Eight external 12 Gbps SAS/SATA ports
- Supports 12, 6, and 3 Gb/s SAS and 6 and 3 Gb/s SATA data transfer rates
- Two external x4 mini-SAS HD connectors (SFF-8644)
- Supports 2 GB flash-backed cache (standard)
- Supports RAID levels 0, 1, 5, 10, and 50 (standard)
- Supports RAID 6 and 60 with the optional M5200 Series RAID 6 Upgrade
- Supports optional M5200 Series Performance Accelerator and SSD Caching upgrades
- PCIe x8 Gen 3 host interface
- Based on the LSI SAS3108 12 Gbps ROC controller
- Supports connectivity to the EXP2512 and EXP2524 storage expansion enclosures
For more information about the ServeRAID M5225, see the Lenovo Press Product Guide at http://lenovopress.com/tips1258
The ServeRAID M5225 SAS/SATA Controller supports connectivity to external expansion enclosures that are listed in the following table. Up to nine expansion enclosures can be daisy-chained per one M5225 external port. For better performance, distribute expansion enclosures evenly across both M5225 ports.
Table 27. External expansion enclosures
Part number |
Description |
Maximum quantity supported per one M5225 |
70F0 / 70F1 |
Lenovo ThinkServer SA120 |
8 |
610012X |
EXP2512 Storage Enclosure |
17 |
610024X |
EXP2524 Storage Enclosure |
9 |
Lenovo ThinkServer SA120 support
For details about supported drives and cables for the Lenovo ThinkServer SA120, see the Lenovo Press Product Guide:
http://lenovopress.com/tips1234
EXP2512 and EXP2524 support
The external SAS cables that are listed in the following table support connectivity between external expansion enclosures and the ServeRAID M5225 SAS/SATA Controller.
Table 28. External SAS cables for external storage expansion enclosures
Part number |
Description |
Maximum quantity supported per one enclosure |
Server to Expansion enclosure connectivity (Mini-SAS HD x4 to Mini-SAS x4) |
00MJ162 |
0.6m SAS Cable (mSAS HD to mSAS) |
1 |
00MJ163 |
1.5m SAS Cable (mSAS HD to mSAS) |
1 |
00MJ166 |
3m SAS Cable (mSAS HD to mSAS) |
1 |
Expansion enclosure to Expansion enclosure connectivity (Mini-SAS x4 to Mini-SAS x4) |
39R6529 |
1 m SAS Cable |
1 |
39R6531 |
3 m SAS Cable |
1 |
The following table lists drives that are supported by EXP2512 external expansion enclosures.
Table 29. Drive options for EXP2512 external expansion enclosures
Part number |
Description |
Maximum quantity supported per one enclosure |
3.5-inch NL SAS HS HDDs |
00NC555 |
2TB 7,200 rpm 6Gb SAS NL 3.5-inch HDD |
12 |
00NC557 |
3TB 7,200 rpm 6Gb SAS NL 3.5-inch HDD |
12 |
00NC559 |
4TB 7,200 rpm 6Gb SAS NL 3.5-inch HDD |
12 |
The following table lists HDDs that are supported by EXP2524 external expansion enclosures.
Table 30. Drive options for EXP2524 external expansion enclosures
Part number |
Description |
Maximum quantity supported per one enclosure |
2.5-inch NL SAS HS HDDs |
00NC571 |
1TB 7,200 rpm 6Gb SAS NL 2.5-inch HDD |
24 |
2.5-inch SAS HS HDDs |
00NC561 |
146GB 15,000 rpm 6Gb SAS 2.5-inch HDD |
24 |
00NC563 |
300GB 15,000 rpm 6Gb SAS 2.5-inch HDD |
24 |
00NC565 |
600GB 10,000 rpm 6Gb SAS 2.5-inch HDD |
24 |
00NC567 |
900GB 10,000 rpm 6Gb SAS 2.5-inch HDD |
24 |
00NC569 |
1.2TB 10,000 rpm 6Gb SAS 2.5-inch HDD |
24 |
2.5-inch SAS HS SSDs |
00NC573 |
200GB 6Gb SAS 2.5-inch SSD |
24 |
00NC575 |
400GB 6Gb SAS 2.5-inch SSD |
24 |
External disk storage systems
The following table lists the external storage systems that are supported by the server and can be ordered through the System x sales channel.
Table 31. External disk storage systems
Part number |
Description |
2071CU2 |
IBM Storwize V3500 LFF Dual Control Enclosure |
2071CU3 |
IBM Storwize V3500 SFF Dual Control Enclosure |
6099L2C |
IBM Storwize V3700 3.5-inch Storage Controller Unit |
6099S2C |
IBM Storwize V3700 2.5-inch Storage Controller Unit |
6099T2C |
IBM Storwize V3700 2.5-inch DC Storage Controller Unit |
6194L2C |
IBM Storwize V5000 LFF Control Enclosure |
6194LEU |
IBM Storwize V5000 LFF Expansion Enclosure |
6194S2C |
IBM Storwize V5000 SFF Control Enclosure |
6194SEU |
IBM Storwize V5000 SFF Expansion Enclosure |
6195SC5 |
IBM Storwize V7000 2.5-inch Storage Controller Unit |
6195LEF |
IBM Storwize V7000 3.5-inch Storage Expansion Unit |
6195SEF |
IBM Storwize V7000 2.5-inch Storage Expansion Unit |
For more information, see the list of Product Guides in the System Storage category at this website:
http://lenovopress.com/systemx/externalstorage
External backup units
The server supports the external backup attachment options that are listed in the following table.
Table 32. External backup options
Part number |
Description |
External tape expansion enclosures for internal tape drives |
87651UX |
1U Tape Drive Enclosure |
87651NX |
1U Tape Drive Enclosure (with Nema 5-15P LineCord) |
Tape enclosure adapters (with cables) |
44E8869 |
USB Enclosure Adapter Kit |
40K2599 |
SAS Enclosure Adapter Kit |
Internal backup drives supported by external tape enclosures |
00D2786 |
RDX Internal USB 3.0 Dock with 320GB Cartridge |
00D2787 |
RDX Internal USB 3.0 Dock with 500GB Cartridge |
00D2788 |
RDX Internal USB 3.0 Dock with 1TB Cartridge |
49Y9898 |
Half High LTO Gen 5 Internal SAS Tape Drive |
00D8924 |
Half High LTO Ultrium Gen 6 Internal SAS Tape Drive |
External backup units* |
362532Y |
RDX External USB 3.0 Dock with 320GB Cartridge |
362550Y |
RDX External USB 3.0 Dock with 500GB Cartridge |
36251TY |
RDX External USB 3.0 Dock with 1TB Cartridge |
3628L5X |
Half High LTO Gen 5 External SAS Tape Drive (with US line cord) |
3628N5X |
Half High LTO Gen 5 External SAS Tape Drive (without line cord) |
* These external tape drives can be ordered through the System x sales channel. The server might support other tape drives that are not listed in this table. For more information, see the IBM System Storage Interoperation Center (SSIC) at this website:
http://www.ibm.com/systems/support/storage/ssic
For more information, see the list of Lenovo Press Product Guides in the Backup units category at this website:
http://lenovopress.com/systemx/tape
Top-of-rack Ethernet switches
The server supports the top-of-rack Ethernet switches that are listed in the following table.
Table 33. Top-of-rack switches
Part number |
Description |
1 Gb top-of-rack switches |
7159BAX |
Lenovo RackSwitch G7028 (Rear to Front) |
7159CAX |
Lenovo RackSwitch G7052 (Rear to Front) |
715952F |
Lenovo RackSwitch G8052 (Front to Rear) |
7159G52 |
Lenovo RackSwitch G8052 (Rear to Front) |
10 Gb top-of-rack switches |
7159BF7 |
Lenovo RackSwitch G8124E (Front to Rear) |
7159BR6 |
Lenovo RackSwitch G8124E (Rear to Front) |
715964F |
Lenovo RackSwitch G8264 (Front to Rear) |
7159G64 |
Lenovo RackSwitch G8264 (Rear to Front) |
7159DFX |
Lenovo RackSwitch G8264CS (Front to Rear) |
7159DRX |
Lenovo RackSwitch G8264CS (Rear to Front) |
7159CFV |
Lenovo RackSwitch G8272 (Front to Rear) |
7159CRW |
Lenovo RackSwitch G8272 (Rear to Front) |
7159GR5 |
Lenovo RackSwitch G8296 (Front to Rear) |
7159GR6 |
Lenovo RackSwitch G8296 (Rear to Front) |
40 Gb top-of-rack switches |
7159BFX |
Lenovo RackSwitch G8332 (Front to Rear) |
7159BRX |
Lenovo RackSwitch G8332 (Rear to Front) |
For more information, see the list of Lenovo Press Product Guides in the Top-of-rack switches category at this website:
http://lenovopress.com/systemx/tor
Uninterruptible power supply units
The server supports attachments to the uninterruptible power supply (UPS) units that are listed in the following table.
Table 34. Uninterruptible power supply units
Part number |
Description |
Tower UPS units |
55951AX |
T1kVA Tower UPS (100-125VAC) |
55951KX |
T1kVA Tower UPS (200-240VAC) |
55952AX |
T1.5kVA Tower UPS (100-125VAC) |
55952KX |
T1.5kVA Tower UPS (200-240VAC) |
53961AX |
1000VA LCD Tower UPS (120V) |
53961JX |
1000VA LCD Tower UPS (100V) |
53961KX |
1000VA LCD Tower UPS (230V) |
53962AX |
1500VA LCD Tower UPS (120V) |
53962JX |
1500VA LCD Tower UPS (100V) |
53962KX |
1500VA LCD Tower UPS (230V) |
Rack-mounted or tower UPS units |
55941AX |
RT1.5kVA 2U Rack or Tower UPS (100-125VAC) |
55941KX |
RT1.5kVA 2U Rack or Tower UPS (200-240VAC) |
55942AX |
RT2.2kVA 2U Rack or Tower UPS (100-125VAC) |
55942KX |
RT2.2kVA 2U Rack or Tower UPS (200-240VAC) |
55943AX |
RT3kVA 2U Rack or Tower UPS (100-125VAC) |
55943KX |
RT3kVA 2U Rack or Tower UPS (200-240VAC) |
55945KX |
RT5kVA 3U Rack or Tower UPS (200-240VAC) |
55946KX |
RT6kVA 3U Rack or Tower UPS (200-240VAC) |
55948KX |
RT8kVA 6U Rack or Tower UPS (200-240VAC) |
55949KX |
RT11kVA 6U Rack or Tower UPS (200-240VAC) |
55948PX |
RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
55949PX |
RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
Rack-mounted UPS units |
53951AX |
1500VA LCD 2U Rack UPS (100V/120V) |
53951KX |
1500VA LCD 2U Rack UPS (230V) |
53952AX |
2200VA LCD 2U Rack UPS (100V/120V) |
53952KX |
2200VA LCD 2U Rack UPS (230V) |
53953AX |
3000VA LCD 3U Rack UPS (100 V/120 V) |
53953JX |
3000VA LCD 3U Rack UPS (200 V/208 V) |
53956AX |
6000VA LCD 4U Rack UPS (200 V/208 V) |
53956KX |
6000VA LCD 4U Rack UPS (230 V) |
53959KX |
11000VA LCD 5U Rack UPS (200V/208V/230V) |
24195KX |
UPS5000 |
21303RX |
UPS 7500XHV |
21304RX |
UPS 10000XHV |
For more information, see the list of Lenovo Press Product Guides in the Power infrastructure category at this website:
http://lenovopress.com/systemx/power
Power distribution units
The server supports attachments to the power distribution units (PDUs) are listed in the following table.
Table 35. Power distribution units
Part number |
Description |
Switched and Monitored PDUs |
46M4002 |
1U 9 C19/3 C13 Active Energy Manager DPI PDU |
46M4003 |
1U 9 C19/3 C13 Active Energy Manager 60A 3 Phase PDU |
46M4004 |
1U 12 C13 Active Energy Manager DPI PDU |
46M4005 |
1U 12 C13 Active Energy Manager 60A 3 Phase PDU |
46M4167 |
1U 9 C19/3 C13 Switched and Monitored 30A 3 Phase PDU |
46M4116 |
0U 24 C13 Switched and Monitored 30A PDU |
46M4119 |
0U 24 C13 Switched and Monitored 32A PDU |
46M4134 |
0U 12 C19/12 C13 Switched and Monitored 50A 3 Phase PDU |
46M4137 |
0U 12 C19/12 C13 Switched and Monitored 32A 3 Phase PDU |
Enterprise PDUs |
71762MX |
Ultra Density Enterprise PDU C19 PDU+ (WW) |
71762NX |
Ultra Density Enterprise PDU C19 PDU (WW) |
71763MU |
Ultra Density Enterprise PDU C19 3 Phase 60A PDU+ (NA) |
71763NU |
Ultra Density Enterprise PDU C19 3 Phase 60A PDU (NA) |
39M2816 |
DPI C13 Enterprise PDU without line cord |
39Y8923 |
DPI 60A Three Phase C19 Enterprise PDU with IEC309 3P+G (208 V) fixed line cord |
39Y8941 |
DPI Single Phase C13 Enterprise PDU without line cord |
39Y8948 |
DPI Single Phase C19 Enterprise PDU without line cord |
Front-end PDUs |
39Y8934 |
DPI 32 amp/250 V Front-end PDU with IEC 309 2P+Gnd connector |
39Y8935 |
DPI 63 amp/250 V Front-end PDU with IEC 309 2P+Gnd connector |
39Y8938 |
30 amp/125 V Front-end PDU with NEMA L5-30P connector |
39Y8939 |
30 amp/250 V Front-end PDU with NEMA L6-30P connector |
39Y8940 |
60 amp/250 V Front-end PDU with IEC 309 60A 2P+N+Gnd connector |
Universal PDUs |
39Y8951 |
DPI Universal Rack PDU with US LV and HV line cords |
39Y8952 |
DPI Universal Rack PDU with CEE7-VII Europe LC |
39Y8953 |
DPI Universal Rack PDU with Denmark LC |
39Y8954 |
DPI Universal Rack PDU with Israel LC |
39Y8955 |
DPI Universal Rack PDU with Italy LC |
39Y8956 |
DPI Universal Rack PDU with South Africa LC |
39Y8957 |
DPI Universal Rack PDU with UK LC |
39Y8958 |
DPI Universal Rack PDU with AS/NZ LC |
39Y8959 |
DPI Universal Rack PDU with China LC |
39Y8962 |
DPI Universal Rack PDU (Argentina) |
39Y8960 |
DPI Universal Rack PDU (Brazil) |
39Y8961 |
DPI Universal Rack PDU (India) |
0U Basic PDUs |
46M4122 |
0U 24 C13 16A 3 Phase PDU |
46M4125 |
0U 24 C13 30A 3 Phase PDU |
46M4128 |
0U 24 C13 30A PDU |
46M4131 |
0U 24 C13 32A PDU |
46M4140 |
0U 12 C19/12 C13 60A 3 Phase PDU |
46M4143 |
0U 12 C19/12 C13 32A 3 Phase PDU |
For more information, see the list of Lenovo Press Product Guides in the Power infrastructure category at this website:
http://lenovopress.com/systemx/power
Rack options
The x3500 M5 server can be installed in the rack with the Tower to Rack Conversion Kit (00AL538). The resulting server is a 5U rack-mountable server, as shown in the following figure.
Figure 15. The x3500 M5 with the 5U Tower to Rack Conversion Kit (included slide kit shown)
The Tower to Rack Conversion Kit (00AL538) includes a cable management arm; however, standard rack models (for example, 5464-C3x and G3x) do not include a cable management arm. Thefore, the arm must be ordered separately by using part number 00KC334.
The tower-to-rack conversion kit, supported cable management arm kit, rack console switches, monitor kits, and management gateways are listed in the following table.
Table 36. Rack options
Part number |
Feature code |
Description |
Rack options for the x3500 M5 |
00KC334 |
ARZ2 |
System x3500 M5 Cable Management Kit |
00AL538 |
A5N4 |
System x3500 M5 Tower to Rack Conversion Kit |
Monitor kits and keyboard trays |
17238BX |
1723HC1 fc A3EK |
1U 18.5" Standard Console |
17238EX |
1723HC1 fc A3EL |
1U 18.5" Enhanced Media Console |
Console switches |
1754D2X |
1754HC2 fc 6695 |
Global 4x2x32 Console Manager (GCM32) |
1754D1X |
1754HC1 fc 6694 |
Global 2x2x16 Console Manager (GCM16) |
1754A2X |
1754HC4 fc 0726 |
Local 2x16 Console Manager (LCM16) |
1754A1X |
1754HC3 fc 0725 |
Local 1x8 Console Manager (LCM8) |
Console cables |
43V6147 |
3757 |
Single Cable USB Conversion Option (UCO) |
39M2895 |
3756 |
USB Conversion Option (4 Pack UCO) |
46M5383 |
5341 |
Virtual Media Conversion Option Gen2 (VCO2) |
46M5382 |
5340 |
Serial Conversion Option (SCO) |
Universal management gateway and cables |
3858D3X |
3858HC1 fc A4X1 |
Avocent Universal Management Gateway 6000 |
00AK142 |
A4X4 |
UM KVM Module VGA+SD Dual RJ45 |
For more information, see the list of Lenovo Press Product Guides in the Rack cabinets and options category at this website:
http://lenovopress.com/systemx/rack
Rack cabinets
Supported rack cabinets are listed in the following table.
Table 37. Rack cabinets
Part number |
Description |
Tower to rack conversion kits |
00KC334 |
System x3500 M5 Cable Management Kit |
00AL538 |
System x3500 M5 Tower to Rack Conversion Kit |
Rack cabinets |
201886X |
11U Office Enablement Kit |
93072RX |
25U Standard Rack |
93072PX |
25U Static S2 Standard Rack |
93634EX |
42U 1100mm Dynamic Expansion Rack |
93634PX |
42U 1100mm Dynamic Rack |
93604EX |
42U 1200mm Deep Dynamic Expansion Rack |
93604PX |
42U 1200mm Deep Dynamic Rack |
93614EX |
42U 1200mm Deep Static Expansion Rack |
93614PX |
42U 1200mm Deep Static Rack |
93084EX |
42U Enterprise Expansion Rack |
93084PX |
42U Enterprise Rack |
93074RX |
42U Standard Rack |
93074XX |
42U Standard Rack Extension |
93624EX |
47U 1200mm Deep Static Expansion Rack |
93624PX |
47U 1200mm Deep Static Rack |
93634BX |
PureFlex® System 42U Expansion Rack |
93634DX |
PureFlex System 42U Expansion Rack |
93634AX |
PureFlex System 42U Rack |
93634CX |
PureFlex System 42U Rack |
For more information, see the list of Lenovo Press Product Guides in the Rack cabinets and options category at this website:
http://lenovopress.com/systemx/rack