Description
|
Specifications
|
Form factor/height
|
4U/5U with tower-to-rack kit |
Processor
|
Xeon 4C E3-1220v3 80W 3.1GHz/1600MHz/8MB/ Up to one Intel Xeon E3-1200 v3 series (quad-core), i3 series (dual-core), Pentium series (dual-core), or Celeron processor (dual-core) |
Cache
|
UP to 8 MB per processor (model dependent) |
Memory
|
4GB RAM DDR3/ Up to 32 GB with four DDR3 DIMM slots supporting UDIMMs. RDIMMs are not supported |
Media bays
|
Up to two 5.25-inch half-high bays, support for DVD-ROM or multiburner, half-high SATA DVD-ROM standard in standard models |
Disk bays (total)
|
Bay SS 3.5in SATA/ Up to four 3.5-inch or eight 2.5-inch hard disk drives (HDDs) |
RAID support
|
Integrated ServeRAID C100 RAID-0, -1, (RAID-5 upgrade via Feature on Demand (FoD)), optional hardware RAID-0, -1, -10 or RAID-5, -50 or RAID-6, -60* |
Power supply
|
1/2 300 W or 350 W fixed (4U models); or 430 W 80 PLUS Silver certified redundant power supply unit (5U models) |
Hot-swap components
|
Up to four 3.5-inch or eight 2.5-inch HDDs, 460 W hot-swap redundant power supplies |
Network interface
|
2 x 1 Gigabit Ethernet |
Expansion slots
|
Up to four PCIe (2 PCIe 3.0, 2 PCIe 2.0) slots (x16, x8, x8, x4 physical; x8, x8, x4, x1 electrical) |
USB ports
|
2 front (USB 3.0)/4 back (USB 2.0)/2 internal |
Maximum internal storage
|
Up to 24 TB |
Energy efficiency
|
Fixed power supply compliant with 80 PLUS Bronze, redundant power supply compliant with 80 PLUS Silver, 40° C operating temperature for wide ambient range |
Systems management
|
Integrated Management Module 2 (IMM2) standard with IMPI 2.0 and Serial over LAN, optional upgrade to remote presence via Feature on Demand, IBM Systems Director |
Operating systems supported
|
Microsoft Windows Server 2012/2008/R2, SBS 2011, Red Hat Enterprise Linux, SUSE Linux, VMware (subject to availability) |
Limited warranty
|
1-year customer replaceable unit and on-site limited warranty, next business day 9x5, service upgrades available |
Introduction
The System x3100 M5 single-socket tower server is designed for small businesses and first-time server buyers looking for a solution to improve business efficiency. It delivers several innovative features with a competitive price, either in a compact mini-tower form factor, or standard tower form factor with hot-swap power supplies and disk drives. The System x3100 M5 provides next-generation performance in an innovative and compact design with flexible configuration options, built-in security, and systems management capabilities. It leverages the next-generation dual-core and quad-core Intel Xeon processor technology.
Suggested uses: Retail/kiosks, and SMBs, looking for file and printer servers, web serving, small business infrastructure, and virtual desktops for small workgroups.
Figure 1. The System x3100 M5 (compact mini-tower shown)
Did you know?
The System x3100 M5 server is a compact, cost-effective, single-processor tower or rack-mountable server that has been optimized to provide outstanding availability, manageability, and performance features to small-to-medium-sized businesses, retail stores, or distributed enterprises. It supports the Intel Xeon E3-1200 v3 “Haswell” family of processors for applications that require performance and stability, and Core i3, Pentium, and Celeron processors for applications that require lower cost.
The system includes features that are not typically seen in this class of system, such as standard, embedded RAID 0 and RAID 1, remote control capabilities even when the machine is powered off, and Predictive Failure Analysis (PFA) on processor and memory. Some models also support hot-swap redundant power supplies and hot-swap disk drives.
Key features
Often, small-to-medium sized businesses (SMBs) have limited IT budget and resources, and rely on partners or multitalented employees to help manage the company’s network. Business needs for efficiency improvement and retention of critical data require the usage of a server that is easy to get up and running quickly and is dependable. You need to squeeze as much as possible out of your IT dollars while saving costs on features that are not needed in an SMB environment. The System x3100 M5 is an ideal first server to meet those business needs. It was built for speed, yet eliminates costly design features that are found in general-purpose servers that are unnecessary for smaller businesses.
Scalability and performance
The x3100 M5 offers numerous features to boost performance, improve scalability, and reduce costs:
- The single-socket x3100 M5 supports the quad-core Intel Xeon Processor E3-1200 v3 ("Haswell") family of processors, which offer impressive computing power in a space-saving mini-tower design.
- Choice of processors with up to four cores to enable the effective usage of multi-threaded applications.
- Intel Xeon Processor E3-1200 v3 family supports Intel Hyper-Threading Technology and Intel Turbo Boost Technology 2.0 to maximize performance.
- Up to 32 GB of high-speed DDR3 system memory with four DIMM sockets.
- Memory speeds up to 1600 MHz.
- Four available high-performance PCI Express 3.0 or 2.0 slots.
- Up to four internal 3.5-inch simple-swap or hot-swap SATA II HDDs on some models offer low-cost/high-capacity storage.
- Up to eight internal 2.5-inch hot-swap SAS/SATA HDDs on some models offers maximum scalability and performance.
- Integrated ServeRAID-C100 software RAID controller supports RAID 0, 1, and 10. Hardware RAID options are available.
- Integrated dual-port Gigabit Ethernet provides increased network throughput and redundancy with efficient slot-saving integration.
- An available 5.25-inch drive bay supports either a half-high tape drive or an RDX Removable Disk Cartridge drive, for cost-effective data backup. A DVD-ROM drive is standard in a dedicated bay.
- Seven USB ports, two USB 3.0 on the front and four USB 2.0 on the back. In addition, there is one internal port for use with a tape drive or RDX Removable Disk Cartridge drive.
Availability and serviceability
The x3100 M5 provides many features to simplify serviceability and increase system uptime:
- ECC memory provides error correction that is not available in PC-class “servers” that use parity memory. Avoiding system crashes (and data loss) because of soft memory errors can mean greater system uptime.
- Tool-less cover removal provides easy access to upgrades and serviceable parts, such as CPU, memory, and adapters.
- Hot-swap drive bays that are available on some models combined with RAID capabilities offer the potential of no downtime in the event of a drive failure.
- The Predictive Failure Analysis (PFA) detects when system components (for example, processors, memory, and hard disk drives) operate outside of standard thresholds and generates pro-active alerts in advance of possible failure, therefore increasing uptime.
- Built-in Integrated Management Module Version II (IMM2) continuously monitors system health, triggers alerts, and performs recovering actions in case of failures to minimize downtime.
- Built-in diagnostic tests using Dynamic Systems Analysis (DSA) Preboot speeds up troubleshooting tasks to reduce service time.
- A DVD-ROM drive is standard in a dedicated bay for easy software installation.
- Redundant hot-swap power supports on some models helps keep the server always running
- One-year customer replaceable unit and onsite limited warranty, next business day 9x5. Optional service upgrades are available.
Manageability and security
Powerful systems management features simplify local and remote management of the x3100 M5:
- The server includes an Integrated Management Module II (IMM2) to monitor server availability and perform remote management (some features require optional license upgrades).
- Integrated industry-standard Unified Extensible Firmware Interface (UEFI) enables improved setup, configuration, and updates, and simplifies error handling.
- Integrated Trusted Platform Module (TPM) 1.2 support enables advanced cryptographic functions, such as digital signatures and remote attestation.
- Intel Xeon Processor E3-1200 v3 family supports Industry-standard Advanced Encryption Standard (AES) NI support for faster, stronger encryption.
- IBM Systems Director is included for proactive systems management. It offers comprehensive systems management tools that help to increase up-time, reduce costs, and improve productivity through advanced server management capabilities.
- The Intel Execute Disable Bit function can help prevent certain classes of malicious buffer overflow attacks when combined with a supporting operating system.
Energy efficiency
The x3100 M5 offers the following energy-efficiency features to save energy, reduce operational costs, increase energy availability, and contribute to a green environment:
- Energy-efficient planar components help lower operational costs.
- Available 350 W power supply, 300 W 80 PLUS Bronze certified power supply, or 430 W hot-swap 80 PLUS Silver certified power supply.
- With the addition of the Operating Temperature Enhancement Kit, the server supports the ASHRAE A3 standard, which means the server can operate in temperatures as high as 40°C. This means potential savings in environmental cooling costs.
- The Intel Xeon processor E3-1200 v3 product family offers significantly better performance over the previous generation while fitting into the same thermal design power (TDP) limits.
- Low-voltage Intel Xeon processors draw less energy to satisfy demands of power and thermally constrained data centers and telecommunication environments.
- The server uses hexagonal ventilation holes, a part of Calibrated Vectored Cooling™ technology. Hexagonal holes can be grouped more densely than round holes, providing more efficient airflow through the system.
Locations of key components
The x3100 M5 is available in two different tower designs: a compact tower with a fixed power supply and simple-swap drive bays, or a standard tower with hot-swap power supplies and hot-swap drive bays. Figures 2 and 3 show the front and rear of the x3100 M5.
Figure 2. Front view of the System x3100 M5 - compact tower and standard tower
Figure 3. Rear view of the System x3100 M5 - compact tower and standard tower
Figures 4 and 5 show the locations of key components inside the server.
Figure 4. Inside view of System x3100 M5 - compact tower configuration
Figure 5. Inside view of System x3100 M5 - standard tower configuration
Standard specifications
The following table lists the standard specifications.
Table 1. Standard specifications
Components |
Specification |
Machine type |
5457 |
Form factor |
Two designs:
- Compact tower (can be a 4U rack form factor using the optional Tower-to-Rack Conversion Kit, 69Y5182).
- Standard Tower (can be a 5U rack form factor using the optional Tower-to-Rack Conversion Kit, 00J6353).
|
Processor |
One Intel “Haswell” processor as listed in model table or available CTO:
- One 2-core Intel Celeron Processor 2.8 GHz and 1333 MHz memory.
- One 2-core Intel Pentium Processor up to 3.4 GHz and 1600 MHz memory.
- One 2-core Intel Core i3 Processor up to 3.7 GHz and 1600 MHz memory.
- One 2 or 4-core Intel Xeon E3-1200 v3 up to 3.7 GHz & 1600 MHz memory.
Supports EM64T for 32-bit and 64-bit operating systems and applications. |
L3 cache |
Integrated in the processor:
- Up to 2 MB for Intel Celeron processors.
- Up to 3 MB L3 for Intel Pentium processors.
- Up to 4 MB L3 for Intel Core i3 processors.
- Up to 8 MB L3 for Intel Xeon E3-1200 v3 processors.
|
Chip set |
Intel C222, formerly known as Intel Lynx Point PCH and Intel Denlow platform. |
Memory DIMM slots |
Four DDR3 DIMM slots supporting UDIMMs. RDIMMs are not supported. |
Memory capacity |
Up to 32 GB with 8 GB DDR3 UDIMMs and four populated DIMM slots. |
Memory protection |
ECC. |
Disk drive bays |
Compact tower: Up to four 3.5" simple-swap bays
Standard tower: Up to four 3.5" hot-swap bays (HDDs) or eight 2.5" hot-swap bays (HDDs or SSDs) |
Maximum internal storage |
Compact tower: Up to 12 TB with 3 TB 3.5" simple-swap NL SATA HDDs.
Standard tower: Up to 24 TB with 6 TB 3.5" hot-swap NL SATA HDDs or up to 8 TB with 1 TB 2.5" hot-swap NL SAS HDDs or upto 12.8 TB with 1.6 TB 2.5" hot-swap SSDs |
RAID support |
Software RAID 0, 1, or 10 with ServeRAID C100 controller, upgradeable to RAID 5. Optional hardware RAID with ServeRAID H1110 (RAID 0, 1, 1E, or 10) or M1115 (RAID 0, 1, 10, optional RAID 5, or 50) or M5110 (RAID 0, 1, 10, optional 5, 50, 6, or 60, and optional cache with flash backup). Additional upgrades for M5110. For compact tower: using the hardware RAID adapter also requires a RAID upgrade kit (00J6352). |
Optical drive bays |
One 5.25" HH bay, support for DVD-ROM or multiburner. Half-High SATA DVD-ROM or multiburner included in standard models (model specific). |
Tape drive bays |
One 5.25" HH bay, support for DDS, RDX, or LTO drive. |
Network interfaces |
Integrated two-port Gigabit Ethernet (Broadcom BCM5717). One port is shared with the Integrated Management Module (IMM). |
PCI expansion slots |
Four PCI Express slots:
- Slot 1, PCIe 3.0 x16 (x8 wired), full-height, half-length.
- Slot 2, PCIe 3.0 x8 (x8 wired), full-height, half-length.
- Slot 2, PCIe 2.0 x8 (x4 wired), full-height, half-length.
- Slot 4, PCIe 2.0 x4 (x1 wired), full-height, half-length.
|
Ports |
Front: Two USB 3.0 ports. Rear: Four USB 2.0, one DB-15 video, one DB-9 serial, two RJ-45 Gigabit Ethernet network ports (one dedicated and one shared with the IMM2 management processor). Internal: One USB 2.0 port for internal USB tape drive. |
Cooling |
Compact tower: Up to two speed-controlled non-redundant fans. A second fan is required if two or more adapters are installed (Thermal Solution Fan kit, 46W9177, optional). Optional Operating Temperature Enhancement Kit, 00Y8197, to enable the server to operate in a 40°C environment.
Standard tower: Up to two speed-controlled non-redundant fans. A second fan is required if two or more adapters are installed (Thermal Solution Fan kit, 00Y8200, included in standard models). Optional Operating Temperature Enhancement Kit, 00FK940, to enable the server to operate in a 40°C environment. |
Power supply |
Compact tower: One fixed (non-hot-swap) power supply, model dependent: Either 300 W ac 80 PLUS Bronze power supply or 350 W ac power supply.
Standard tower: Up to two 430 W hot-swap 80 PLUS Silver redundant power supplies. |
Hot-swap parts |
Compact tower: None.
Standard tower: Disk drive bays and power supplies. |
Systems management |
UEFI, Integrated Management Module II (IMM2), basic light path diagnostic tests, Automatic Server Restart, IBM Systems Director, and ServerGuide. Optional IMM Advanced FoD Upgrade for remote presence (graphics, keyboard and mouse, and virtual media). |
Video |
Matrox G200eR2 with 16 MB memory that is integrated into the IMM2. Maximum resolution is 1600x1200 at 75 Hz with 16 M colors. |
Security features |
Power-on password, administrator password, and Trusted Platform Module. |
Operating systems supported |
Microsoft Windows Server 2008 R2, 2012, 2012 R2; RHEL 5; SLES 11 & 12; VMware ESX 5.1, 5.5; (no USB 3.0 support for RHEL 5.1 or VMware ESX 5.1, 5.5). |
Limited warranty |
One-year customer replaceable unit and onsite limited warranty with 9x5/ next-business-day (NBD) response time. |
Service and support |
Optional service upgrades available through ServicePac offerings: 24x7/NBD or four hours onsite repair, 1-year or 2-year warranty extension, remote technical support for Lenovo hardware and selected Lenovo and third-party (Microsoft, Linux, VMware) software. |
Dimensions |
Compact tower: Height: 360 mm (14.2"), width: 180 mm (7.1"), depth: 480 mm (18.9")
Standard tower: Height: 439 mm (17.3"), width: 217 mm (8.6"), depth: 569 mm (22.4") |
Weight |
Compact tower: Minimum configuration: 10 kg (22.0 lb), maximum: 13 kg (28.7 lb)
Standard tower: Minimum configuration: 19.6 kg (43 lb), maximum: 22 kg (48.5 lb) |
The x3100 M5 servers are shipped with the following items:
- Statement of Limited Warranty.
- Important Notices.
- Documentation CD that contains the Installation and Service Guide.
- Country-specific models might have one or two country-specific power cords.
Standard models
The following table lists the standard models.
Table 2. Standard models
Model |
Intel Processor*
(one maximum) |
Memory |
RAID
controller |
Disk
bays |
Disks |
Network |
Optical |
Power
supply |
Fans |
Compact tower form factor - simple-swap drives and fixed power supply |
5457-A3x |
Pentium G3440 3.3GHz
3MB 1600MHz 2C (54W) |
1x 4 GB
1600 MHz |
ServeRAID
C100 |
4x 3.5" SS |
Open |
2x GbE |
DVD |
1x 350W
fixed |
1 / 2 |
5457-B3x |
Xeon E3-1220 v3 3.1GHz
8MB 1600MHz 4C (80W) |
1x 4 GB
1600 MHz |
ServeRAID
C100 |
4x 3.5" SS |
Open |
2x GbE |
DVD |
1x 350W
fixed |
1 / 2 |
5457-C3x |
Xeon E3-1231 v3 3.4GHz
8MB 1600MHz 4C (80W) |
1x 4 GB
1600 MHz |
ServeRAID
C100 |
4x 3.5" SS |
Open |
2x GbE |
DVD |
1x 300W
fixed |
1 / 2 |
Standard tower form factor - hot-swap drives and power supplies |
5457-C5x |
Xeon E3-1231 v3 3.4GHz
8MB 1600MHz 4C (80W) |
1x 4 GB
1600 MHz |
ServeRAID
H1110 |
4x 3.5" HS |
Open |
2x GbE |
Multi-
burner |
1x 430W
hot-swap |
2 / 2 |
5457-F3x |
Xeon E3-1271 v3 3.6GHz
8MB 1600MHz 4C (80W) |
1x 4 GB
1600 MHz |
ServeRAID
M1115 |
8x 2.5” HS |
Open |
2x GbE |
Multi-
burner |
1x 430W
hot-swap |
2 / 2 |
* Processor detail: Processor quantity, processor model, core speed, number of cores, L3 cache, memory speed, and thermal design power (TDP) rating
Express models
Express models are preconfigured with additional components, such as processors, memory, and disks with the purpose of making the ordering and installation process simpler. The following table lists the Express models that are available in certain regions.
Table 3. Express models
Model |
Intel Processor*
(one maximum) |
Memory |
RAID
controller |
Disk
bays |
Disks |
Network |
Optical |
Power
supply |
Fans |
Compact tower form factor - simple-swap drives and fixed power supply |
5457-
EAx |
Core i3 4150 3.5GHz
3MB 1600MHz 2C (54W) |
1x 4 GB
1600 MHz |
ServeRAID
C100 |
4x 3.5" SS |
1x 1TB
NL SATA |
2x GbE |
DVD |
1x 350W
fixed |
1 / 2 |
5457-
EBx |
Xeon E3-1220 v3 3.1GHz
8MB 1600MHz 4C (80W) |
2x 8 GB
1600 MHz |
ServeRAID
C100 |
4x 3.5" SS |
Open |
2x GbE |
Multi-
burner |
1x 350W
fixed |
1 / 2 |
5457-
ECx |
Xeon E3-1220 v3 3.1GHz
8MB 1600MHz 4C (80W) |
1x 8 GB
1600 MHz |
ServeRAID
C100 |
4x 3.5" SS |
1x 1TB
NL SATA |
2x GbE |
Multi-
burner |
1x 350W
fixed |
1 / 2 |
5457-
EDx |
Xeon E3-1220 v3 3.1GHz
8MB 1600MHz 4C (80W) |
1x 8 GB
1600 MHz |
ServeRAID
C100 |
4x 3.5" SS |
2x 1TB
NL SATA |
2x GbE |
Multi-
burner |
1x 350W
fixed |
1 / 2 |
5457-
EFx |
Xeon E3-1231 v3 3.4GHz
8MB 1600MHz 4C (80W) |
1x 8 GB
1600 MHz |
ServeRAID
C100 |
4x 3.5" SS |
Open |
2x GbE |
Multi-
burner |
1x 350W
fixed |
1 / 2 |
Standard tower form factor - hot-swap drives and power supplies |
5457-
EEx |
Xeon E3-1220 v3 3.1GHz
8MB 1600MHz 4C (80W) |
1x 8 GB
1600 MHz |
ServeRAID
H1110 |
8x 2.5” HS |
Open |
2x GbE |
Multi-
burner |
1x 430W
hot-swap |
2 / 2 |
5457-
EGx |
Xeon E3-1220 v3 3.1GHz
8MB 1600MHz 4C (80W) |
1x 8 GB
1600 MHz |
ServeRAID
M1115 |
8x 2.5” HS |
1x 300GB
10K SAS |
2x GbE |
Multi-
burner |
1x 430W
hot-swap |
2 / 2 |
5457-
EHx |
Xeon E3-1220 v3 3.1GHz
8MB 1600MHz 4C (80W) |
1x 8 GB
1600 MHz |
ServeRAID
M1115 |
8x 2.5” HS |
Open |
2x GbE |
Multi-
burner |
2x 430W
hot-swap |
2 / 2 |
5457-
EJx |
Xeon E3-1271 v3 3.6GHz
8MB 1600MHz 4C (80W) |
1x 8 GB
1600 MHz |
ServeRAID
M1115 |
8x 2.5” HS |
Open |
2x GbE |
Multi-
burner |
1x 430W
hot-swap |
2 / 2 |
5457-
EKx |
Xeon E3-1271 v3 3.6GHz
8MB 1600MHz 4C (80W) |
2x 8 GB
1600 MHz |
ServeRAID
M5110† |
8x 2.5” HS |
Open |
2x GbE |
Multi-
burner |
2x 430W
hot-swap |
2 / 2 |
* Processor detail: Processor quantity, processor model, core speed, number of cores, L3 cache, memory speed, and thermal design power (TDP) rating
† Model EKx includes ServeRAID M5100 Series 512MB Flash/RAID 5 Upgrade for System x (81Y4487) and System x3100 Hardware RAID Remote Battery/Cap Mechanical kit (00J6455)
Processor options
The server supports only one processor, which is already installed in all standard and Express models. No additional processor options are available. The following table lists all processors that are available in standard models of x3100 M5 or through configure-to-order (CTO). If there is no corresponding where-used model for a particular processor, then that processor is only available through the CTO process or special bid.
Table 4. Processor options
Feature
code* |
Description** |
Standard models
where used |
A58S |
Intel Celeron Processor G1840 2.8GHz 2MB 1333MHz 2C (53W) |
- |
A58D |
Intel Core i3 Processor 4150 3.5GHz 3MB 1600MHz 2C (54W) |
EAx |
A58E |
Intel Core i3 Processor 4150T 3.0GHz 3MB 1600MHz 2C (35W) |
- |
A58C |
Intel Core i3 Processor 4350 3.6GHz 4MB 1600MHz 2C (54W) |
- |
A58B |
Intel Core i3 Processor 4360 3.7GHz 4MB 1600MHz 2C (54W) |
- |
A58R |
Intel Pentium Processor G3220 3.0GHz 3MB 1333MHz 2C (53W) |
- |
A58G |
Intel Pentium Processor G3240 3.1GHz 3MB 1333MHz 2C (53W) |
- |
A58H |
Intel Pentium Processor G3240T 2.7GHz 3MB 1333MHz 2C (35W) |
- |
A58J |
Intel Pentium Processor G3440 3.3GHz 3MB 1600MHz 2C (53W) |
A3x |
A58F |
Intel Pentium Processor G3450 3.4GHz 3MB 1600MHz 2C (53W) |
- |
A3QT |
Intel Xeon Processor E3-1220 v3 3.1GHz 8MB 1600MHz 4C (80W) |
B3x, EBx, ECx, EDx,
EEx, EGx, EHx |
A4VZ |
Intel Xeon Processor E3-1220L v3 1.1GHz 4MB 1600MHz 2C (13W) |
- |
A58K |
Intel Xeon Processor E3-1231 v3 3.4GHz 8MB 1600MHz 4C (80W) |
C3x, C5x, EFx |
A58Q |
Intel Xeon Processor E3-1240L v3 2.0GHz 8MB 1600MHz 4C (25W) |
- |
A58L |
Intel Xeon Processor E3-1241 v3 3.5GHz 8MB 1600MHz 4C (80W) |
- |
A58M |
Intel Xeon Processor E3-1271 v3 3.6GHz 8MB 1600MHz 4C (80W) |
EJx, EKx, F3x |
A58P |
Intel Xeon Processor E3-1275L v3 2.7GHz 8MB 1600MHz 4C (45W) |
- |
A58N |
Intel Xeon Processor E3-1281 v3 3.7GHz 8MB 1600MHz 4C (82W) |
- |
* No additional processor options are available. The server supports only one processor, which is already included in a standard or custom configuration.
** Processor detail: Processor model, core speed, L3 cache, memory speed, number of cores, and thermal design power (TDP) rating
Memory options
Lenovo DDR3 memory is compatibility tested and tuned for optimal System x performance and throughput. Lenovo memory specifications are integrated into the light path diagnostics for immediate system performance feedback and optimum system uptime. From a service and support standpoint, Lenovo memory automatically assumes the system warranty, and Lenovo provides service and support worldwide.
The x3100 M5 has four DIMM slots, and only DDR3 ECC UDIMMs are supported. The CPU has two memory channels, and there are two DIMMs per channel.
Configuration rules: If you plan to install more than one DIMM, then the DIMMs must be installed in a pair, and both DIMMs in a pair must be identical in type and size.
The following table lists the memory options that are supported by the server.
Table 5. Memory options
Part
number |
Feature
code |
Description |
Maximum
supported |
Standard models
where used |
00D5012 |
A3QB |
4GB (1x4GB, 2Rx8, 1.35V) PC3L-12800
CL11 ECC DDR3 1600MHz LP UDIMM |
4 |
A3x, B3x, C3x,
C5x, EAx, F3x |
00D5016 |
A3QC |
8GB (1x8GB, 2Rx8, 1.35V) PC3L-12800
CL11 ECC DDR3 1600MHz LP UDIMM |
4 |
All other models |
Internal drives
Models of the x3100 M5 with the compact tower form factor (and either a 300 W or a 350 W fixed power supply) support up to four 3.5-inch simple-swap SATA hard disk drives, as shown in the following figure.
Figure 6. Simple-swap drive bays of the compact tower models (accessible with the front bezel removed)
The following table lists the supported 3.5-inch hard disk drive options.
For information about 512e Advanced Format drives, see the Lenovo Press paper, Advanced Format HDD Technology Overview, available from:
http://lenovopress.com/redp5119
Table 6. Simple-swap 3.5-inch SATA disk drive options
Part number |
Feature
code |
Description |
Maximum
supported |
512e Advanced Format drives |
00FN118 |
A5VE |
2TB 7.2K 6Gbps NL SATA 3.5" G2SS 512e HDD |
4 |
00FN133 |
A5VG |
3TB 7.2K 6Gbps NL SATA 3.5" G2SS 512e HDD |
4 |
512-byte sector drives |
81Y9802 |
A22U |
500GB 7.2K 6Gbps NL SATA 3.5" G2SS HDD |
4 |
81Y9806 |
A22X |
1TB 7.2K 6Gbps NL SATA 3.5" G2SS HDD |
4 |
81Y9810 |
A22W |
2TB 7.2K 6Gbps NL SATA 3.5" G2SS HDD |
4 |
81Y9814 |
A22V |
3TB 7.2K 6Gbps NL SATA 3.5" G2SS HDD |
4 |
Models of the x3100 M5 using the standard tower chassis (and with hot-swap 430 W power supplies) support either up to eight 2.5-inch hot-swap drives or four 3.5-inch hot-swap drives, as shown in the following figure.
Figure 7. Hot-swap drives that are supported in standard tower models with hot-swap power supplies (front bezel removed) - 4x 3.5-inch (left) or 8x 2.5-inch (right)
The following table lists the supported 2.5-inch drive options. Hot-swap SATA HDDs and hot-swap SAS HDDs can be intermixed, but not in the same array.
Table 7. 2.5-inch hot-swap disk drive options
Part number |
Feature
code |
Description |
Maximum
supported |
2.5-inch 10K SAS HDDs |
90Y8877 |
A2XC |
300GB 10K 6Gbps SAS 2.5" SFF G2HS HDD |
8 |
90Y8872 |
A2XD |
600GB 10K 6Gbps SAS 2.5" SFF G2HS HDD |
8 |
81Y9650 |
A282 |
900GB 10K 6Gbps SAS 2.5" SFF HS HDD |
8 |
2.5-inch 15K SAS HDDs |
90Y8926 |
A2XB |
146GB 15K 6Gbps SAS 2.5" SFF G2HS HDD |
8 |
81Y9670 |
A283 |
300GB 15K 6Gbps SAS 2.5" G2HS HDD |
8 |
2.5-inch SAS self-encrypting drives (SEDs) |
90Y8908 |
A3EF |
600GB 10K 6Gbps SAS 2.5" SFF G2HS SED |
8 |
81Y9662 |
A3EG |
900GB 10K 6Gbps SAS 2.5" SFF G2HS SED |
8 |
2.5-inch NL SAS HDDs |
90Y8953 |
A2XE |
500GB 7.2K 6Gbps NL SAS 2.5" SFF G2HS HDD |
8 |
81Y9690 |
A1P3 |
1TB 7.2K 6Gbps NL SAS 2.5" SFF HS HDD |
8 |
2.5-inch NL SATA HDDs |
81Y9722 |
A1NX |
250GB 7.2K 6Gbps NL SATA 2.5" SFF HS HDD |
8 |
81Y9726 |
A1NZ |
500GB 7.2K 6Gbps NL SATA 2.5" SFF HS HDD |
8 |
81Y9730 |
A1AV |
1TB 7.2K 6Gbps NL SATA 2.5" SFF HS HDD |
8 |
2.5-inch Enterprise Value SSDs |
00FN298 |
AS0D |
240GB SATA 2.5" MLC HS Entry SSD |
8 |
00FN327 |
AS0E |
480GB SATA 2.5" MLC HS Entry SSD |
8 |
00FN332 |
AS0F |
960GB SATA 2.5" MLC HS Entry SSD |
8 |
00FN268 |
A5U4 |
S3500 1.6TB SATA 2.5" MLC HS Enterprise Value SSD |
8 |
2.5-inch Enterprise SSDs |
41Y8331 |
A4FL |
S3700 200GB SATA 2.5" MLC HS Enterprise SSD for System x |
8 |
41Y8336 |
A4FN |
S3700 400GB SATA 2.5" MLC HS Enterprise SSD for System x |
8 |
41Y8341 |
A4FQ |
S3700 800GB SATA 2.5" MLC HS Enterprise SSD for System x |
8 |
49Y6129 |
A3EW |
200GB SAS 2.5" MLC HS Enterprise SSD |
8 |
49Y6134 |
A3EY |
400GB SAS 2.5" MLC HS Enterprise SSD |
8 |
49Y6139 |
A3F0 |
800GB SAS 2.5" MLC HS Enterprise SSD |
8 |
The following table lists the supported 3.5-inch hot-swap drives.
Table 8. 3.5-inch hot-swap disk drive options
Part number |
Feature
code |
Description |
Maximum
supported |
3.5-inch 15K SAS HDDs - 512-byte sector drives |
49Y6092 |
A3DV |
300GB 15K 6Gbps SAS 3.5" G2HS HDD |
4 |
49Y6097 |
A3DW |
450GB 15K 6Gbps SAS 3.5" G2HS HDD |
4 |
49Y6102 |
A3DX |
600GB 15K 6Gbps SAS 3.5" G2HS HDD |
4 |
3.5-inch NL SATA HDDs - 512-byte sector drives |
81Y9786 |
A22Y |
500GB 7.2K 6Gbps NL SATA 3.5" G2HS HDD |
4 |
81Y9790 |
A22P |
1TB 7.2K 6Gbps NL SATA 3.5" G2HS HDD |
4 |
81Y9794 |
A22T |
2TB 7.2K 6Gbps NL SATA 3.5" G2HS HDD |
4 |
81Y9798 |
A22S |
3TB 7.2K 6Gbps NL SATA 3.5" G2HS HDD |
4 |
49Y6002 |
A3W9 |
4TB 7.2K 6Gbps NL SATA 3.5" G2HS HDD |
4 |
3.5-inch NL SATA HDDs - 512e Advanced Format drives |
00FN113 |
A5VD |
2TB 7.2K 6Gbps NL SATA 3.5" G2HS 512e HDD |
4 |
00FN128 |
A5VF |
3TB 7.2K 6Gbps NL SATA 3.5" G2HS 512e HDD |
4 |
00FN143 |
A5VH |
4TB 7.2K 6Gbps NL SATA 3.5" G2HS 512e HDD |
4 |
00FN158 |
A5VK |
5TB 7.2K 6Gbps NL SATA 3.5" G2HS 512e HDD |
4 |
00FN173 |
A5VM |
6TB 7.2K 6Gbps NL SATA 3.5" G2HS 512e HDD |
4 |
3.5-inch NL SAS HDDs - 512e Advanced Format drives |
00ML203 |
AS76 |
2TB 7.2K 6Gbps NL SAS 3.5" G2HS 512e HDD |
4 |
00ML208 |
AS77 |
4TB 7.2K 6Gbps NL SAS 3.5" G2HS 512e HDD |
4 |
00ML213 |
AS78 |
6TB 7.2K 6Gbps NL SAS 3.5" G2HS 512e HDD |
4 |
3.5-inch NL SAS self-encyrping drives (SEDs) - 512e Advanced Format drives |
00ML218 |
AS79 |
2TB 7.2K 6Gbps NL SAS 3.5" G2HS 512e SED |
4 |
00ML223 |
AS7A |
4TB 7.2K 6Gbps NL SAS 3.5" G2HS 512e SED |
4 |
00ML228 |
AS7B |
6TB 7.2K 6Gbps NL SAS 3.5" G2HS 512e SED |
4 |
Controllers for internal storage
The Integrated ServeRAID C100 disk controller offers RAID 0, 1, and 10 standard. The ServeRAID C100 is an integrated SATA controller with software RAID capabilities. It is a cost-effective way to provide reliability, performance, and fault-tolerant disk subsystem management to help safeguard your valuable data and enhance availability. The ServeRAID C100 has the following specifications:
- Supports RAID levels 0, 1, and 10
- Onboard SATA controller with software RAID capabilities
- Supports 3 Gbps SATA ports
- Support for up to two virtual drives
- Support for virtual drive sizes greater than 2 TB
- Fixed stripe unit size of 64 KB
- Support for MegaRAID Storage Manager management software
The following table lists the RAID controller and internal HBAs that are supported by the server.
Table 9. RAID controllers and HBAs for internal storage
Part number |
Feature
code |
Description |
Maximum
supported |
Standard models
where used |
Integrated |
None |
ServeRAID C100 for System x |
1 |
All other models |
81Y4492 |
A1XL |
ServeRAID H1110 SAS/SATA Controller |
1 |
C5x, EEx |
81Y4448 |
A1MZ |
ServeRAID M1115 SAS/SATA Controller |
1 |
F3x, EGx, EHx, EJx |
81Y4481 |
A347 |
ServeRAID M5110 SAS/SATA Controller |
1 |
EKx |
46C8988 |
A3MW |
N2115 SAS/SATA HBA for System x |
1 |
- |
46M0907 |
5982 |
6Gb SAS HBA |
1 |
- |
The following table lists the supported upgrades to the internal RAID controllers and HBAs.
Table 10. Upgrades for internal storage controllers
Part number |
Feature
code |
Description |
Maximum
supported |
Models
where used |
Upgrades for the ServeRAID C100 |
81Y4406 |
A17U |
ServeRAID C100 Series RAID 5 Upgrade for System x-FoD |
1 |
- |
Upgrades for the ServeRAID M1115 SAS/SATA Controller |
81Y4542 |
A1X1 |
ServeRAID M1100 Series Zero Cache/RAID 5 Upgrade for System x |
1 |
- |
Upgrades for the ServeRAID M5110 SAS/SATA Controller |
81Y4508 |
A22E |
ServeRAID M5100 Series Battery Kit**
(Supported only with 512MB cache option, 81Y4484) |
1 |
- |
81Y4544 |
A1X2 |
ServeRAID M5100 Series Zero Cache/RAID 5 Upgrade for System x |
1 |
- |
81Y4484 |
A1J3 |
ServeRAID M5100 Series 512MB Cache/RAID 5 Upgrade for System x |
1 |
- |
81Y4487 |
A1J4 |
ServeRAID M5100 Series 512MB Flash/RAID 5 Upgrade for System x** |
1 |
EKx |
81Y4559 |
A1WY |
ServeRAID M5100 Series 1GB Flash/RAID 5 Upgrade for System x** |
1 |
- |
81Y4546 |
A1X3 |
ServeRAID M5100 Series RAID 6 Upgrade for System x |
1* |
- |
90Y4273 |
A2MC |
ServeRAID M5100 Series SSD Performance Key for System x |
1* |
- |
90Y4318 |
A2MD |
ServeRAID M5100 Series SSD Caching Enabler for System x |
1* |
- |
* A cache option (81Y4484, 81Y4487, or 81Y4559) must be selected.
** For the standard tower chassis only (hot-swap power supplies). Not supported in the compact tower chassis.
The following table lists chassis upgrades for RAID controllers.
Table 11. Chassis upgrades
Part number |
Feature code |
Description |
Maximum
supported |
Models
where used |
00J6352 |
A49A |
System x3100 3.5" Simple Swap HDD Hardware RAID upgrade kit
For the compact tower chassis only (fixed power supply) to enable support of RAID controllers; if selected then one of the following controllers is required: ServeRAID M1115, ServeRAID H1110, or N2115 HBA. Not supported the standard tower chassis. |
1 |
- |
00J6455 |
A3SE |
System x3100 Hardware RAID Remote Battery/Cap Mechanical kit
For the standard tower chassis only (hot-swap power supplies) to provide a housing for a battery or flash backup unit; required if the battery upgrade (81Y4508) or a flash upgrade is selected. Not supported in the compact tower chassis. |
1 |
EKx |
For more information, see the list of Lenovo Press Product Guides in the RAID adapters category:
http://lenovopress.com/systemx/raid
Internal backup units
The server supports the internal tape drive options that are listed in the following table. Internal tape drives are installed in a 5.25-inch HH bay. A maximum of one tape drive is supported. SAS tape drives require an internal SAS HBA to be installed in server. USB tape drives are connected to the dedicated USB tape drive connector on the system board.
Table 12. Internal tape drives
Part
number |
Feature
code |
Description |
Maximum
supported |
49Y9898 |
5345 |
Half High LTO Gen 5 SAS Tape Drive* |
1 |
00D2786 |
A2VE |
RDX Internal USB 3.0 Dock with 320GB Cartridge |
1 |
00D2787 |
A2VF |
RDX Internal USB 3.0 Dock with 500GB Cartridge |
1 |
00D2788 |
A2VG |
RDX Internal USB 3.0 Dock with 1TB Cartridge |
1 |
* Requires N2115 SAS/SATA HBA for System x (46C8988) or 6Gb SAS HBA (46M0907)
For more information, see the list of Lenovo Press Product Guides in the Backup units category:
http://lenovopress.com/systemx/tape
Optical drives
The server supports the optical drive options that are listed in the following table.
Table 13. Optical drives
Part number |
Feature
code |
Description |
Maximum
supported |
Standard models
where used |
None* |
4154 |
Half-High SATA DVD-ROM |
1 |
A3x, B3x, C3x, EAx |
81Y6404 |
4155 |
Half-High SATA Multi-Burner |
1 |
All other models |
* This option is only available through CTO or is already installed in standard models.
The Half-High SATA DVD-ROM supports the following media and speeds for reading:
- CD-ROM 48X
- CD-DA (DAE) 40X
- CD-R 48X
- CD-RW 40X
- DVD-ROM (single layer) 16X
- DVD-ROM (dual layer) 12X
- DVD-R (4.7 GB) 16X
- DVD-R DL 12X
- DVD+R 16X
- DVD+R DL 12X
- DVD-RW (4.7 GB) 12X
- DVD+RW 12X
- DVD-RAM (4.7/9.4 GB) 6X
The Half-High SATA Multi-Burner supports the same media and speeds for reading as HH DVD-ROM. In addition, this drive supports the following media and speeds for writing:
- CD-R 24X
- CD-RW 4X
- High Speed CD-RW 10X
- Ultra Speed CD-RW 16X
- DVD-R 8X
- DVD-R DL 8X
- DVD+R 8X
- DVD+R DL 8X
- DVD-RW 6X
- DVD+RW 8X
- DVD-RAM 3X
I/O expansion options
The server offers four PCI Express expansion slots. The form-factors of available slots are as follows. This applies to both the compact tower chassis and the standard tower chassis.
- Slot 1, PCIe 3.0 x16 (x8 wired), full-height, half-length
- Slot 2, PCIe 3.0 x8 (x8 wired), full-height, half-length
- Slot 3, PCIe 2.0 x8 (x4 wired), full-height, half-length
- Slot 4, PCIe 2.0 x4 (x1 wired), full-height, half-length
Network adapters
The x3100 M5 offers two integrated Gigabit Ethernet ports. One port is shared with Integrated Management Module II (IMM2), implementing Network Controller-Sideband Interface (NC-SI). The integrated NICs have the following features:
- Broadcom BCM5717 chip
- TCP/IP Offload Engine (TOE) support
- Wake on LAN support, Jumbo frame support
- Receive side Scaling (RSS) and Transmit side Scaling (TSS) support
- MSI and MSI-X capability- up to five MSI-X vectors
- VLAN tag support (IEEE 802.1Q), Layer 2 priority encoding (IEEE 802.1p)
- Link aggregation (IEEE 802.3ad) and Full-duplex flow control (IEEE 802.3x)
- IP, TCP, and UDP checksum offload (hardware based) on Tx/Rx over IPv4/IPv6
- Hardware TCP segmentation offload over IPv4/IPv6
- NIC Teaming (Load Balancing and Failover)
The following table lists additional supported network adapters.
Table 14. Network adapters
Part number |
Feature
code |
Description |
Maximum
supported |
Gigabit Ethernet |
90Y9370 |
A2V4 |
Broadcom NetXtreme I Dual Port GbE Adapter for System x |
2 |
90Y9352 |
A2V3 |
Broadcom NetXtreme I Quad Port GbE Adapter for System x |
3 |
49Y4230 |
5767 |
Intel Ethernet Dual Port Server Adapter I340-T2 for System x |
3 |
49Y4240 |
5768 |
Intel Ethernet Quad Port Server Adapter I340-T4 for System x |
3 |
00AG500 |
A56K |
Intel I350-F1 1xGbE Fiber Adapter for System x |
4 |
00AG510 |
A56L |
Intel I350-T2 2xGbE BaseT Adapter for System x |
4 |
00AG520 |
A56M |
Intel I350-T4 4xGbE BaseT Adapter for System x |
4 |
42C1750 |
2975 |
PRO/1000 PF Server Adapter |
3 |
10 Gigabit Ethernet |
49Y7910 |
A18Y |
Broadcom NetXtreme II Dual Port 10GBaseT Adapter for System x |
3 |
00D8540 |
A4XH |
Emulex Dual Port 10GbE SFP+ VFA IIIr for System x* |
3 |
95Y3760 |
A2U2 |
Emulex VFA III/IIIr FCoE/iSCSI License for System x (FoD)
(FCoE upgrade license for 00D8540) |
3 |
49Y7960 |
A2EC |
Intel X520 Dual Port 10GbE SFP+ Adapter for System x* |
3 |
49Y7970 |
A2ED |
Intel X540-T2 Dual Port 10GBaseT Adapter for System x |
3 |
00D9690 |
A3PM |
Mellanox ConnectX-3 10 GbE Adapter for System x* |
3 |
90Y4600 |
A3MR |
QLogic 8200 Dual Port 10GbE SFP+ VFA for System x* |
3 |
00Y5624 |
A3MT |
QLogic 8200 VFA FCoE/iSCSI License for System x (FoD)
(FCoE upgrade license for 90Y4600) |
3 |
* Require SFP+ optical transceivers or DAC cables that must be purchased separately.
For more information, see the list of Lenovo Press Product Guides in the Networking adapters category:
http://lenovopress.com/systemx/networkadapters
Storage host bus adapters
The following table lists the storage host bus adapters (HBAs) supported by x3100 M5 server.
Table 15. Storage adapters
Part number |
Feature
code |
Description |
Maximum
supported |
Fibre Channel - 16 Gb |
81Y1655 |
A2W5 |
Emulex 16Gb FC Single-port HBA for System x |
3 |
81Y1662 |
A2W6 |
Emulex 16Gb FC Dual-port HBA for System x |
3 |
81Y1668 |
A2XU |
Brocade 16Gb FC Single-port HBA for System x |
3 |
81Y1675 |
A2XV |
Brocade 16Gb FC Dual-port HBA for System x |
3 |
00Y3337 |
A3KW |
QLogic 16Gb FC Single-port HBA for System x |
3 |
00Y3341 |
A3KX |
QLogic 16Gb FC Dual-port HBA for System x |
3 |
Fibre Channel - 8 Gb |
42D0485 |
3580 |
Emulex 8 Gb FC Single-port HBA for System x |
3 |
42D0494 |
3581 |
Emulex 8 Gb FC Dual-port HBA for System x |
3 |
42D0501 |
3578 |
QLogic 8 Gb FC Single-port HBA for System x |
3 |
42D0510 |
3579 |
QLogic 8 Gb FC Dual-port HBA for System x |
3 |
46M6049 |
3589 |
Brocade 8 Gb FC Single-port HBA for System x |
3 |
46M6050 |
3591 |
Brocade 8 Gb FC Dual-port HBA for System x |
3 |
SAS |
46C9010 |
A3MV |
N2125 SAS/SATA HBA for System x |
3 |
46M0907 |
5982 |
6 Gb SAS HBA Controller |
3 |
For more information, see the list of Lenovo Press Product Guides in the Host bus adapters category:
http://lenovopress.com/systemx/hba
PCIe SSD adapters
The server does not support High IOPS SSD adapters.
Power supplies
Compact tower models either come with a single fixed 350 W ac power supply or a single fixed 80 PLUS Bronze 300 W ac power supply. There are no additional power supply options.
Standard tower models offer one or two hot-swap 430 W ac power supplies, which are 80 PLUS Silver certified. For models with only one power supply, the part number to order a second power supply is listed in the following table. Two power supplies that are installed form a redundant pair.
Table 16. Hot-swap power supply option
Part number |
Feature
code |
Description |
Maximum
supported |
00D3821 |
A2Z0 |
430W Redundant Power Supply |
1 |
Fans and cooling
Both the compact tower design (with a single fixed power supply) and the standard tower design (with hot-swap power supplies) come with one or two speed-controlled non-redundant fans, model dependent (see Table 2). The second fan is required if two or more adapters are installed, and the fan is configured by selecting the appropriate Thermal Solution Fan Kit, as listed in the following table.
If you want to operate the server in an environment up to 40°C (104°F), use the optional Operating Temperature Enhancement Kit that is listed in the table. This kit contains an additional thermal sensor.
Table 17. Cooling options
Part number |
Feature
code |
Description |
Maximum
supported |
For compact tower systems (with a fixed power supply) |
46W9177 |
A3SF |
System x3100 Thermal Solution Fan kit for 4U Tower |
1 |
00Y8197 |
A49B |
System x3100 Operating Temperature Enhancement Kit for 4U Tower |
1 |
For standard tower systems (with hot-swap power supplies) |
00Y8200 |
A49D |
System x3100 Thermal Solution Fan kit for 5U Tower |
1 |
00FK940 |
A49C |
System x3100 Operating Temperature Enhancement Kit for 5U Tower |
1 |
Integrated virtualization
The server supports VMware ESXi installed on a USB memory key. The key is installed in a USB socket inside the server. The following table lists the virtualization options.
Table 18. Hot-swap power supply option
Part number |
Feature
code |
Description |
Maximum
supported |
41Y8298 |
A2G0 |
Blank USB Memory Key for VMware ESXi Downloads |
1 |
41Y8385 |
A584 |
USB Memory Key for VMware ESXi 5.5 |
1 |
Remote management
The server contains Integrated Management Module II (IMM2), which provides advanced service-processor control, monitoring, and an alerting function. If an environmental condition exceeds a threshold or if a system component fails, the IMM2 lights LEDs to help you diagnose the problem, records the error in the event log, and alerts you to the problem. Optionally, the IMM2 also provides a virtual presence capability for remote server management capabilities.
The IMM provides remote server management through industry-standard interfaces:
- Intelligent Platform Management Interface (IPMI) Version 2.0
- Simple Network Management Protocol (SNMP) Version 3
- Common Information Model (CIM)
- Web browser
The optional Integrated Management Module Advanced Upgrade is required to enable the remote presence and blue-screen capture features. The remote presence feature provides the following functions:
- Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel colors, regardless of the system state
- Remotely accessing the server using the keyboard and mouse from a remote client
- Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote client, and mapping ISO and diskette image files as virtual drives that are available for use by the server
- Uploading a diskette image to the IMM memory and mapping it to the server as a virtual drive
The blue-screen capture feature captures the video display contents before the IMM restarts the server when the IMM detects an operating-system hang condition. A system administrator can use the blue-screen capture to assist in determining the cause of the hang condition. The following table lists the remote management option.
Table 19. Remote management option
Part
number |
Feature
code |
Description |
Maximum
supported |
Models
where used |
90Y3901 |
A1ML |
Integrated Management Module Advanced Upgrade |
1 |
- |
Supported operating systems
The server supports the following operating systems:
- Microsoft Windows Server 2008 R2
- Microsoft Windows Server 2012
- Microsoft Windows Server 2012 R2
- Red Hat Enterprise Linux 5 Server Edition
- Red Hat Enterprise Linux 5 Server x64 Edition
- SUSE Enterprise Linux Server (SLES) 12
- SUSE LINUX Enterprise Server 11 for AMD64/EM64T
- SUSE LINUX Enterprise Server 11 for x86
- SUSE Linux Enterprise Server 12 with XEN
- Toshiba 4690 Operating System V6
- VMware vSphere 5.1 (ESXi)
- VMware vSphere 5.5 (ESXi)
For the latest information about the specific versions and service levels that are supported and any other prerequisites, see the ServerProven® website:
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml
Physical and electrical specifications
Dimensions and weight - compact tower systems with a fixed power supply:
- Height: 360 mm (14.2 in.)
- Width: 180 mm (7.1 in.)
- Depth: 480 mm (18.9 in.)
- Weight:
- Minimum ship configuration: 10 kg (22.0 lb)
- Maximum ship configuration: 13 kg (28.7 lb)
Dimensions and weight - standard tower systems with redundant hot-swap power supplies:
- Height: 439 mm (17.3 in.)
- Width: 217 mm (8.6 in.)
- Depth: 569 mm (22.4 in.)
- Weight
- Minimum ship configuration: 19.6 kg (43 lb)
- Maximum ship configuration: 22.0 kg (48.5 lb)
Supported environment:
- Temperature
- Server on
- 10.0° to 35.0° C (50° to 95° F); altitude: 0 to 914.4 m (3,000 ft)
- 10.0° to 32.0° C (50° to 89.6° F); altitude: 914.4 m (3,000 ft) to 2,133.6 m (7,000 ft)
- Supports up to 40° C (104° F) when the Operating Temperature Enhancement Kit is installed
- Server off
- 10.0° to 43.0° C (50° to 109.4° F); maximum altitude: 2,133.6 m (7,000 ft)
- Shipping
- -40° to 60° C (-40° to 140° F)
- Relative humidity: 8 to 80%
- Maximum altitude: 2,133.6 m (7,000 ft)
Electrical:
430 watt power supply:
- 100 - 127 (nominal) V ac; 50 - 60 Hz; 6.0 A (maximum)
- 200 - 240 (nominal) V ac; 50 - 60 Hz; 3.0 A (maximum)
- Input kilovolt-amperes (kVA) (approximately)
- Minimum configuration: 0.100 kVA
- Maximum configuration: 0.506 kVA
350 watt power supply:
- 100 - 127 (nominal) V ac; 50 - 60 Hz; 7.0 A (maximum)
- 200 - 240 (nominal) V ac; 50 - 60 Hz; 3.5 A (maximum)
- Input kilovolt-amperes:
- Minimum configuration: 0.035 kVA
- Maximum configuration: 0.350 kVA
300 watt power supply:
- 100 - 127 (nominal) V ac; 50 - 60 Hz; 7.0 A (maximum)
- 200 - 240 (nominal) V ac; 50 - 60 Hz; 3.5 A (maximum)
- Input kilovolt-amperes:
- Minimum configuration: 0.035 kVA
- Maximum configuration: 0.350 kVA
Environmental data:
- BTU output
- Ship configuration: 341 Btu/hr (100 watts)
- Full configuration: 1726 Btu/hr (506 watts)
- Noise level
- Model with fixed power supply: 5.0 bels (idle), 5.0 bels (operating)
- Model with hot-swap power supply: 5.0 bels (idle), 5.0 bels (operating)
Warranty options
The x3100 M5 has a one-year warranty with 24x7 standard call center support and 9x5 Next Business Day onsite coverage. Also available are Lenovo Services warranty maintenance upgrades and post-warranty maintenance agreements, with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.
Lenovo warranty service upgrade offerings are country-specific. Not all warranty service upgrades are available in every country. For more information about Lenovo warranty service upgrade offerings that are available in your country, visit the Lenovo Services website:
https://www-304.ibm.com/sales/gss/download/spst/servicepac/extProductSelectorWWW.do
The following table explains warranty service definitions in more detail.
Table 20. Warranty service definitions
Term |
Description |
On-site service |
A service technician will arrive at the client’s location for equipment service. |
24x7x2 hour |
A service technician is scheduled to arrive at the client’s location within two hours after remote problem determination is completed. Lenovo provides service around the clock, every day, including Lenovo holidays. |
24x7x4 hour |
A service technician is scheduled to arrive at the client’s location within four hours after remote problem determination is completed. Lenovo provides service around the clock, every day, including Lenovo holidays. |
9x5x4 hour |
A service technician is scheduled to arrive at the client’s location within four business hours after remote problem determination is completed. Lenovo provides service 8:00 am - 5:00 pm in the client's local time zone, Monday-Friday, excluding Lenovo holidays. For example, if a customer reports an incident at 3:00 pm on Friday, the technician will arrive by 10:00 am the following Monday. |
9x5 next business day |
A service technician is scheduled to arrive at the client’s location on the business day after remote problem determination is completed. Lenovo provides service 8:00 am - 5:00 pm in the client's local time zone, Monday - Friday, excluding Lenovo holidays. Calls received after 4:00 pm local time require an extra business day for service dispatch. Next business day service is not guaranteed. |
Committed Repair |
Problems receive priority handling so that repairs are completed within the committed time of 6, 8, or 24 hours. Lenovo provides service 24 hours/day, every day, including Lenovo holidays. |
The following Lenovo warranty service upgrades are available:
- Warranty and maintenance service upgrades:
- Three, four, or five years of 9x5 or 24x7 service coverage
- Onsite response from next business day to 2 or 4 hours
- Committed repair service
- Warranty extension of up to 5 years
- Post warranty extensions
- Committed Repair Service
Committed Repair Services enhances the level of Warranty Service Upgrade or Post Warranty/Maintenance Service offering associated with the selected systems. Offerings vary and are available in select countries.
- Priority handling to meet defined time frames to restore the failing machine to good working condition
- Committed repair service levels are measured within the following coverage hours:
- 24x7x6: Service performed 24 hours per day, 7 days per week, within 6 hours
- 24x7x8: Service performed 24 hours per day, 7 days per week, within 8 hours
- 24x7x24: Service performed 24 hours per day, 7 days per week, within 24 hours
- Hard Drive Retention
Lenovo’s Hard Drive Retention service is a multi-drive hard drive retention offering that ensures your data is always under your control, regardless of the number of hard drives that are installed in your Lenovo server. In the unlikely event of a hard drive failure, you retain possession of your hard drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The Hard Drive Retention service can be purchased in convenient bundles with our warranty upgrades and extensions.
- Microcode Support
Keeping microcode current helps prevent hardware failures and security exposure. There are two levels of service: analysis of the installed base and analysis and update where required. Offerings vary by country and can be bundled with other warranty upgrades and extensions.
- Remote Technical Support Services (RTS)
RTS provides comprehensive technical call center support for covered servers, storage, operating systems, and applications. Providing a single source for support of hardware and software issues, RTS can reduce problem resolution time, decreasing the cost to address technical problems and increasing uptime. Offerings are available for Windows, Linux, IBM Systems Director, VMware, Microsoft business applications, and Lenovo System x storage devices, and IBM OEM storage devices.
Back to top
Regulatory compliance
The server conforms to the following international standards:
- ASHRAE A3
- FCC - Verified to comply with Part 15 of the FCC Rules, Class A
- Canada ICES003, issue 5, Class A
- UL/IEC 60950-1
- CSA C22.2 No. 60950-1
- NOM-019
- Argentina IEC60950-1
- Japan VCCI, Class A
- Australia/New Zealand AS/NZS CISPR 22, Class A; AS/NZS 60950.1
- IEC-60950-1 (CB Certificate and CB Test Report)
- China CCC GB4943.1, GB9254 Class A, and GB17625.1
- Taiwan BSMI CNS13438, Class A); CNS14336-1
- Korea KN22, Class A; KN24
- Russia, Belorussia and Kazakhstan, TR CU 020/2011 (for EMC) and TR CU004/2011 (for safety)
- IEC 60950-1 (CB Certificate and CB Test Report)
- CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, and EN61000-3-3)
- CISPR 22, Class A
- TUV-GS (EN60950-1 /IEC60950-1, EK1-ITB2000)
Back to top
External disk storage expansion
The x3100 M5 supports attachment to external storage expansion enclosures, such as the EXP2500 series, by using either the ServeRAID M5225 or ServeRAID M5120 RAID controllers. The server can also be attached to supported external storage systems by using a supported HBA.
Table 21. RAID controllers and options for external disk storage expansion
Part number |
Feature
code |
Description |
Maximum
supported |
00AE938 |
A5ND |
ServeRAID M5225-2GB SAS/SATA Controller for System x |
1 |
81Y4478 |
A1WX |
ServeRAID M5120 SAS/SATA Controller |
3 |
Hardware upgrades for the M5120 |
81Y4508 |
A22E |
ServeRAID M5100 Series Battery Kit**
(Supported only with 512MB cache option, 81Y4484) |
1* |
00J6455 |
A3SE |
System x3100 Hardware RAID Remote Battery/Cap Mechanical kit** |
1 |
81Y4484 |
A1J3 |
ServeRAID M5100 Series 512MB Cache/RAID 5 Upgrade |
3 |
81Y4487 |
A1J4 |
ServeRAID M5100 Series 512MB Flash/RAID 5 Upgrade** |
1 |
81Y4559 |
A1WY |
ServeRAID M5100 Series 1GB Flash/RAID 5 Upgrade** |
1 |
Feature on Demand upgrades for the M5120 |
81Y4544 |
A1X2 |
ServeRAID M5100 Series Zero Cache/RAID 5 Upgrade |
1 |
90Y4318 |
A2MD |
ServeRAID M5100 Series SSD Caching Enabler |
1 |
90Y4273 |
A2MC |
ServeRAID M5100 Series SSD Performance Key |
1 |
81Y4546 |
A1X3 |
ServeRAID M5100 Series RAID 6 Upgrade |
1† |
Feature on Demand upgrades for the M5225 |
47C8706 |
A3Z5 |
ServeRAID M5200 Series RAID 6 Upgrade for Systems-FoD |
1 |
47C8710 |
A3Z7 |
ServeRAID M5200 Series Performance Accelerator for Systems-FoD |
1 |
47C8712 |
A3Z8 |
ServeRAID M5200 Series SSD Caching Enabler for Systems-FoD |
1 |
* The ServeRAID M5100 Series Battery Kit (81Y4508) is supported only with ServeRAID M5100 Series 512MB Cache/RAID 5 Upgrade (81Y4484).
† The ServeRAID M5100 Series RAID 6 Upgrade (81Y4546) requires a cache upgrade (either 81Y4484, 81Y4487, or 81Y4559).
** For the standard tower chassis only (hot-swap power supplies). Not supported in the compact tower chassis.
The ServeRAID M5225-2GB SAS/SATA Controller has the following specifications:
- Eight external 12 Gbps SAS/SATA ports
- Two external x4 mini-SAS HD connectors (SFF-8643)
- Supports RAID levels 0, 1, 10, 5, 50 standard
- Optional support for RAID 6 and 60 with the M5200 Series RAID 6 Upgrade
- 2 GB flash-backed cache standard
- PCIe x8 3.0 host interface
- Based on the LSI SAS3108 12 Gbps ROC controller
For more information about the ServeRAID M5225, see the Lenovo Press Product Guide at http://lenovopress.com/tips1258
The ServeRAID M5120 SAS/SATA Controller has the following specifications:
- Eight external 6 Gbps SAS/SATA ports
- Two external x4 mini-SAS connectors (SFF-8088)
- Supports RAID levels 0, 1, and 10
- Supports RAID levels 5 and 50 with optional M5100 Series RAID 5 upgrades
- Supports RAID 6 and 60 with the optional M5100 Series RAID 6 Upgrade
- Supports 512 MB battery-backed cache or 512 MB or 1 GB flash-backed cache
- 6 Gbps throughput per port
- PCIe x8 Gen 3 host interface
- Based on the LSI SAS2208 6 Gbps ROC controller
- Supports connectivity to the EXP2512 and EXP2524 storage expansion enclosures
Cache upgrade required: The ServeRAID M5120 SAS/SATA Controller ships standard without a cache. One of the available cache upgrades (81Y4484, 81Y4487, or 81Y4559) is required for the M5120 adapter operations, and it must be purchased together with the controller.
For more information about the ServeRAID M5120, see the Lenovo Press Product Guide at http://lenovopress.com/tips0858
The ServeRAID M5120 SAS/SATA Controller supports connectivity to the external expansion enclosures that are listed in the following table. Up to nine expansion enclosures can be daisy-chained per one M5120 external port. For better performance, distribute expansion enclosures evenly across both M5120 ports.
Table 22. External expansion enclosures
Part number |
Description |
Maximum quantity supported per one adapter |
70F0 / 70F1 |
Lenovo ThinkServer SA120 |
8 |
610012X |
EXP2512 Storage Enclosure |
17 |
610024X |
EXP2524 Storage Enclosure |
9 |
Lenovo ThinkServer SA120 support
For details about supported drives and cables for the Lenovo ThinkServer SA120, see the Lenovo Press Product Guide:
http://lenovopress.com/tips1234
EXP2512 and EXP2524 support
The external SAS cables that are listed in the following table support connectivity between external expansion enclosures and the ServeRAID M5120 SAS/SATA Controller.
Table 23. External SAS cables for external storage expansion enclosures
Part number |
Feature code |
Description |
Quantity supported
per one enclosure |
Cables for use with M5120 controller |
39R6531 |
3707 |
3 m SAS Cable |
1 |
39R6529 |
3708 |
1 m SAS Cable |
1 |
Cables for use with M5225 controller |
00Y2459 |
|
0.6m SAS Cable (mSAS HD to mSAS) |
1 |
00Y2461 |
|
1.5m SAS Cable (mSAS HD to mSAS) |
1 |
00Y2463 |
|
3m SAS Cable (mSAS HD to mSAS) |
1 |
90Y7682 |
|
6m SAS Cable (mSAS HD to mSAS) |
1 |
The following table lists the drives that are supported by EXP2512 external expansion enclosures.
Table 24. Drive options for EXP2512 external expansion enclosures
Part number |
Description |
Maximum quantity supported per one enclosure |
3.5" NL SAS HS HDDs |
00NC555 |
2TB 7,200 rpm 6Gb SAS NL 3.5" HDD |
12 |
00NC557 |
3TB 7,200 rpm 6Gb SAS NL 3.5" HDD |
12 |
00NC559 |
4TB 7,200 rpm 6Gb SAS NL 3.5" HDD |
12 |
The following table lists the hard disk drives that are supported by EXP2524 external expansion enclosures.
Table 25. Drive options for EXP2524 external expansion enclosures
Part number |
Description |
Maximum quantity supported per one enclosure |
2.5" NL SAS HS HDDs |
00NC571 |
1TB 7,200 rpm 6Gb SAS NL 2.5" HDD |
24 |
2.5" SAS HS HDDs |
00NC561 |
146GB 15,000 rpm 6Gb SAS 2.5" HDD |
24 |
00NC563 |
300GB 15,000 rpm 6Gb SAS 2.5" HDD |
24 |
00NC565 |
600GB 10,000 rpm 6Gb SAS 2.5" HDD |
24 |
00NC567 |
900GB 10,000 rpm 6Gb SAS 2.5" HDD |
24 |
00NC569 |
1.2TB 10,000 rpm 6Gb SAS 2.5" HDD |
24 |
2.5" SAS HS SSDs |
00NC573 |
200GB 6Gb SAS 2.5" SSD |
24 |
00NC575 |
400GB 6Gb SAS 2.5" SSD |
24 |
External disk storage systems
The following table lists the external storage systems that are supported by the server and can be ordered through System x sales channel. The server may support other disk systems that are not listed in this table.
For more information, see the IBM System Storage Interoperability Center at http://www.ibm.com/systems/support/storage/ssic.
Table 26. External disk storage systems
Part number |
Description |
2071CU2 |
IBM Storwize V3500 LFF Dual Control Enclosure |
2071CU3 |
IBM Storwize V3500 SFF Dual Control Enclosure |
6099L2C |
IBM Storwize V3700 3.5-inch Storage Controller Unit |
6099S2C |
IBM Storwize V3700 2.5-inch Storage Controller Unit |
6099T2C |
IBM Storwize V3700 2.5-inch DC Storage Controller Unit |
6194L2C |
IBM Storwize V5000 LFF Control Enclosure |
6194LEU |
IBM Storwize V5000 LFF Expansion Enclosure |
6194S2C |
IBM Storwize V5000 SFF Control Enclosure |
6194SEU |
IBM Storwize V5000 SFF Expansion Enclosure |
6195SC5 |
IBM Storwize V7000 2.5-inch Storage Controller Unit |
6195LEF |
IBM Storwize V7000 3.5-inch Storage Expansion Unit |
6195SEF |
IBM Storwize V7000 2.5-inch Storage Expansion Unit |
For more information, see the list of Lenovo Press Product Guides in the System Storage category:
http://lenovopress.com/systemx/externalstorage
External backup units
The server supports the external backup attachment options that are listed in the following table.
Table 27. External backup options
Part number |
Description |
External tape expansion enclosures for internal tape drives |
87651UX |
1U Tape Drive Enclosure |
87651NX |
1U Tape Drive Enclosure (with Nema 5-15P LineCord) |
Tape enclosure adapters (with cables) |
44E8869 |
USB Enclosure Adapter Kit |
40K2599 |
SAS Enclosure Adapter Kit |
Internal backup drives supported by external tape enclosures |
00D2786 |
RDX Internal USB 3.0 Dock with 320GB Cartridge |
00D2787 |
RDX Internal USB 3.0 Dock with 500GB Cartridge |
00D2788 |
RDX Internal USB 3.0 Dock with 1TB Cartridge |
49Y9898 |
Half High LTO Gen 5 Internal SAS Tape Drive |
00D8924 |
Half High LTO Ultrium Gen 6 Internal SAS Tape Drive |
External backup units* |
362532Y |
RDX External USB 3.0 Dock with 320GB Cartridge |
362550Y |
RDX External USB 3.0 Dock with 500GB Cartridge |
36251TY |
RDX External USB 3.0 Dock with 1TB Cartridge |
3628L5X |
Half High LTO Gen 5 External SAS Tape Drive (with US line cord) |
3628N5X |
Half High LTO Gen 5 External SAS Tape Drive (without line cord) |
* These external tape drives can be ordered through the System x sales channel. The server might support other tape drives that are not listed in this table. See the System Storage Interoperation Center (SSIC) for further information.
For more information, see the list of Lenovo Press Product Guides in the Backup units category:
http://lenovopress.com/systemx/tape
Top-of-rack Ethernet switches
The server supports the top-of-rack Ethernet switches from Lenovo that are listed in the following table.
Table 28. Top-of-rack switches
Part number |
Description |
1 Gb top-of-rack switches |
7159BAX |
Lenovo RackSwitch G7028 (Rear to Front) |
7159CAX |
Lenovo RackSwitch G7052 (Rear to Front) |
715952F |
Lenovo RackSwitch G8052 (Front to Rear) |
7159G52 |
Lenovo RackSwitch G8052 (Rear to Front) |
10 Gb top-of-rack switches |
7159BF7 |
Lenovo RackSwitch G8124E (Front to Rear) |
7159BR6 |
Lenovo RackSwitch G8124E (Rear to Front) |
715964F |
Lenovo RackSwitch G8264 (Front to Rear) |
7159G64 |
Lenovo RackSwitch G8264 (Rear to Front) |
7159DFX |
Lenovo RackSwitch G8264CS (Front to Rear) |
7159DRX |
Lenovo RackSwitch G8264CS (Rear to Front) |
7159CFV |
Lenovo RackSwitch G8272 (Front to Rear) |
7159CRW |
Lenovo RackSwitch G8272 (Rear to Front) |
7159GR5 |
Lenovo RackSwitch G8296 (Front to Rear) |
7159GR6 |
Lenovo RackSwitch G8296 (Rear to Front) |
40 Gb top-of-rack switches |
7159BFX |
Lenovo RackSwitch G8332 (Front to Rear) |
7159BRX |
Lenovo RackSwitch G8332 (Rear to Front) |
For more information, see the list of Lenovo Press Product Guides in the Top-of-rack switches category:
http://lenovopress.com/systemx/tor
Uninterruptible power supply units
The server supports attachments to the uninterruptible power supply (UPS) units that are listed in the following table.
Table 29. Uninterruptible power supply units
Part number |
Description |
Rack-mounted or tower UPS units |
55941AX |
RT1.5kVA 2U Rack or Tower UPS (100-125VAC) |
55941KX |
RT1.5kVA 2U Rack or Tower UPS (200-240VAC) |
55942AX |
RT2.2kVA 2U Rack or Tower UPS (100-125VAC) |
55942KX |
RT2.2kVA 2U Rack or Tower UPS (200-240VAC) |
55943AX |
RT3kVA 2U Rack or Tower UPS (100-125VAC) |
55943KX |
RT3kVA 2U Rack or Tower UPS (200-240VAC) |
55945KX |
RT5kVA 3U Rack or Tower UPS (200-240VAC) |
55946KX |
RT6kVA 3U Rack or Tower UPS (200-240VAC) |
55948KX |
RT8kVA 6U Rack or Tower UPS (200-240VAC) |
55949KX |
RT11kVA 6U Rack or Tower UPS (200-240VAC) |
55948PX |
RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
55949PX |
RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
Rack-mounted UPS units |
53951AX |
1500VA LCD 2U Rack UPS (100V/120V) |
53951KX |
1500VA LCD 2U Rack UPS (230V) |
53952AX |
2200VA LCD 2U Rack UPS (100V/120V) |
53952KX |
2200VA LCD 2U Rack UPS (230V) |
53953AX |
3000VA LCD 3U Rack UPS (100 V/120 V) |
53953JX |
3000VA LCD 3U Rack UPS (200 V/208 V) |
53956AX |
6000VA LCD 4U Rack UPS (200 V/208 V) |
53956KX |
6000VA LCD 4U Rack UPS (230 V) |
53959KX |
11000VA LCD 5U Rack UPS (200V/208V/230V) |
For more information, see the list of Lenovo Press Product Guides in the Power infrastructure category:
http://lenovopress.com/systemx/power
Power distribution units
The server supports attachments to the power distribution units (PDUs) that are listed in the following table.
Table 30. Power distribution units
Part number |
Description |
Switched and Monitored PDUs |
46M4002 |
1U 9 C19/3 C13 Active Energy Manager DPI® PDU |
46M4003 |
1U 9 C19/3 C13 Active Energy Manager 60A 3 Phase PDU |
46M4004 |
1U 12 C13 Active Energy Manager DPI PDU |
46M4005 |
1U 12 C13 Active Energy Manager 60A 3 Phase PDU |
46M4167 |
1U 9 C19/3 C13 Switched and Monitored 30A 3 Phase PDU |
46M4116 |
0U 24 C13 Switched and Monitored 30A PDU |
46M4119 |
0U 24 C13 Switched and Monitored 32A PDU |
46M4134 |
0U 12 C19/12 C13 Switched and Monitored 50A 3 Phase PDU |
46M4137 |
0U 12 C19/12 C13 Switched and Monitored 32A 3 Phase PDU |
Enterprise PDUs |
71762MX |
Ultra Density Enterprise PDU C19 PDU+ (WW) |
71762NX |
Ultra Density Enterprise PDU C19 PDU (WW) |
71763MU |
Ultra Density Enterprise PDU C19 3 phase 60A PDU+ (NA) |
71763NU |
Ultra Density Enterprise PDU C19 3 phase 60A PDU (NA) |
39M2816 |
DPI C13 Enterprise PDU without linecord |
39Y8923 |
DPI 60A Three Phase C19 Enterprise PDU with IEC309 3P+G (208 V) fixed power cord |
39Y8941 |
DPI Single Phase C13 Enterprise PDU without power cord |
39Y8948 |
DPI Single Phase C19 Enterprise PDU without power cord |
Front-End PDUs |
39Y8934 |
DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd connector |
39Y8935 |
DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd connector |
39Y8938 |
30amp/125V Front-end PDU with NEMA L5-30P connector |
39Y8939 |
30amp/250V Front-end PDU with NEMA L6-30P connector |
39Y8940 |
60amp/250V Front-end PDU with IEC 309 60A 2P+N+Gnd connector |
Universal PDUs |
39Y8951 |
DPI Universal Rack PDU w/ US LV and HV power cords |
39Y8952 |
DPI Universal Rack PDU w/ CEE7-VII Europe LC |
39Y8953 |
DPI Universal Rack PDU w/ Denmark LC |
39Y8954 |
DPI Universal Rack PDU w/ Israel LC |
39Y8955 |
DPI Universal Rack PDU w/Italy LC |
39Y8956 |
DPI Universal Rack PDU w/South Africa LC |
39Y8957 |
DPI Universal Rack PDU w/UK LC |
39Y8958 |
DPI Universal Rack PDU with AS/NZ LC |
39Y8959 |
DPI Universal Rack PDU w/China LC |
39Y8962 |
DPI Universal Rack PDU (Argentina) |
39Y8960 |
DPI Universal Rack PDU (Brazil) |
39Y8961 |
DPI Universal Rack PDU (India) |
0U Basic PDUs |
46M4122 |
0U 24 C13 16A 3 Phase PDU |
46M4125 |
0U 24 C13 30A 3 Phase PDU |
46M4128 |
0U 24 C13 30A PDU |
46M4131 |
0U 24 C13 32A PDU |
46M4140 |
0U 12 C19/12 C13 60A 3 Phase PDU |
46M4143 |
0U 12 C19/12 C13 32A 3 Phase PDU |
For more information, see the list of Lenovo Press Product Guides in the Power infrastructure category:
http://lenovopress.com/systemx/power
Racks cabinets
The server supports the rack cabinets that are listed in the following table. One of the tower-to-rack conversion kits is required for the server to be installed in the rack.
Table 31. Rack cabinets
Part number |
Description |
00J6353 |
Tower to 5U Rack Conversion Kit for System x3100 M5 (for systems with hot-swap power supplies) |
69Y5182 |
Tower to 4U Rack Conversion Kit for System x3100 M5 (for systems with fixed power supplies) |
93072PX |
25U Static S2 Standard Rack |
93072RX |
25U Standard Rack |
93074RX |
42U Standard Rack |
93074XX |
42U Standard Rack Extension |
93084EX |
42U Enterprise Expansion Rack |
93084PX |
42U Enterprise Rack |
93604EX |
42U 1200 mm Deep Dynamic Expansion Rack |
93604PX |
42U 1200 mm Deep Dynamic Rack |
93614EX |
42U 1200 mm Deep Static Expansion Rack |
93614PX |
42U 1200 mm Deep Static Rack |
93624EX |
47U 1200 mm Deep Static Expansion Rack |
93624PX |
47U 1200 mm Deep Static Rack |
For more information, see the list of Lenovo Press Product Guides in the Rack cabinets and options category:
http://lenovopress.com/systemx/rack
Rack options
The server supports the rack console switches and monitor kits that are listed in the following table.
Table 32. Rack options
Part number |
Feature code |
Description |
Monitor kits and keyboard trays |
17238BX |
1723HC1 fc A3EK |
1U 18.5" Standard Console |
17238EX |
1723HC1 fc A3EL |
1U 18.5" Enhanced Media Console |
172317X |
1723HC1 fc 0051 |
1U 17in Flat Panel Console Kit |
172319X |
1723HC1 fc 0052 |
1U 19in Flat Panel Console Kit |
Console switches |
3858D3X |
3858HC1 fc A4X1 |
Avocent Universal Management Gateway 6000 |
1754D2X |
1754HC2 fc 6695 |
Global 4x2x32 Console Manager (GCM32) |
1754D1X |
1754HC1 fc 6694 |
Global 2x2x16 Console Manager (GCM16) |
1754A2X |
1754HC4 fc 0726 |
Local 2x16 Console Manager (LCM16) |
1754A1X |
1754HC3 fc 0725 |
Local 1x8 Console Manager (LCM8) |
Console cables |
00AK142 |
A4X4 |
UM KVM Module VGA+SD Dual RJ45 |
43V6147 |
3757 |
Single Cable USB Conversion Option (UCO) |
39M2895 |
3756 |
USB Conversion Option (4 Pack UCO) |
39M2897 |
3754 |
Long KVM Conversion Option (4 Pack Long KCO) |
46M5383 |
5341 |
Virtual Media Conversion Option Gen2 (VCO2) |
46M5382 |
5340 |
Serial Conversion Option (SCO) |
For more information, see the list of Lenovo Press Product Guides in the Rack cabinets and options category:
http://lenovopress.com/systemx/rack